Coaxial Surge Protector N Female to N Female, DC to 3 GHz
N Female to Female surge protectors are most commonly installed inline between the donor antenna feeder cable and the equipment patch cable. With an N Female Bulkhead interface, the surge protector can be mounted through a plate. Surge protection is...
See full specifications ↓Available to order online
- OnlineIn stock
- In-storeOut of stock
Orders are dispatched from Victoria.
Call 1300 003 978 to check availability.
- Genuine products with manufacturer warranty
- Fast delivery – dispatched from VIC
- Expert support: 1300 003 978 · Mon–Fri 9am–6pm
- Secure checkout
N Female to Female surge protectors are most commonly installed inline between the donor antenna feeder cable and the equipment patch cable. With an N Female Bulkhead interface, the surge protector can be mounted through a plate. Surge protection is recommended for all roof mounted antenna installations where the risk of a lightning surge is high and the cost associated with equipment damage outweighs the cost to implement a lightning protection system. Consult AS/NZS 1768:2007 risk management process, or talk to your Powertec Project Engineer.
- Suitable for 4G frequencies from DC to 3 GHz
- N Female Bulkhead to N Female interfaces
- Gas discharge tube design
- Ring terminal suitable for 6 mm earth cable
- Requires connection to ground per AS/ASCIF S009.
The implementation of a lightning protection system is recommended in not only protecting the warranty of equipment, but the warranty of any sensitive electrical equipment located in the building. Failure to implement reasonable lightning protection measures may also void insurance policies held by the building owner.
Warranty: 1 year
General
| Brand | Powertec |
|---|---|
| Model / SKU | ACC-BH-00002 |
| Category | RF Surge Protectors |
Warranty
Every product we sell is genuine and covered by the manufacturer's warranty.
Faulty item or warranty claim? Call 1300 003 978 (Mon–Fri 9am–6pm) or email info@tekcart.com.au.
Delivery
- Fast delivery Australia-wide
- Orders are dispatched from Victoria
- Professional installation available in VIC, NSW & ACT — request a quote
Payment
Pay securely at checkout with:
All prices are in Australian dollars and include GST.
Frequently asked questions
Are your products genuine?
Yes. Every product we sell is genuine and covered by the manufacturer's warranty.
Can you install this for me?
Yes. Our certified installation partners supply and install CCTV, alarm and networking systems across Victoria, New South Wales and the ACT. Request a quote.
How much is shipping?
Shipping is calculated at checkout. Orders are dispatched quickly from Victoria. See our delivery information.
This item shows out of stock. What can I do?
Call us on 1300 003 978 to check availability, or leave your email under "Notify me" and we'll tell you when it's back.
Can I get help choosing the right product?
Yes. Call 1300 003 978 (Mon–Fri 9am–6pm) or email info@tekcart.com.au.




Need it installed?
Our technicians supply and install security and networking systems across VIC, NSW & ACT.
Request a quote → 1300 003 978Other Customers also buy:
-
-
{"id":9724060827737,"title":"Coaxial Surge Protector N Female to N Female, DC to 3 GHz","handle":"coaxial-surge-protector-n-female-to-n-female-dc-to-3-ghz","description":"\u003cp\u003eN Female to Female surge protectors are most commonly installed inline between the donor antenna feeder cable and the equipment patch cable. With an N Female Bulkhead interface, the surge protector can be mounted through a plate. Surge protection is recommended for all roof mounted antenna installations where the risk of a lightning surge is high and the cost associated with equipment damage outweighs the cost to implement a lightning protection system. Consult AS\/NZS 1768:2007 risk management process, or talk to your Powertec Project Engineer.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable for 4G frequencies from DC to 3 GHz\u003c\/li\u003e\n\u003cli\u003eN Female Bulkhead to N Female interfaces\u003c\/li\u003e\n\u003cli\u003eGas discharge tube design\u003c\/li\u003e\n\u003cli\u003eRing terminal suitable for 6 mm earth cable\u003c\/li\u003e\n\u003cli\u003eRequires connection to ground per AS\/ASCIF S009.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe implementation of a lightning protection system is recommended in not only protecting the warranty of equipment, but the warranty of any sensitive electrical equipment located in the building. Failure to implement reasonable lightning protection measures may also void insurance policies held by the building owner.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/powertec.com.au\/content\/powertec\/Powertec%20Surge%20Protectors%20Datasheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDatasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eWarranty: 1 year\u003c\/p\u003e","published_at":"2026-11-20T03:18:10+11:00","created_at":"2026-11-20T03:18:09+11:00","vendor":"Powertec","type":"RF Surge Protectors","tags":["PowerTec","tk-sync","tk-sync-powertec"],"price":7840,"price_min":7840,"price_max":7840,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":47908350230617,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"ACC-BH-00002","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Coaxial Surge Protector N Female to N Female, DC to 3 GHz","public_title":null,"options":["Default Title"],"price":7840,"weight":130,"compare_at_price":null,"inventory_management":"shopify","barcode":"9337692000119","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f__55269.1716779835.jpg?v=1795105091","\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f-02__44392.1716779835.jpg?v=1795105091","\/\/tekcart.com.au\/cdn\/shop\/files\/Powertec-RF-Surge-Protector-Arrester-N-Female__30373.1715304130.jpg?v=1795105091"],"featured_image":"\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f__55269.1716779835.jpg?v=1795105091","options":["Title"],"media":[{"alt":"Coaxial Surge Protector N Female to N Female, DC to 3 GHz","id":41844553089113,"position":1,"preview_image":{"aspect_ratio":1.2,"height":1000,"width":1200,"src":"\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f__55269.1716779835.jpg?v=1795105091"},"aspect_ratio":1.2,"height":1000,"media_type":"image","src":"\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f__55269.1716779835.jpg?v=1795105091","width":1200},{"alt":"Coaxial Surge Protector N Female to N Female, DC to 3 GHz","id":41844553121881,"position":2,"preview_image":{"aspect_ratio":1.2,"height":1000,"width":1200,"src":"\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f-02__44392.1716779835.jpg?v=1795105091"},"aspect_ratio":1.2,"height":1000,"media_type":"image","src":"\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f-02__44392.1716779835.jpg?v=1795105091","width":1200},{"alt":"Coaxial Surge Protector N Female to N Female, DC to 3 GHz","id":41844553154649,"position":3,"preview_image":{"aspect_ratio":1.0,"height":1830,"width":1830,"src":"\/\/tekcart.com.au\/cdn\/shop\/files\/Powertec-RF-Surge-Protector-Arrester-N-Female__30373.1715304130.jpg?v=1795105091"},"aspect_ratio":1.0,"height":1830,"media_type":"image","src":"\/\/tekcart.com.au\/cdn\/shop\/files\/Powertec-RF-Surge-Protector-Arrester-N-Female__30373.1715304130.jpg?v=1795105091","width":1830}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eN Female to Female surge protectors are most commonly installed inline between the donor antenna feeder cable and the equipment patch cable. With an N Female Bulkhead interface, the surge protector can be mounted through a plate. Surge protection is recommended for all roof mounted antenna installations where the risk of a lightning surge is high and the cost associated with equipment damage outweighs the cost to implement a lightning protection system. Consult AS\/NZS 1768:2007 risk management process, or talk to your Powertec Project Engineer.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable for 4G frequencies from DC to 3 GHz\u003c\/li\u003e\n\u003cli\u003eN Female Bulkhead to N Female interfaces\u003c\/li\u003e\n\u003cli\u003eGas discharge tube design\u003c\/li\u003e\n\u003cli\u003eRing terminal suitable for 6 mm earth cable\u003c\/li\u003e\n\u003cli\u003eRequires connection to ground per AS\/ASCIF S009.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe implementation of a lightning protection system is recommended in not only protecting the warranty of equipment, but the warranty of any sensitive electrical equipment located in the building. Failure to implement reasonable lightning protection measures may also void insurance policies held by the building owner.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/powertec.com.au\/content\/powertec\/Powertec%20Surge%20Protectors%20Datasheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDatasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eWarranty: 1 year\u003c\/p\u003e"}
Translation missing: en.products.product.regular_price $20,790.00 -
-
{"id":9724060827737,"title":"Coaxial Surge Protector N Female to N Female, DC to 3 GHz","handle":"coaxial-surge-protector-n-female-to-n-female-dc-to-3-ghz","description":"\u003cp\u003eN Female to Female surge protectors are most commonly installed inline between the donor antenna feeder cable and the equipment patch cable. With an N Female Bulkhead interface, the surge protector can be mounted through a plate. Surge protection is recommended for all roof mounted antenna installations where the risk of a lightning surge is high and the cost associated with equipment damage outweighs the cost to implement a lightning protection system. Consult AS\/NZS 1768:2007 risk management process, or talk to your Powertec Project Engineer.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable for 4G frequencies from DC to 3 GHz\u003c\/li\u003e\n\u003cli\u003eN Female Bulkhead to N Female interfaces\u003c\/li\u003e\n\u003cli\u003eGas discharge tube design\u003c\/li\u003e\n\u003cli\u003eRing terminal suitable for 6 mm earth cable\u003c\/li\u003e\n\u003cli\u003eRequires connection to ground per AS\/ASCIF S009.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe implementation of a lightning protection system is recommended in not only protecting the warranty of equipment, but the warranty of any sensitive electrical equipment located in the building. Failure to implement reasonable lightning protection measures may also void insurance policies held by the building owner.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/powertec.com.au\/content\/powertec\/Powertec%20Surge%20Protectors%20Datasheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDatasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eWarranty: 1 year\u003c\/p\u003e","published_at":"2026-11-20T03:18:10+11:00","created_at":"2026-11-20T03:18:09+11:00","vendor":"Powertec","type":"RF Surge Protectors","tags":["PowerTec","tk-sync","tk-sync-powertec"],"price":7840,"price_min":7840,"price_max":7840,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":47908350230617,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"ACC-BH-00002","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Coaxial Surge Protector N Female to N Female, DC to 3 GHz","public_title":null,"options":["Default Title"],"price":7840,"weight":130,"compare_at_price":null,"inventory_management":"shopify","barcode":"9337692000119","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f__55269.1716779835.jpg?v=1795105091","\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f-02__44392.1716779835.jpg?v=1795105091","\/\/tekcart.com.au\/cdn\/shop\/files\/Powertec-RF-Surge-Protector-Arrester-N-Female__30373.1715304130.jpg?v=1795105091"],"featured_image":"\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f__55269.1716779835.jpg?v=1795105091","options":["Title"],"media":[{"alt":"Coaxial Surge Protector N Female to N Female, DC to 3 GHz","id":41844553089113,"position":1,"preview_image":{"aspect_ratio":1.2,"height":1000,"width":1200,"src":"\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f__55269.1716779835.jpg?v=1795105091"},"aspect_ratio":1.2,"height":1000,"media_type":"image","src":"\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f__55269.1716779835.jpg?v=1795105091","width":1200},{"alt":"Coaxial Surge Protector N Female to N Female, DC to 3 GHz","id":41844553121881,"position":2,"preview_image":{"aspect_ratio":1.2,"height":1000,"width":1200,"src":"\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f-02__44392.1716779835.jpg?v=1795105091"},"aspect_ratio":1.2,"height":1000,"media_type":"image","src":"\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f-02__44392.1716779835.jpg?v=1795105091","width":1200},{"alt":"Coaxial Surge Protector N Female to N Female, DC to 3 GHz","id":41844553154649,"position":3,"preview_image":{"aspect_ratio":1.0,"height":1830,"width":1830,"src":"\/\/tekcart.com.au\/cdn\/shop\/files\/Powertec-RF-Surge-Protector-Arrester-N-Female__30373.1715304130.jpg?v=1795105091"},"aspect_ratio":1.0,"height":1830,"media_type":"image","src":"\/\/tekcart.com.au\/cdn\/shop\/files\/Powertec-RF-Surge-Protector-Arrester-N-Female__30373.1715304130.jpg?v=1795105091","width":1830}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eN Female to Female surge protectors are most commonly installed inline between the donor antenna feeder cable and the equipment patch cable. With an N Female Bulkhead interface, the surge protector can be mounted through a plate. Surge protection is recommended for all roof mounted antenna installations where the risk of a lightning surge is high and the cost associated with equipment damage outweighs the cost to implement a lightning protection system. Consult AS\/NZS 1768:2007 risk management process, or talk to your Powertec Project Engineer.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable for 4G frequencies from DC to 3 GHz\u003c\/li\u003e\n\u003cli\u003eN Female Bulkhead to N Female interfaces\u003c\/li\u003e\n\u003cli\u003eGas discharge tube design\u003c\/li\u003e\n\u003cli\u003eRing terminal suitable for 6 mm earth cable\u003c\/li\u003e\n\u003cli\u003eRequires connection to ground per AS\/ASCIF S009.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe implementation of a lightning protection system is recommended in not only protecting the warranty of equipment, but the warranty of any sensitive electrical equipment located in the building. Failure to implement reasonable lightning protection measures may also void insurance policies held by the building owner.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/powertec.com.au\/content\/powertec\/Powertec%20Surge%20Protectors%20Datasheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDatasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eWarranty: 1 year\u003c\/p\u003e"}
Translation missing: en.products.product.regular_price $900.90 -
-
{"id":9724060827737,"title":"Coaxial Surge Protector N Female to N Female, DC to 3 GHz","handle":"coaxial-surge-protector-n-female-to-n-female-dc-to-3-ghz","description":"\u003cp\u003eN Female to Female surge protectors are most commonly installed inline between the donor antenna feeder cable and the equipment patch cable. With an N Female Bulkhead interface, the surge protector can be mounted through a plate. Surge protection is recommended for all roof mounted antenna installations where the risk of a lightning surge is high and the cost associated with equipment damage outweighs the cost to implement a lightning protection system. Consult AS\/NZS 1768:2007 risk management process, or talk to your Powertec Project Engineer.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable for 4G frequencies from DC to 3 GHz\u003c\/li\u003e\n\u003cli\u003eN Female Bulkhead to N Female interfaces\u003c\/li\u003e\n\u003cli\u003eGas discharge tube design\u003c\/li\u003e\n\u003cli\u003eRing terminal suitable for 6 mm earth cable\u003c\/li\u003e\n\u003cli\u003eRequires connection to ground per AS\/ASCIF S009.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe implementation of a lightning protection system is recommended in not only protecting the warranty of equipment, but the warranty of any sensitive electrical equipment located in the building. Failure to implement reasonable lightning protection measures may also void insurance policies held by the building owner.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/powertec.com.au\/content\/powertec\/Powertec%20Surge%20Protectors%20Datasheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDatasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eWarranty: 1 year\u003c\/p\u003e","published_at":"2026-11-20T03:18:10+11:00","created_at":"2026-11-20T03:18:09+11:00","vendor":"Powertec","type":"RF Surge Protectors","tags":["PowerTec","tk-sync","tk-sync-powertec"],"price":7840,"price_min":7840,"price_max":7840,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":47908350230617,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"ACC-BH-00002","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Coaxial Surge Protector N Female to N Female, DC to 3 GHz","public_title":null,"options":["Default Title"],"price":7840,"weight":130,"compare_at_price":null,"inventory_management":"shopify","barcode":"9337692000119","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f__55269.1716779835.jpg?v=1795105091","\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f-02__44392.1716779835.jpg?v=1795105091","\/\/tekcart.com.au\/cdn\/shop\/files\/Powertec-RF-Surge-Protector-Arrester-N-Female__30373.1715304130.jpg?v=1795105091"],"featured_image":"\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f__55269.1716779835.jpg?v=1795105091","options":["Title"],"media":[{"alt":"Coaxial Surge Protector N Female to N Female, DC to 3 GHz","id":41844553089113,"position":1,"preview_image":{"aspect_ratio":1.2,"height":1000,"width":1200,"src":"\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f__55269.1716779835.jpg?v=1795105091"},"aspect_ratio":1.2,"height":1000,"media_type":"image","src":"\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f__55269.1716779835.jpg?v=1795105091","width":1200},{"alt":"Coaxial Surge Protector N Female to N Female, DC to 3 GHz","id":41844553121881,"position":2,"preview_image":{"aspect_ratio":1.2,"height":1000,"width":1200,"src":"\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f-02__44392.1716779835.jpg?v=1795105091"},"aspect_ratio":1.2,"height":1000,"media_type":"image","src":"\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f-02__44392.1716779835.jpg?v=1795105091","width":1200},{"alt":"Coaxial Surge Protector N Female to N Female, DC to 3 GHz","id":41844553154649,"position":3,"preview_image":{"aspect_ratio":1.0,"height":1830,"width":1830,"src":"\/\/tekcart.com.au\/cdn\/shop\/files\/Powertec-RF-Surge-Protector-Arrester-N-Female__30373.1715304130.jpg?v=1795105091"},"aspect_ratio":1.0,"height":1830,"media_type":"image","src":"\/\/tekcart.com.au\/cdn\/shop\/files\/Powertec-RF-Surge-Protector-Arrester-N-Female__30373.1715304130.jpg?v=1795105091","width":1830}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eN Female to Female surge protectors are most commonly installed inline between the donor antenna feeder cable and the equipment patch cable. With an N Female Bulkhead interface, the surge protector can be mounted through a plate. Surge protection is recommended for all roof mounted antenna installations where the risk of a lightning surge is high and the cost associated with equipment damage outweighs the cost to implement a lightning protection system. Consult AS\/NZS 1768:2007 risk management process, or talk to your Powertec Project Engineer.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable for 4G frequencies from DC to 3 GHz\u003c\/li\u003e\n\u003cli\u003eN Female Bulkhead to N Female interfaces\u003c\/li\u003e\n\u003cli\u003eGas discharge tube design\u003c\/li\u003e\n\u003cli\u003eRing terminal suitable for 6 mm earth cable\u003c\/li\u003e\n\u003cli\u003eRequires connection to ground per AS\/ASCIF S009.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe implementation of a lightning protection system is recommended in not only protecting the warranty of equipment, but the warranty of any sensitive electrical equipment located in the building. Failure to implement reasonable lightning protection measures may also void insurance policies held by the building owner.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/powertec.com.au\/content\/powertec\/Powertec%20Surge%20Protectors%20Datasheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDatasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eWarranty: 1 year\u003c\/p\u003e"}
Translation missing: en.products.product.regular_price $7,095.00 -
-
{"id":9724060827737,"title":"Coaxial Surge Protector N Female to N Female, DC to 3 GHz","handle":"coaxial-surge-protector-n-female-to-n-female-dc-to-3-ghz","description":"\u003cp\u003eN Female to Female surge protectors are most commonly installed inline between the donor antenna feeder cable and the equipment patch cable. With an N Female Bulkhead interface, the surge protector can be mounted through a plate. Surge protection is recommended for all roof mounted antenna installations where the risk of a lightning surge is high and the cost associated with equipment damage outweighs the cost to implement a lightning protection system. Consult AS\/NZS 1768:2007 risk management process, or talk to your Powertec Project Engineer.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable for 4G frequencies from DC to 3 GHz\u003c\/li\u003e\n\u003cli\u003eN Female Bulkhead to N Female interfaces\u003c\/li\u003e\n\u003cli\u003eGas discharge tube design\u003c\/li\u003e\n\u003cli\u003eRing terminal suitable for 6 mm earth cable\u003c\/li\u003e\n\u003cli\u003eRequires connection to ground per AS\/ASCIF S009.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe implementation of a lightning protection system is recommended in not only protecting the warranty of equipment, but the warranty of any sensitive electrical equipment located in the building. Failure to implement reasonable lightning protection measures may also void insurance policies held by the building owner.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/powertec.com.au\/content\/powertec\/Powertec%20Surge%20Protectors%20Datasheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDatasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eWarranty: 1 year\u003c\/p\u003e","published_at":"2026-11-20T03:18:10+11:00","created_at":"2026-11-20T03:18:09+11:00","vendor":"Powertec","type":"RF Surge Protectors","tags":["PowerTec","tk-sync","tk-sync-powertec"],"price":7840,"price_min":7840,"price_max":7840,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":47908350230617,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"ACC-BH-00002","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Coaxial Surge Protector N Female to N Female, DC to 3 GHz","public_title":null,"options":["Default Title"],"price":7840,"weight":130,"compare_at_price":null,"inventory_management":"shopify","barcode":"9337692000119","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f__55269.1716779835.jpg?v=1795105091","\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f-02__44392.1716779835.jpg?v=1795105091","\/\/tekcart.com.au\/cdn\/shop\/files\/Powertec-RF-Surge-Protector-Arrester-N-Female__30373.1715304130.jpg?v=1795105091"],"featured_image":"\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f__55269.1716779835.jpg?v=1795105091","options":["Title"],"media":[{"alt":"Coaxial Surge Protector N Female to N Female, DC to 3 GHz","id":41844553089113,"position":1,"preview_image":{"aspect_ratio":1.2,"height":1000,"width":1200,"src":"\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f__55269.1716779835.jpg?v=1795105091"},"aspect_ratio":1.2,"height":1000,"media_type":"image","src":"\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f__55269.1716779835.jpg?v=1795105091","width":1200},{"alt":"Coaxial Surge Protector N Female to N Female, DC to 3 GHz","id":41844553121881,"position":2,"preview_image":{"aspect_ratio":1.2,"height":1000,"width":1200,"src":"\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f-02__44392.1716779835.jpg?v=1795105091"},"aspect_ratio":1.2,"height":1000,"media_type":"image","src":"\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f-02__44392.1716779835.jpg?v=1795105091","width":1200},{"alt":"Coaxial Surge Protector N Female to N Female, DC to 3 GHz","id":41844553154649,"position":3,"preview_image":{"aspect_ratio":1.0,"height":1830,"width":1830,"src":"\/\/tekcart.com.au\/cdn\/shop\/files\/Powertec-RF-Surge-Protector-Arrester-N-Female__30373.1715304130.jpg?v=1795105091"},"aspect_ratio":1.0,"height":1830,"media_type":"image","src":"\/\/tekcart.com.au\/cdn\/shop\/files\/Powertec-RF-Surge-Protector-Arrester-N-Female__30373.1715304130.jpg?v=1795105091","width":1830}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eN Female to Female surge protectors are most commonly installed inline between the donor antenna feeder cable and the equipment patch cable. With an N Female Bulkhead interface, the surge protector can be mounted through a plate. Surge protection is recommended for all roof mounted antenna installations where the risk of a lightning surge is high and the cost associated with equipment damage outweighs the cost to implement a lightning protection system. Consult AS\/NZS 1768:2007 risk management process, or talk to your Powertec Project Engineer.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable for 4G frequencies from DC to 3 GHz\u003c\/li\u003e\n\u003cli\u003eN Female Bulkhead to N Female interfaces\u003c\/li\u003e\n\u003cli\u003eGas discharge tube design\u003c\/li\u003e\n\u003cli\u003eRing terminal suitable for 6 mm earth cable\u003c\/li\u003e\n\u003cli\u003eRequires connection to ground per AS\/ASCIF S009.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe implementation of a lightning protection system is recommended in not only protecting the warranty of equipment, but the warranty of any sensitive electrical equipment located in the building. Failure to implement reasonable lightning protection measures may also void insurance policies held by the building owner.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/powertec.com.au\/content\/powertec\/Powertec%20Surge%20Protectors%20Datasheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDatasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eWarranty: 1 year\u003c\/p\u003e"}
Translation missing: en.products.product.regular_price $72.60 -
-
{"id":9724060827737,"title":"Coaxial Surge Protector N Female to N Female, DC to 3 GHz","handle":"coaxial-surge-protector-n-female-to-n-female-dc-to-3-ghz","description":"\u003cp\u003eN Female to Female surge protectors are most commonly installed inline between the donor antenna feeder cable and the equipment patch cable. With an N Female Bulkhead interface, the surge protector can be mounted through a plate. Surge protection is recommended for all roof mounted antenna installations where the risk of a lightning surge is high and the cost associated with equipment damage outweighs the cost to implement a lightning protection system. Consult AS\/NZS 1768:2007 risk management process, or talk to your Powertec Project Engineer.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable for 4G frequencies from DC to 3 GHz\u003c\/li\u003e\n\u003cli\u003eN Female Bulkhead to N Female interfaces\u003c\/li\u003e\n\u003cli\u003eGas discharge tube design\u003c\/li\u003e\n\u003cli\u003eRing terminal suitable for 6 mm earth cable\u003c\/li\u003e\n\u003cli\u003eRequires connection to ground per AS\/ASCIF S009.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe implementation of a lightning protection system is recommended in not only protecting the warranty of equipment, but the warranty of any sensitive electrical equipment located in the building. Failure to implement reasonable lightning protection measures may also void insurance policies held by the building owner.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/powertec.com.au\/content\/powertec\/Powertec%20Surge%20Protectors%20Datasheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDatasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eWarranty: 1 year\u003c\/p\u003e","published_at":"2026-11-20T03:18:10+11:00","created_at":"2026-11-20T03:18:09+11:00","vendor":"Powertec","type":"RF Surge Protectors","tags":["PowerTec","tk-sync","tk-sync-powertec"],"price":7840,"price_min":7840,"price_max":7840,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":47908350230617,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"ACC-BH-00002","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Coaxial Surge Protector N Female to N Female, DC to 3 GHz","public_title":null,"options":["Default Title"],"price":7840,"weight":130,"compare_at_price":null,"inventory_management":"shopify","barcode":"9337692000119","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f__55269.1716779835.jpg?v=1795105091","\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f-02__44392.1716779835.jpg?v=1795105091","\/\/tekcart.com.au\/cdn\/shop\/files\/Powertec-RF-Surge-Protector-Arrester-N-Female__30373.1715304130.jpg?v=1795105091"],"featured_image":"\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f__55269.1716779835.jpg?v=1795105091","options":["Title"],"media":[{"alt":"Coaxial Surge Protector N Female to N Female, DC to 3 GHz","id":41844553089113,"position":1,"preview_image":{"aspect_ratio":1.2,"height":1000,"width":1200,"src":"\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f__55269.1716779835.jpg?v=1795105091"},"aspect_ratio":1.2,"height":1000,"media_type":"image","src":"\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f__55269.1716779835.jpg?v=1795105091","width":1200},{"alt":"Coaxial Surge Protector N Female to N Female, DC to 3 GHz","id":41844553121881,"position":2,"preview_image":{"aspect_ratio":1.2,"height":1000,"width":1200,"src":"\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f-02__44392.1716779835.jpg?v=1795105091"},"aspect_ratio":1.2,"height":1000,"media_type":"image","src":"\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f-02__44392.1716779835.jpg?v=1795105091","width":1200},{"alt":"Coaxial Surge Protector N Female to N Female, DC to 3 GHz","id":41844553154649,"position":3,"preview_image":{"aspect_ratio":1.0,"height":1830,"width":1830,"src":"\/\/tekcart.com.au\/cdn\/shop\/files\/Powertec-RF-Surge-Protector-Arrester-N-Female__30373.1715304130.jpg?v=1795105091"},"aspect_ratio":1.0,"height":1830,"media_type":"image","src":"\/\/tekcart.com.au\/cdn\/shop\/files\/Powertec-RF-Surge-Protector-Arrester-N-Female__30373.1715304130.jpg?v=1795105091","width":1830}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eN Female to Female surge protectors are most commonly installed inline between the donor antenna feeder cable and the equipment patch cable. With an N Female Bulkhead interface, the surge protector can be mounted through a plate. Surge protection is recommended for all roof mounted antenna installations where the risk of a lightning surge is high and the cost associated with equipment damage outweighs the cost to implement a lightning protection system. Consult AS\/NZS 1768:2007 risk management process, or talk to your Powertec Project Engineer.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable for 4G frequencies from DC to 3 GHz\u003c\/li\u003e\n\u003cli\u003eN Female Bulkhead to N Female interfaces\u003c\/li\u003e\n\u003cli\u003eGas discharge tube design\u003c\/li\u003e\n\u003cli\u003eRing terminal suitable for 6 mm earth cable\u003c\/li\u003e\n\u003cli\u003eRequires connection to ground per AS\/ASCIF S009.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe implementation of a lightning protection system is recommended in not only protecting the warranty of equipment, but the warranty of any sensitive electrical equipment located in the building. Failure to implement reasonable lightning protection measures may also void insurance policies held by the building owner.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/powertec.com.au\/content\/powertec\/Powertec%20Surge%20Protectors%20Datasheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDatasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eWarranty: 1 year\u003c\/p\u003e"}
Translation missing: en.products.product.regular_price $1,187.00 -
-
{"id":9724060827737,"title":"Coaxial Surge Protector N Female to N Female, DC to 3 GHz","handle":"coaxial-surge-protector-n-female-to-n-female-dc-to-3-ghz","description":"\u003cp\u003eN Female to Female surge protectors are most commonly installed inline between the donor antenna feeder cable and the equipment patch cable. With an N Female Bulkhead interface, the surge protector can be mounted through a plate. Surge protection is recommended for all roof mounted antenna installations where the risk of a lightning surge is high and the cost associated with equipment damage outweighs the cost to implement a lightning protection system. Consult AS\/NZS 1768:2007 risk management process, or talk to your Powertec Project Engineer.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable for 4G frequencies from DC to 3 GHz\u003c\/li\u003e\n\u003cli\u003eN Female Bulkhead to N Female interfaces\u003c\/li\u003e\n\u003cli\u003eGas discharge tube design\u003c\/li\u003e\n\u003cli\u003eRing terminal suitable for 6 mm earth cable\u003c\/li\u003e\n\u003cli\u003eRequires connection to ground per AS\/ASCIF S009.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe implementation of a lightning protection system is recommended in not only protecting the warranty of equipment, but the warranty of any sensitive electrical equipment located in the building. Failure to implement reasonable lightning protection measures may also void insurance policies held by the building owner.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/powertec.com.au\/content\/powertec\/Powertec%20Surge%20Protectors%20Datasheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDatasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eWarranty: 1 year\u003c\/p\u003e","published_at":"2026-11-20T03:18:10+11:00","created_at":"2026-11-20T03:18:09+11:00","vendor":"Powertec","type":"RF Surge Protectors","tags":["PowerTec","tk-sync","tk-sync-powertec"],"price":7840,"price_min":7840,"price_max":7840,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":47908350230617,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"ACC-BH-00002","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Coaxial Surge Protector N Female to N Female, DC to 3 GHz","public_title":null,"options":["Default Title"],"price":7840,"weight":130,"compare_at_price":null,"inventory_management":"shopify","barcode":"9337692000119","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f__55269.1716779835.jpg?v=1795105091","\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f-02__44392.1716779835.jpg?v=1795105091","\/\/tekcart.com.au\/cdn\/shop\/files\/Powertec-RF-Surge-Protector-Arrester-N-Female__30373.1715304130.jpg?v=1795105091"],"featured_image":"\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f__55269.1716779835.jpg?v=1795105091","options":["Title"],"media":[{"alt":"Coaxial Surge Protector N Female to N Female, DC to 3 GHz","id":41844553089113,"position":1,"preview_image":{"aspect_ratio":1.2,"height":1000,"width":1200,"src":"\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f__55269.1716779835.jpg?v=1795105091"},"aspect_ratio":1.2,"height":1000,"media_type":"image","src":"\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f__55269.1716779835.jpg?v=1795105091","width":1200},{"alt":"Coaxial Surge Protector N Female to N Female, DC to 3 GHz","id":41844553121881,"position":2,"preview_image":{"aspect_ratio":1.2,"height":1000,"width":1200,"src":"\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f-02__44392.1716779835.jpg?v=1795105091"},"aspect_ratio":1.2,"height":1000,"media_type":"image","src":"\/\/tekcart.com.au\/cdn\/shop\/files\/ACC-BH-00002_lightning-arrestor-n-f-02__44392.1716779835.jpg?v=1795105091","width":1200},{"alt":"Coaxial Surge Protector N Female to N Female, DC to 3 GHz","id":41844553154649,"position":3,"preview_image":{"aspect_ratio":1.0,"height":1830,"width":1830,"src":"\/\/tekcart.com.au\/cdn\/shop\/files\/Powertec-RF-Surge-Protector-Arrester-N-Female__30373.1715304130.jpg?v=1795105091"},"aspect_ratio":1.0,"height":1830,"media_type":"image","src":"\/\/tekcart.com.au\/cdn\/shop\/files\/Powertec-RF-Surge-Protector-Arrester-N-Female__30373.1715304130.jpg?v=1795105091","width":1830}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eN Female to Female surge protectors are most commonly installed inline between the donor antenna feeder cable and the equipment patch cable. With an N Female Bulkhead interface, the surge protector can be mounted through a plate. Surge protection is recommended for all roof mounted antenna installations where the risk of a lightning surge is high and the cost associated with equipment damage outweighs the cost to implement a lightning protection system. Consult AS\/NZS 1768:2007 risk management process, or talk to your Powertec Project Engineer.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable for 4G frequencies from DC to 3 GHz\u003c\/li\u003e\n\u003cli\u003eN Female Bulkhead to N Female interfaces\u003c\/li\u003e\n\u003cli\u003eGas discharge tube design\u003c\/li\u003e\n\u003cli\u003eRing terminal suitable for 6 mm earth cable\u003c\/li\u003e\n\u003cli\u003eRequires connection to ground per AS\/ASCIF S009.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe implementation of a lightning protection system is recommended in not only protecting the warranty of equipment, but the warranty of any sensitive electrical equipment located in the building. Failure to implement reasonable lightning protection measures may also void insurance policies held by the building owner.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/powertec.com.au\/content\/powertec\/Powertec%20Surge%20Protectors%20Datasheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDatasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eWarranty: 1 year\u003c\/p\u003e"}
Translation missing: en.products.product.regular_price $159.00


