Dahua CS4010-8GT-110 10-Port Cloud Managed Desktop Gigabit Switch with 8-Port POE
10-Port Cloud Managed Desktop Gigabit Switch with 8-Port PoE Key Features 8 × RJ-45 Gigabit PoE ports, 2 × RJ-45 Gigabit uplink ports · 110 W total PoE budget IEEE 802.3af/at on all PoE ports · IEEE 802.3bt support on...
See full specifications ↓Available to order online
- OnlineIn stock
- In-storeOut of stock
Orders are dispatched from Victoria.
Call 1300 003 978 to check availability.
- Genuine products with manufacturer warranty
- Fast delivery – dispatched from VIC
- Expert support: 1300 003 978 · Mon–Fri 9am–6pm
- Secure checkout
10-Port Cloud Managed Desktop Gigabit Switch with 8-Port PoE
Key Features
-
8 × RJ-45 Gigabit PoE ports, 2 × RJ-45 Gigabit uplink ports
-
110 W total PoE budget
-
IEEE 802.3af/at on all PoE ports
-
IEEE 802.3bt support on Ports 1–2 (red ports)
-
-
DIP switch for fast mode switching:
-
Cloud-Managed / Unmanaged Mode
-
PoE Watchdog
-
Long-Distance PoE
-
-
Wide operating temperature: –10 °C to +55 °C
-
Supports VLAN, STP, RSTP, and link aggregation
-
Web-managed and centralised cloud management via DoLynk App
-
Easy configuration with auto network detection and system setup
- Datasheet
Basic Specifications
-
Switching Layer: Layer 2
-
Switching Capacity: 20 Gbps
-
Packet Forwarding Rate: 14.88 Mpps
Port Configuration
-
Ports 1–8: 8 × RJ-45 10/100/1000 Mbps (PoE)
-
Ports 9–10: 2 × RJ-45 10/100/1000 Mbps (Gigabit uplink)
Environmental Specifications
-
Operating Temperature: –10 °C to +55 °C (+14 °F to +131 °F)
-
Operating Humidity: 10%–90% RH (non-condensing)
-
Storage Temperature: –40 °C to +75 °C (–40 °F to +167 °F)
-
Storage Humidity: 5%–95% RH (non-condensing)
Power
-
Power Supply: External power adapter, 54 VDC / 2.22 A
-
Power Consumption:
-
Idle: 5.7 W
-
Full Load: 115 W
-
PoE Specifications
-
PoE Support: Yes
-
PoE Protocols: IEEE 802.3af / IEEE 802.3at / Hi-PoE / IEEE 802.3bt
-
PoE Output Power:
-
Ports 1–2: ≤ 90 W per port
-
Ports 3–8: ≤ 30 W per port
-
Total PoE Budget: ≤ 110 W
-
-
PoE Power Management:
-
PoE power consumption management
-
PoE power on/off
-
Automatic PoE shutdown on overload detection
-
-
PoE Pin Assignment:
-
Ports 1–2:
-
V+: 1, 2, 4, 5
-
V–: 3, 6, 7, 8
-
-
Ports 3–8:
-
V+: 1, 2
-
V–: 3, 6
-
-
-
Long-Distance PoE: Yes
Hardware Features
DIP Switch Functions
-
Managed Mode:
-
ON (default): Local web + cloud management
-
OFF: Unmanaged mode
-
-
PoE Watchdog:
-
Monitors ports 1–8
-
Automatically restarts PoE if no traffic is detected for 2 minutes
-
Only active when Managed Mode is OFF
-
-
Extend Mode:
-
Ports 1–8 support up to 250 m transmission at 10 Mbps
-
Only active when Managed Mode is OFF
-
-
Reset Button: 1
Performance
-
MTBF: 2,482,955 hours
-
Packet Buffer: 4 Mbit
-
Jumbo Frame: 15,360 Bytes
-
MAC Address Table: 8K
-
Supported VLANs: 32
Network Standards
-
IEEE Standards:
-
IEEE 802.3
-
IEEE 802.3u
-
IEEE 802.3x
-
IEEE 802.3ab
-
IEEE 802.3az
-
IEEE 802.3ad
-
Network Features
-
Ethernet Loop Protection: STP, RSTP
-
VLAN: IEEE 802.1Q VLAN
-
Link Aggregation: Static aggregation
-
Port Features:
-
IEEE 802.3x Flow Control
-
Unknown Unicast Suppression
-
Multicast Storm Control
-
Broadcast Storm Control
-
MAC + Port Binding
-
Loop Prevention
-
-
Port Mirroring:
-
Local Port Mirroring
-
N:1 Mirroring
-
-
LLDP Support: Yes
-
DHCP: DHCP Client
-
Security: Port Isolation
Management
-
Management Methods:
-
Web Management
-
Cloud Management
-
-
Monitoring & Maintenance:
-
Logs
-
Fault Alarms
-
Protection
-
ESD Protection:
-
Air Discharge: 8 kV
-
Contact Discharge: 6 kV
-
-
Lightning Protection:
-
Common Mode: 6 kV
-
Differential Mode: 1 kV
-
Physical Specifications
-
Net Weight: 0.36 kg (0.79 lb)
-
Gross Weight: 1.13 kg (2.49 lb)
-
Product Dimensions:
-
184.6 × 103.3 × 27 mm (7.27" × 4.07" × 1.06")
-
-
Packaging Dimensions:
-
252 × 137 × 113 mm (9.92" × 5.39" × 4.45")
-
-
Casing Material: Sheet metal
Installation
-
Mounting Options: Desktop mount, Wall mount
Certifications
-
CE
Packing List
-
1 × User Manual
-
1 × Legal and Regulatory Information
-
1 × Power Adapter
-
1 × Power Cord
Warranty: 3 Year Dahua ANZ Manufacturer Warranty
General
| Brand | Dahua |
|---|---|
| Model / SKU | DH-CS4010-8GT-110 |
| Category | Dahua PoE Switch |
Warranty
Every product we sell is genuine and covered by the manufacturer's warranty.
Faulty item or warranty claim? Call 1300 003 978 (Mon–Fri 9am–6pm) or email info@tekcart.com.au.
Delivery
- Fast delivery Australia-wide
- Orders are dispatched from Victoria
- Professional installation available in VIC, NSW & ACT — request a quote
Payment
Pay securely at checkout with:
All prices are in Australian dollars and include GST.
Frequently asked questions
Are your products genuine?
Yes. Every product we sell is genuine and covered by the manufacturer's warranty.
Can you install this for me?
Yes. Our certified installation partners supply and install CCTV, alarm and networking systems across Victoria, New South Wales and the ACT. Request a quote.
How much is shipping?
Shipping is calculated at checkout. Orders are dispatched quickly from Victoria. See our delivery information.
This item shows out of stock. What can I do?
Call us on 1300 003 978 to check availability, or leave your email under "Notify me" and we'll tell you when it's back.
Can I get help choosing the right product?
Yes. Call 1300 003 978 (Mon–Fri 9am–6pm) or email info@tekcart.com.au.




Need it installed?
Our technicians supply and install security and networking systems across VIC, NSW & ACT.
Request a quote → 1300 003 978Other Customers also buy:
-
-
{"id":8191822069849,"title":"Dahua CS4010-8GT-110 10-Port Cloud Managed Desktop Gigabit Switch with 8-Port POE","handle":"cs4010-8gt-110-dahua-10-port-cloud-managed-desktop-gigabit-switch-with-8-port-poe","description":"\u003ch2 data-start=\"153\" data-end=\"220\"\u003e10-Port Cloud Managed Desktop \u003cstrong data-start=\"186\" data-end=\"197\"\u003eGigabit\u003c\/strong\u003e Switch with 8-Port PoE\u003c\/h2\u003e\n\u003ch3 data-start=\"222\" data-end=\"238\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"239\" data-end=\"804\"\u003e\n\u003cli data-start=\"239\" data-end=\"308\"\u003e\n\u003cp data-start=\"241\" data-end=\"308\"\u003e\u003cstrong data-start=\"241\" data-end=\"272\"\u003e8 × RJ-45 Gigabit PoE ports\u003c\/strong\u003e, \u003cstrong data-start=\"274\" data-end=\"308\"\u003e2 × RJ-45 Gigabit uplink ports\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"309\" data-end=\"432\"\u003e\n\u003cp data-start=\"311\" data-end=\"339\"\u003e\u003cstrong data-start=\"311\" data-end=\"337\"\u003e110 W total PoE budget\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"342\" data-end=\"432\"\u003e\n\u003cli data-start=\"342\" data-end=\"378\"\u003e\n\u003cp data-start=\"344\" data-end=\"378\"\u003eIEEE 802.3af\/at on all PoE ports\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"381\" data-end=\"432\"\u003e\n\u003cp data-start=\"383\" data-end=\"432\"\u003e\u003cstrong data-start=\"383\" data-end=\"432\"\u003eIEEE 802.3bt support on Ports 1–2 (red ports)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"433\" data-end=\"552\"\u003e\n\u003cp data-start=\"435\" data-end=\"474\"\u003e\u003cstrong data-start=\"435\" data-end=\"449\"\u003eDIP switch\u003c\/strong\u003e for fast mode switching:\u003c\/p\u003e\n\u003cul data-start=\"477\" data-end=\"552\"\u003e\n\u003cli data-start=\"477\" data-end=\"511\"\u003e\n\u003cp data-start=\"479\" data-end=\"511\"\u003eCloud-Managed \/ Unmanaged Mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"514\" data-end=\"530\"\u003e\n\u003cp data-start=\"516\" data-end=\"530\"\u003ePoE Watchdog\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"533\" data-end=\"552\"\u003e\n\u003cp data-start=\"535\" data-end=\"552\"\u003eLong-Distance PoE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"553\" data-end=\"603\"\u003e\n\u003cp data-start=\"555\" data-end=\"603\"\u003e\u003cstrong data-start=\"555\" data-end=\"586\"\u003eWide operating temperature:\u003c\/strong\u003e –10 °C to +55 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"604\" data-end=\"660\"\u003e\n\u003cp data-start=\"606\" data-end=\"660\"\u003eSupports \u003cstrong data-start=\"615\" data-end=\"634\"\u003eVLAN, STP, RSTP\u003c\/strong\u003e, and \u003cstrong data-start=\"640\" data-end=\"660\"\u003elink aggregation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"661\" data-end=\"734\"\u003e\n\u003cp data-start=\"663\" data-end=\"734\"\u003e\u003cstrong data-start=\"663\" data-end=\"678\"\u003eWeb-managed\u003c\/strong\u003e and \u003cstrong data-start=\"683\" data-end=\"715\"\u003ecentralised cloud management\u003c\/strong\u003e via \u003cstrong data-start=\"720\" data-end=\"734\"\u003eDoLynk App\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"735\" data-end=\"804\"\u003e\n\u003cp data-start=\"737\" data-end=\"804\"\u003eEasy configuration with \u003cstrong data-start=\"761\" data-end=\"804\"\u003eauto network detection and system setup\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"735\" data-end=\"804\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0047\/9510\/5391\/files\/DH-CS4010-8GT-110_V2_datasheet_20251104.pdf?v=1765923577\"\u003e\u003cstrong data-start=\"761\" data-end=\"804\"\u003eDatasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"806\" data-end=\"809\"\u003e\n\u003ch2 data-start=\"811\" data-end=\"834\"\u003eBasic Specifications\u003c\/h2\u003e\n\u003cul data-start=\"835\" data-end=\"946\"\u003e\n\u003cli data-start=\"835\" data-end=\"867\"\u003e\n\u003cp data-start=\"837\" data-end=\"867\"\u003e\u003cstrong data-start=\"837\" data-end=\"857\"\u003eSwitching Layer:\u003c\/strong\u003e Layer 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"868\" data-end=\"903\"\u003e\n\u003cp data-start=\"870\" data-end=\"903\"\u003e\u003cstrong data-start=\"870\" data-end=\"893\"\u003eSwitching Capacity:\u003c\/strong\u003e 20 Gbps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"904\" data-end=\"946\"\u003e\n\u003cp data-start=\"906\" data-end=\"946\"\u003e\u003cstrong data-start=\"906\" data-end=\"933\"\u003ePacket Forwarding Rate:\u003c\/strong\u003e 14.88 Mpps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"948\" data-end=\"951\"\u003e\n\u003ch2 data-start=\"953\" data-end=\"974\"\u003ePort Configuration\u003c\/h2\u003e\n\u003cul data-start=\"975\" data-end=\"1090\"\u003e\n\u003cli data-start=\"975\" data-end=\"1026\"\u003e\n\u003cp data-start=\"977\" data-end=\"1026\"\u003e\u003cstrong data-start=\"977\" data-end=\"991\"\u003ePorts 1–8:\u003c\/strong\u003e 8 × RJ-45 10\/100\/1000 Mbps (PoE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1027\" data-end=\"1090\"\u003e\n\u003cp data-start=\"1029\" data-end=\"1090\"\u003e\u003cstrong data-start=\"1029\" data-end=\"1044\"\u003ePorts 9–10:\u003c\/strong\u003e 2 × RJ-45 10\/100\/1000 Mbps (Gigabit uplink)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1092\" data-end=\"1095\"\u003e\n\u003ch2 data-start=\"1097\" data-end=\"1128\"\u003eEnvironmental Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1129\" data-end=\"1371\"\u003e\n\u003cli data-start=\"1129\" data-end=\"1196\"\u003e\n\u003cp data-start=\"1131\" data-end=\"1196\"\u003e\u003cstrong data-start=\"1131\" data-end=\"1157\"\u003eOperating Temperature:\u003c\/strong\u003e –10 °C to +55 °C (+14 °F to +131 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1197\" data-end=\"1252\"\u003e\n\u003cp data-start=\"1199\" data-end=\"1252\"\u003e\u003cstrong data-start=\"1199\" data-end=\"1222\"\u003eOperating Humidity:\u003c\/strong\u003e 10%–90% RH (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1253\" data-end=\"1318\"\u003e\n\u003cp data-start=\"1255\" data-end=\"1318\"\u003e\u003cstrong data-start=\"1255\" data-end=\"1279\"\u003eStorage Temperature:\u003c\/strong\u003e –40 °C to +75 °C (–40 °F to +167 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1319\" data-end=\"1371\"\u003e\n\u003cp data-start=\"1321\" data-end=\"1371\"\u003e\u003cstrong data-start=\"1321\" data-end=\"1342\"\u003eStorage Humidity:\u003c\/strong\u003e 5%–95% RH (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1373\" data-end=\"1376\"\u003e\n\u003ch2 data-start=\"1378\" data-end=\"1386\"\u003ePower\u003c\/h2\u003e\n\u003cul data-start=\"1387\" data-end=\"1516\"\u003e\n\u003cli data-start=\"1387\" data-end=\"1448\"\u003e\n\u003cp data-start=\"1389\" data-end=\"1448\"\u003e\u003cstrong data-start=\"1389\" data-end=\"1406\"\u003ePower Supply:\u003c\/strong\u003e External power adapter, 54 VDC \/ 2.22 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1449\" data-end=\"1516\"\u003e\n\u003cp data-start=\"1451\" data-end=\"1475\"\u003e\u003cstrong data-start=\"1451\" data-end=\"1473\"\u003ePower Consumption:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1478\" data-end=\"1516\"\u003e\n\u003cli data-start=\"1478\" data-end=\"1493\"\u003e\n\u003cp data-start=\"1480\" data-end=\"1493\"\u003eIdle: 5.7 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1496\" data-end=\"1516\"\u003e\n\u003cp data-start=\"1498\" data-end=\"1516\"\u003eFull Load: 115 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1518\" data-end=\"1521\"\u003e\n\u003ch2 data-start=\"1523\" data-end=\"1544\"\u003ePoE Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1545\" data-end=\"2096\"\u003e\n\u003cli data-start=\"1545\" data-end=\"1569\"\u003e\n\u003cp data-start=\"1547\" data-end=\"1569\"\u003e\u003cstrong data-start=\"1547\" data-end=\"1563\"\u003ePoE Support:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1570\" data-end=\"1644\"\u003e\n\u003cp data-start=\"1572\" data-end=\"1644\"\u003e\u003cstrong data-start=\"1572\" data-end=\"1590\"\u003ePoE Protocols:\u003c\/strong\u003e IEEE 802.3af \/ IEEE 802.3at \/ Hi-PoE \/ IEEE 802.3bt\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1645\" data-end=\"1772\"\u003e\n\u003cp data-start=\"1647\" data-end=\"1670\"\u003e\u003cstrong data-start=\"1647\" data-end=\"1668\"\u003ePoE Output Power:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1673\" data-end=\"1772\"\u003e\n\u003cli data-start=\"1673\" data-end=\"1703\"\u003e\n\u003cp data-start=\"1675\" data-end=\"1703\"\u003ePorts 1–2: ≤ 90 W per port\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1706\" data-end=\"1736\"\u003e\n\u003cp data-start=\"1708\" data-end=\"1736\"\u003ePorts 3–8: ≤ 30 W per port\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1739\" data-end=\"1772\"\u003e\n\u003cp data-start=\"1741\" data-end=\"1772\"\u003e\u003cstrong data-start=\"1741\" data-end=\"1762\"\u003eTotal PoE Budget:\u003c\/strong\u003e ≤ 110 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1773\" data-end=\"1915\"\u003e\n\u003cp data-start=\"1775\" data-end=\"1802\"\u003e\u003cstrong data-start=\"1775\" data-end=\"1800\"\u003ePoE Power Management:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1805\" data-end=\"1915\"\u003e\n\u003cli data-start=\"1805\" data-end=\"1841\"\u003e\n\u003cp data-start=\"1807\" data-end=\"1841\"\u003ePoE power consumption management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1844\" data-end=\"1864\"\u003e\n\u003cp data-start=\"1846\" data-end=\"1864\"\u003ePoE power on\/off\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1867\" data-end=\"1915\"\u003e\n\u003cp data-start=\"1869\" data-end=\"1915\"\u003eAutomatic PoE shutdown on overload detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1916\" data-end=\"2065\"\u003e\n\u003cp data-start=\"1918\" data-end=\"1943\"\u003e\u003cstrong data-start=\"1918\" data-end=\"1941\"\u003ePoE Pin Assignment:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1946\" data-end=\"2065\"\u003e\n\u003cli data-start=\"1946\" data-end=\"2010\"\u003e\n\u003cp data-start=\"1948\" data-end=\"1964\"\u003e\u003cstrong data-start=\"1948\" data-end=\"1962\"\u003ePorts 1–2:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1969\" data-end=\"2010\"\u003e\n\u003cli data-start=\"1969\" data-end=\"1987\"\u003e\n\u003cp data-start=\"1971\" data-end=\"1987\"\u003eV+: 1, 2, 4, 5\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1992\" data-end=\"2010\"\u003e\n\u003cp data-start=\"1994\" data-end=\"2010\"\u003eV–: 3, 6, 7, 8\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2013\" data-end=\"2065\"\u003e\n\u003cp data-start=\"2015\" data-end=\"2031\"\u003e\u003cstrong data-start=\"2015\" data-end=\"2029\"\u003ePorts 3–8:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2036\" data-end=\"2065\"\u003e\n\u003cli data-start=\"2036\" data-end=\"2048\"\u003e\n\u003cp data-start=\"2038\" data-end=\"2048\"\u003eV+: 1, 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2053\" data-end=\"2065\"\u003e\n\u003cp data-start=\"2055\" data-end=\"2065\"\u003eV–: 3, 6\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2066\" data-end=\"2096\"\u003e\n\u003cp data-start=\"2068\" data-end=\"2096\"\u003e\u003cstrong data-start=\"2068\" data-end=\"2090\"\u003eLong-Distance PoE:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2098\" data-end=\"2101\"\u003e\n\u003ch2 data-start=\"2103\" data-end=\"2123\"\u003eHardware Features\u003c\/h2\u003e\n\u003ch3 data-start=\"2124\" data-end=\"2148\"\u003eDIP Switch Functions\u003c\/h3\u003e\n\u003cul data-start=\"2149\" data-end=\"2563\"\u003e\n\u003cli data-start=\"2149\" data-end=\"2243\"\u003e\n\u003cp data-start=\"2151\" data-end=\"2170\"\u003e\u003cstrong data-start=\"2151\" data-end=\"2168\"\u003eManaged Mode:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2173\" data-end=\"2243\"\u003e\n\u003cli data-start=\"2173\" data-end=\"2219\"\u003e\n\u003cp data-start=\"2175\" data-end=\"2219\"\u003eON (default): Local web + cloud management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2222\" data-end=\"2243\"\u003e\n\u003cp data-start=\"2224\" data-end=\"2243\"\u003eOFF: Unmanaged mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2244\" data-end=\"2406\"\u003e\n\u003cp data-start=\"2246\" data-end=\"2265\"\u003e\u003cstrong data-start=\"2246\" data-end=\"2263\"\u003ePoE Watchdog:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2268\" data-end=\"2406\"\u003e\n\u003cli data-start=\"2268\" data-end=\"2290\"\u003e\n\u003cp data-start=\"2270\" data-end=\"2290\"\u003eMonitors ports 1–8\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2293\" data-end=\"2363\"\u003e\n\u003cp data-start=\"2295\" data-end=\"2363\"\u003eAutomatically restarts PoE if no traffic is detected for 2 minutes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2366\" data-end=\"2406\"\u003e\n\u003cp data-start=\"2368\" data-end=\"2406\"\u003e\u003cem data-start=\"2368\" data-end=\"2406\"\u003eOnly active when Managed Mode is OFF\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2407\" data-end=\"2538\"\u003e\n\u003cp data-start=\"2409\" data-end=\"2427\"\u003e\u003cstrong data-start=\"2409\" data-end=\"2425\"\u003eExtend Mode:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2430\" data-end=\"2538\"\u003e\n\u003cli data-start=\"2430\" data-end=\"2495\"\u003e\n\u003cp data-start=\"2432\" data-end=\"2495\"\u003ePorts 1–8 support up to \u003cstrong data-start=\"2456\" data-end=\"2465\"\u003e250 m\u003c\/strong\u003e transmission at \u003cstrong data-start=\"2482\" data-end=\"2493\"\u003e10 Mbps\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2498\" data-end=\"2538\"\u003e\n\u003cp data-start=\"2500\" data-end=\"2538\"\u003e\u003cem data-start=\"2500\" data-end=\"2538\"\u003eOnly active when Managed Mode is OFF\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2540\" data-end=\"2563\"\u003e\n\u003cp data-start=\"2542\" data-end=\"2563\"\u003e\u003cstrong data-start=\"2542\" data-end=\"2559\"\u003eReset Button:\u003c\/strong\u003e 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2565\" data-end=\"2568\"\u003e\n\u003ch2 data-start=\"2570\" data-end=\"2584\"\u003ePerformance\u003c\/h2\u003e\n\u003cul data-start=\"2585\" data-end=\"2736\"\u003e\n\u003cli data-start=\"2585\" data-end=\"2614\"\u003e\n\u003cp data-start=\"2587\" data-end=\"2614\"\u003e\u003cstrong data-start=\"2587\" data-end=\"2596\"\u003eMTBF:\u003c\/strong\u003e 2,482,955 hours\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2615\" data-end=\"2644\"\u003e\n\u003cp data-start=\"2617\" data-end=\"2644\"\u003e\u003cstrong data-start=\"2617\" data-end=\"2635\"\u003ePacket Buffer:\u003c\/strong\u003e 4 Mbit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2645\" data-end=\"2678\"\u003e\n\u003cp data-start=\"2647\" data-end=\"2678\"\u003e\u003cstrong data-start=\"2647\" data-end=\"2663\"\u003eJumbo Frame:\u003c\/strong\u003e 15,360 Bytes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2679\" data-end=\"2708\"\u003e\n\u003cp data-start=\"2681\" data-end=\"2708\"\u003e\u003cstrong data-start=\"2681\" data-end=\"2703\"\u003eMAC Address Table:\u003c\/strong\u003e 8K\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2709\" data-end=\"2736\"\u003e\n\u003cp data-start=\"2711\" data-end=\"2736\"\u003e\u003cstrong data-start=\"2711\" data-end=\"2731\"\u003eSupported VLANs:\u003c\/strong\u003e 32\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2738\" data-end=\"2741\"\u003e\n\u003ch2 data-start=\"2743\" data-end=\"2763\"\u003eNetwork Standards\u003c\/h2\u003e\n\u003cul data-start=\"2764\" data-end=\"2897\"\u003e\n\u003cli data-start=\"2764\" data-end=\"2897\"\u003e\n\u003cp data-start=\"2766\" data-end=\"2787\"\u003e\u003cstrong data-start=\"2766\" data-end=\"2785\"\u003eIEEE Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2790\" data-end=\"2897\"\u003e\n\u003cli data-start=\"2790\" data-end=\"2804\"\u003e\n\u003cp data-start=\"2792\" data-end=\"2804\"\u003eIEEE 802.3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2807\" data-end=\"2822\"\u003e\n\u003cp data-start=\"2809\" data-end=\"2822\"\u003eIEEE 802.3u\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2825\" data-end=\"2840\"\u003e\n\u003cp data-start=\"2827\" data-end=\"2840\"\u003eIEEE 802.3x\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2843\" data-end=\"2859\"\u003e\n\u003cp data-start=\"2845\" data-end=\"2859\"\u003eIEEE 802.3ab\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2862\" data-end=\"2878\"\u003e\n\u003cp data-start=\"2864\" data-end=\"2878\"\u003eIEEE 802.3az\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2881\" data-end=\"2897\"\u003e\n\u003cp data-start=\"2883\" data-end=\"2897\"\u003eIEEE 802.3ad\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2899\" data-end=\"2902\"\u003e\n\u003ch2 data-start=\"2904\" data-end=\"2923\"\u003eNetwork Features\u003c\/h2\u003e\n\u003cul data-start=\"2924\" data-end=\"3394\"\u003e\n\u003cli data-start=\"2924\" data-end=\"2967\"\u003e\n\u003cp data-start=\"2926\" data-end=\"2967\"\u003e\u003cstrong data-start=\"2926\" data-end=\"2955\"\u003eEthernet Loop Protection:\u003c\/strong\u003e STP, RSTP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2968\" data-end=\"2998\"\u003e\n\u003cp data-start=\"2970\" data-end=\"2998\"\u003e\u003cstrong data-start=\"2970\" data-end=\"2979\"\u003eVLAN:\u003c\/strong\u003e IEEE 802.1Q VLAN\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2999\" data-end=\"3043\"\u003e\n\u003cp data-start=\"3001\" data-end=\"3043\"\u003e\u003cstrong data-start=\"3001\" data-end=\"3022\"\u003eLink Aggregation:\u003c\/strong\u003e Static aggregation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3044\" data-end=\"3238\"\u003e\n\u003cp data-start=\"3046\" data-end=\"3066\"\u003e\u003cstrong data-start=\"3046\" data-end=\"3064\"\u003ePort Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3069\" data-end=\"3238\"\u003e\n\u003cli data-start=\"3069\" data-end=\"3097\"\u003e\n\u003cp data-start=\"3071\" data-end=\"3097\"\u003eIEEE 802.3x Flow Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3100\" data-end=\"3131\"\u003e\n\u003cp data-start=\"3102\" data-end=\"3131\"\u003eUnknown Unicast Suppression\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3134\" data-end=\"3161\"\u003e\n\u003cp data-start=\"3136\" data-end=\"3161\"\u003eMulticast Storm Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3164\" data-end=\"3191\"\u003e\n\u003cp data-start=\"3166\" data-end=\"3191\"\u003eBroadcast Storm Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3194\" data-end=\"3216\"\u003e\n\u003cp data-start=\"3196\" data-end=\"3216\"\u003eMAC + Port Binding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3219\" data-end=\"3238\"\u003e\n\u003cp data-start=\"3221\" data-end=\"3238\"\u003eLoop Prevention\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3239\" data-end=\"3309\"\u003e\n\u003cp data-start=\"3241\" data-end=\"3262\"\u003e\u003cstrong data-start=\"3241\" data-end=\"3260\"\u003ePort Mirroring:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3265\" data-end=\"3309\"\u003e\n\u003cli data-start=\"3265\" data-end=\"3289\"\u003e\n\u003cp data-start=\"3267\" data-end=\"3289\"\u003eLocal Port Mirroring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3292\" data-end=\"3309\"\u003e\n\u003cp data-start=\"3294\" data-end=\"3309\"\u003eN:1 Mirroring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3310\" data-end=\"3335\"\u003e\n\u003cp data-start=\"3312\" data-end=\"3335\"\u003e\u003cstrong data-start=\"3312\" data-end=\"3329\"\u003eLLDP Support:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3336\" data-end=\"3361\"\u003e\n\u003cp data-start=\"3338\" data-end=\"3361\"\u003e\u003cstrong data-start=\"3338\" data-end=\"3347\"\u003eDHCP:\u003c\/strong\u003e DHCP Client\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3362\" data-end=\"3394\"\u003e\n\u003cp data-start=\"3364\" data-end=\"3394\"\u003e\u003cstrong data-start=\"3364\" data-end=\"3377\"\u003eSecurity:\u003c\/strong\u003e Port Isolation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3396\" data-end=\"3399\"\u003e\n\u003ch2 data-start=\"3401\" data-end=\"3414\"\u003eManagement\u003c\/h2\u003e\n\u003cul data-start=\"3415\" data-end=\"3550\"\u003e\n\u003cli data-start=\"3415\" data-end=\"3486\"\u003e\n\u003cp data-start=\"3417\" data-end=\"3442\"\u003e\u003cstrong data-start=\"3417\" data-end=\"3440\"\u003eManagement Methods:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3445\" data-end=\"3486\"\u003e\n\u003cli data-start=\"3445\" data-end=\"3463\"\u003e\n\u003cp data-start=\"3447\" data-end=\"3463\"\u003eWeb Management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3466\" data-end=\"3486\"\u003e\n\u003cp data-start=\"3468\" data-end=\"3486\"\u003eCloud Management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3487\" data-end=\"3550\"\u003e\n\u003cp data-start=\"3489\" data-end=\"3520\"\u003e\u003cstrong data-start=\"3489\" data-end=\"3518\"\u003eMonitoring \u0026amp; Maintenance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3523\" data-end=\"3550\"\u003e\n\u003cli data-start=\"3523\" data-end=\"3531\"\u003e\n\u003cp data-start=\"3525\" data-end=\"3531\"\u003eLogs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3534\" data-end=\"3550\"\u003e\n\u003cp data-start=\"3536\" data-end=\"3550\"\u003eFault Alarms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3552\" data-end=\"3555\"\u003e\n\u003ch2 data-start=\"3557\" data-end=\"3570\"\u003eProtection\u003c\/h2\u003e\n\u003cul data-start=\"3571\" data-end=\"3734\"\u003e\n\u003cli data-start=\"3571\" data-end=\"3650\"\u003e\n\u003cp data-start=\"3573\" data-end=\"3594\"\u003e\u003cstrong data-start=\"3573\" data-end=\"3592\"\u003eESD Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3597\" data-end=\"3650\"\u003e\n\u003cli data-start=\"3597\" data-end=\"3620\"\u003e\n\u003cp data-start=\"3599\" data-end=\"3620\"\u003eAir Discharge: 8 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3623\" data-end=\"3650\"\u003e\n\u003cp data-start=\"3625\" data-end=\"3650\"\u003eContact Discharge: 6 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3651\" data-end=\"3734\"\u003e\n\u003cp data-start=\"3653\" data-end=\"3680\"\u003e\u003cstrong data-start=\"3653\" data-end=\"3678\"\u003eLightning Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3683\" data-end=\"3734\"\u003e\n\u003cli data-start=\"3683\" data-end=\"3704\"\u003e\n\u003cp data-start=\"3685\" data-end=\"3704\"\u003eCommon Mode: 6 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3707\" data-end=\"3734\"\u003e\n\u003cp data-start=\"3709\" data-end=\"3734\"\u003eDifferential Mode: 1 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3736\" data-end=\"3739\"\u003e\n\u003ch2 data-start=\"3741\" data-end=\"3767\"\u003ePhysical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"3768\" data-end=\"4041\"\u003e\n\u003cli data-start=\"3768\" data-end=\"3805\"\u003e\n\u003cp data-start=\"3770\" data-end=\"3805\"\u003e\u003cstrong data-start=\"3770\" data-end=\"3785\"\u003eNet Weight:\u003c\/strong\u003e 0.36 kg (0.79 lb)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3806\" data-end=\"3845\"\u003e\n\u003cp data-start=\"3808\" data-end=\"3845\"\u003e\u003cstrong data-start=\"3808\" data-end=\"3825\"\u003eGross Weight:\u003c\/strong\u003e 1.13 kg (2.49 lb)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3846\" data-end=\"3925\"\u003e\n\u003cp data-start=\"3848\" data-end=\"3873\"\u003e\u003cstrong data-start=\"3848\" data-end=\"3871\"\u003eProduct Dimensions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3876\" data-end=\"3925\"\u003e\n\u003cli data-start=\"3876\" data-end=\"3925\"\u003e\n\u003cp data-start=\"3878\" data-end=\"3925\"\u003e184.6 × 103.3 × 27 mm (7.27\" × 4.07\" × 1.06\")\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3926\" data-end=\"4004\"\u003e\n\u003cp data-start=\"3928\" data-end=\"3955\"\u003e\u003cstrong data-start=\"3928\" data-end=\"3953\"\u003ePackaging Dimensions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3958\" data-end=\"4004\"\u003e\n\u003cli data-start=\"3958\" data-end=\"4004\"\u003e\n\u003cp data-start=\"3960\" data-end=\"4004\"\u003e252 × 137 × 113 mm (9.92\" × 5.39\" × 4.45\")\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4005\" data-end=\"4041\"\u003e\n\u003cp data-start=\"4007\" data-end=\"4041\"\u003e\u003cstrong data-start=\"4007\" data-end=\"4027\"\u003eCasing Material:\u003c\/strong\u003e Sheet metal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4043\" data-end=\"4046\"\u003e\n\u003ch2 data-start=\"4048\" data-end=\"4063\"\u003eInstallation\u003c\/h2\u003e\n\u003cul data-start=\"4064\" data-end=\"4115\"\u003e\n\u003cli data-start=\"4064\" data-end=\"4115\"\u003e\n\u003cp data-start=\"4066\" data-end=\"4115\"\u003e\u003cstrong data-start=\"4066\" data-end=\"4087\"\u003eMounting Options:\u003c\/strong\u003e Desktop mount, Wall mount\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4117\" data-end=\"4120\"\u003e\n\u003ch2 data-start=\"4122\" data-end=\"4139\"\u003eCertifications\u003c\/h2\u003e\n\u003cul data-start=\"4140\" data-end=\"4148\"\u003e\n\u003cli data-start=\"4140\" data-end=\"4148\"\u003e\n\u003cp data-start=\"4142\" data-end=\"4148\"\u003e\u003cstrong data-start=\"4142\" data-end=\"4148\"\u003eCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4150\" data-end=\"4153\"\u003e\n\u003ch2 data-start=\"4155\" data-end=\"4170\"\u003ePacking List\u003c\/h2\u003e\n\u003cul data-start=\"4171\" data-end=\"4272\"\u003e\n\u003cli data-start=\"4171\" data-end=\"4190\"\u003e\n\u003cp data-start=\"4173\" data-end=\"4190\"\u003e1 × User Manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4191\" data-end=\"4231\"\u003e\n\u003cp data-start=\"4193\" data-end=\"4231\"\u003e1 × Legal and Regulatory Information\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4232\" data-end=\"4253\"\u003e\n\u003cp data-start=\"4234\" data-end=\"4253\"\u003e1 × Power Adapter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4254\" data-end=\"4272\"\u003e\n\u003cp data-start=\"4256\" data-end=\"4272\"\u003e1 × Power Cord\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 3 Year Dahua ANZ Manufacturer Warranty\u003c\/p\u003e","published_at":"2026-04-15T12:20:03+10:00","created_at":"2026-04-15T12:20:05+10:00","vendor":"Dahua","type":"Dahua PoE Switch","tags":["Australian Warranty","brand-Dahua","CCTV","Dahua","Dahua PoE Switch","DH-CS4010-8GT-110","Network Switch","PoE","PoE Switch","Security","Security Camera","Tekcart","type-Switch"],"price":23256,"price_min":23256,"price_max":23256,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":43221619703897,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"DH-CS4010-8GT-110","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Dahua CS4010-8GT-110 10-Port Cloud Managed Desktop Gigabit Switch with 8-Port POE","public_title":null,"options":["Default Title"],"price":23256,"weight":0,"compare_at_price":null,"inventory_management":"shopify","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/tekcart.com.au\/cdn\/shop\/files\/CS4010-8GT-110.png?v=1776219605"],"featured_image":"\/\/tekcart.com.au\/cdn\/shop\/files\/CS4010-8GT-110.png?v=1776219605","options":["Title"],"media":[{"alt":null,"id":28080822911065,"position":1,"preview_image":{"aspect_ratio":1.531,"height":1092,"width":1672,"src":"\/\/tekcart.com.au\/cdn\/shop\/files\/CS4010-8GT-110.png?v=1776219605"},"aspect_ratio":1.531,"height":1092,"media_type":"image","src":"\/\/tekcart.com.au\/cdn\/shop\/files\/CS4010-8GT-110.png?v=1776219605","width":1672}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch2 data-start=\"153\" data-end=\"220\"\u003e10-Port Cloud Managed Desktop \u003cstrong data-start=\"186\" data-end=\"197\"\u003eGigabit\u003c\/strong\u003e Switch with 8-Port PoE\u003c\/h2\u003e\n\u003ch3 data-start=\"222\" data-end=\"238\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"239\" data-end=\"804\"\u003e\n\u003cli data-start=\"239\" data-end=\"308\"\u003e\n\u003cp data-start=\"241\" data-end=\"308\"\u003e\u003cstrong data-start=\"241\" data-end=\"272\"\u003e8 × RJ-45 Gigabit PoE ports\u003c\/strong\u003e, \u003cstrong data-start=\"274\" data-end=\"308\"\u003e2 × RJ-45 Gigabit uplink ports\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"309\" data-end=\"432\"\u003e\n\u003cp data-start=\"311\" data-end=\"339\"\u003e\u003cstrong data-start=\"311\" data-end=\"337\"\u003e110 W total PoE budget\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"342\" data-end=\"432\"\u003e\n\u003cli data-start=\"342\" data-end=\"378\"\u003e\n\u003cp data-start=\"344\" data-end=\"378\"\u003eIEEE 802.3af\/at on all PoE ports\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"381\" data-end=\"432\"\u003e\n\u003cp data-start=\"383\" data-end=\"432\"\u003e\u003cstrong data-start=\"383\" data-end=\"432\"\u003eIEEE 802.3bt support on Ports 1–2 (red ports)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"433\" data-end=\"552\"\u003e\n\u003cp data-start=\"435\" data-end=\"474\"\u003e\u003cstrong data-start=\"435\" data-end=\"449\"\u003eDIP switch\u003c\/strong\u003e for fast mode switching:\u003c\/p\u003e\n\u003cul data-start=\"477\" data-end=\"552\"\u003e\n\u003cli data-start=\"477\" data-end=\"511\"\u003e\n\u003cp data-start=\"479\" data-end=\"511\"\u003eCloud-Managed \/ Unmanaged Mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"514\" data-end=\"530\"\u003e\n\u003cp data-start=\"516\" data-end=\"530\"\u003ePoE Watchdog\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"533\" data-end=\"552\"\u003e\n\u003cp data-start=\"535\" data-end=\"552\"\u003eLong-Distance PoE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"553\" data-end=\"603\"\u003e\n\u003cp data-start=\"555\" data-end=\"603\"\u003e\u003cstrong data-start=\"555\" data-end=\"586\"\u003eWide operating temperature:\u003c\/strong\u003e –10 °C to +55 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"604\" data-end=\"660\"\u003e\n\u003cp data-start=\"606\" data-end=\"660\"\u003eSupports \u003cstrong data-start=\"615\" data-end=\"634\"\u003eVLAN, STP, RSTP\u003c\/strong\u003e, and \u003cstrong data-start=\"640\" data-end=\"660\"\u003elink aggregation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"661\" data-end=\"734\"\u003e\n\u003cp data-start=\"663\" data-end=\"734\"\u003e\u003cstrong data-start=\"663\" data-end=\"678\"\u003eWeb-managed\u003c\/strong\u003e and \u003cstrong data-start=\"683\" data-end=\"715\"\u003ecentralised cloud management\u003c\/strong\u003e via \u003cstrong data-start=\"720\" data-end=\"734\"\u003eDoLynk App\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"735\" data-end=\"804\"\u003e\n\u003cp data-start=\"737\" data-end=\"804\"\u003eEasy configuration with \u003cstrong data-start=\"761\" data-end=\"804\"\u003eauto network detection and system setup\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"735\" data-end=\"804\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0047\/9510\/5391\/files\/DH-CS4010-8GT-110_V2_datasheet_20251104.pdf?v=1765923577\"\u003e\u003cstrong data-start=\"761\" data-end=\"804\"\u003eDatasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"806\" data-end=\"809\"\u003e\n\u003ch2 data-start=\"811\" data-end=\"834\"\u003eBasic Specifications\u003c\/h2\u003e\n\u003cul data-start=\"835\" data-end=\"946\"\u003e\n\u003cli data-start=\"835\" data-end=\"867\"\u003e\n\u003cp data-start=\"837\" data-end=\"867\"\u003e\u003cstrong data-start=\"837\" data-end=\"857\"\u003eSwitching Layer:\u003c\/strong\u003e Layer 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"868\" data-end=\"903\"\u003e\n\u003cp data-start=\"870\" data-end=\"903\"\u003e\u003cstrong data-start=\"870\" data-end=\"893\"\u003eSwitching Capacity:\u003c\/strong\u003e 20 Gbps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"904\" data-end=\"946\"\u003e\n\u003cp data-start=\"906\" data-end=\"946\"\u003e\u003cstrong data-start=\"906\" data-end=\"933\"\u003ePacket Forwarding Rate:\u003c\/strong\u003e 14.88 Mpps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"948\" data-end=\"951\"\u003e\n\u003ch2 data-start=\"953\" data-end=\"974\"\u003ePort Configuration\u003c\/h2\u003e\n\u003cul data-start=\"975\" data-end=\"1090\"\u003e\n\u003cli data-start=\"975\" data-end=\"1026\"\u003e\n\u003cp data-start=\"977\" data-end=\"1026\"\u003e\u003cstrong data-start=\"977\" data-end=\"991\"\u003ePorts 1–8:\u003c\/strong\u003e 8 × RJ-45 10\/100\/1000 Mbps (PoE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1027\" data-end=\"1090\"\u003e\n\u003cp data-start=\"1029\" data-end=\"1090\"\u003e\u003cstrong data-start=\"1029\" data-end=\"1044\"\u003ePorts 9–10:\u003c\/strong\u003e 2 × RJ-45 10\/100\/1000 Mbps (Gigabit uplink)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1092\" data-end=\"1095\"\u003e\n\u003ch2 data-start=\"1097\" data-end=\"1128\"\u003eEnvironmental Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1129\" data-end=\"1371\"\u003e\n\u003cli data-start=\"1129\" data-end=\"1196\"\u003e\n\u003cp data-start=\"1131\" data-end=\"1196\"\u003e\u003cstrong data-start=\"1131\" data-end=\"1157\"\u003eOperating Temperature:\u003c\/strong\u003e –10 °C to +55 °C (+14 °F to +131 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1197\" data-end=\"1252\"\u003e\n\u003cp data-start=\"1199\" data-end=\"1252\"\u003e\u003cstrong data-start=\"1199\" data-end=\"1222\"\u003eOperating Humidity:\u003c\/strong\u003e 10%–90% RH (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1253\" data-end=\"1318\"\u003e\n\u003cp data-start=\"1255\" data-end=\"1318\"\u003e\u003cstrong data-start=\"1255\" data-end=\"1279\"\u003eStorage Temperature:\u003c\/strong\u003e –40 °C to +75 °C (–40 °F to +167 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1319\" data-end=\"1371\"\u003e\n\u003cp data-start=\"1321\" data-end=\"1371\"\u003e\u003cstrong data-start=\"1321\" data-end=\"1342\"\u003eStorage Humidity:\u003c\/strong\u003e 5%–95% RH (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1373\" data-end=\"1376\"\u003e\n\u003ch2 data-start=\"1378\" data-end=\"1386\"\u003ePower\u003c\/h2\u003e\n\u003cul data-start=\"1387\" data-end=\"1516\"\u003e\n\u003cli data-start=\"1387\" data-end=\"1448\"\u003e\n\u003cp data-start=\"1389\" data-end=\"1448\"\u003e\u003cstrong data-start=\"1389\" data-end=\"1406\"\u003ePower Supply:\u003c\/strong\u003e External power adapter, 54 VDC \/ 2.22 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1449\" data-end=\"1516\"\u003e\n\u003cp data-start=\"1451\" data-end=\"1475\"\u003e\u003cstrong data-start=\"1451\" data-end=\"1473\"\u003ePower Consumption:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1478\" data-end=\"1516\"\u003e\n\u003cli data-start=\"1478\" data-end=\"1493\"\u003e\n\u003cp data-start=\"1480\" data-end=\"1493\"\u003eIdle: 5.7 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1496\" data-end=\"1516\"\u003e\n\u003cp data-start=\"1498\" data-end=\"1516\"\u003eFull Load: 115 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1518\" data-end=\"1521\"\u003e\n\u003ch2 data-start=\"1523\" data-end=\"1544\"\u003ePoE Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1545\" data-end=\"2096\"\u003e\n\u003cli data-start=\"1545\" data-end=\"1569\"\u003e\n\u003cp data-start=\"1547\" data-end=\"1569\"\u003e\u003cstrong data-start=\"1547\" data-end=\"1563\"\u003ePoE Support:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1570\" data-end=\"1644\"\u003e\n\u003cp data-start=\"1572\" data-end=\"1644\"\u003e\u003cstrong data-start=\"1572\" data-end=\"1590\"\u003ePoE Protocols:\u003c\/strong\u003e IEEE 802.3af \/ IEEE 802.3at \/ Hi-PoE \/ IEEE 802.3bt\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1645\" data-end=\"1772\"\u003e\n\u003cp data-start=\"1647\" data-end=\"1670\"\u003e\u003cstrong data-start=\"1647\" data-end=\"1668\"\u003ePoE Output Power:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1673\" data-end=\"1772\"\u003e\n\u003cli data-start=\"1673\" data-end=\"1703\"\u003e\n\u003cp data-start=\"1675\" data-end=\"1703\"\u003ePorts 1–2: ≤ 90 W per port\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1706\" data-end=\"1736\"\u003e\n\u003cp data-start=\"1708\" data-end=\"1736\"\u003ePorts 3–8: ≤ 30 W per port\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1739\" data-end=\"1772\"\u003e\n\u003cp data-start=\"1741\" data-end=\"1772\"\u003e\u003cstrong data-start=\"1741\" data-end=\"1762\"\u003eTotal PoE Budget:\u003c\/strong\u003e ≤ 110 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1773\" data-end=\"1915\"\u003e\n\u003cp data-start=\"1775\" data-end=\"1802\"\u003e\u003cstrong data-start=\"1775\" data-end=\"1800\"\u003ePoE Power Management:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1805\" data-end=\"1915\"\u003e\n\u003cli data-start=\"1805\" data-end=\"1841\"\u003e\n\u003cp data-start=\"1807\" data-end=\"1841\"\u003ePoE power consumption management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1844\" data-end=\"1864\"\u003e\n\u003cp data-start=\"1846\" data-end=\"1864\"\u003ePoE power on\/off\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1867\" data-end=\"1915\"\u003e\n\u003cp data-start=\"1869\" data-end=\"1915\"\u003eAutomatic PoE shutdown on overload detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1916\" data-end=\"2065\"\u003e\n\u003cp data-start=\"1918\" data-end=\"1943\"\u003e\u003cstrong data-start=\"1918\" data-end=\"1941\"\u003ePoE Pin Assignment:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1946\" data-end=\"2065\"\u003e\n\u003cli data-start=\"1946\" data-end=\"2010\"\u003e\n\u003cp data-start=\"1948\" data-end=\"1964\"\u003e\u003cstrong data-start=\"1948\" data-end=\"1962\"\u003ePorts 1–2:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1969\" data-end=\"2010\"\u003e\n\u003cli data-start=\"1969\" data-end=\"1987\"\u003e\n\u003cp data-start=\"1971\" data-end=\"1987\"\u003eV+: 1, 2, 4, 5\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1992\" data-end=\"2010\"\u003e\n\u003cp data-start=\"1994\" data-end=\"2010\"\u003eV–: 3, 6, 7, 8\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2013\" data-end=\"2065\"\u003e\n\u003cp data-start=\"2015\" data-end=\"2031\"\u003e\u003cstrong data-start=\"2015\" data-end=\"2029\"\u003ePorts 3–8:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2036\" data-end=\"2065\"\u003e\n\u003cli data-start=\"2036\" data-end=\"2048\"\u003e\n\u003cp data-start=\"2038\" data-end=\"2048\"\u003eV+: 1, 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2053\" data-end=\"2065\"\u003e\n\u003cp data-start=\"2055\" data-end=\"2065\"\u003eV–: 3, 6\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2066\" data-end=\"2096\"\u003e\n\u003cp data-start=\"2068\" data-end=\"2096\"\u003e\u003cstrong data-start=\"2068\" data-end=\"2090\"\u003eLong-Distance PoE:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2098\" data-end=\"2101\"\u003e\n\u003ch2 data-start=\"2103\" data-end=\"2123\"\u003eHardware Features\u003c\/h2\u003e\n\u003ch3 data-start=\"2124\" data-end=\"2148\"\u003eDIP Switch Functions\u003c\/h3\u003e\n\u003cul data-start=\"2149\" data-end=\"2563\"\u003e\n\u003cli data-start=\"2149\" data-end=\"2243\"\u003e\n\u003cp data-start=\"2151\" data-end=\"2170\"\u003e\u003cstrong data-start=\"2151\" data-end=\"2168\"\u003eManaged Mode:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2173\" data-end=\"2243\"\u003e\n\u003cli data-start=\"2173\" data-end=\"2219\"\u003e\n\u003cp data-start=\"2175\" data-end=\"2219\"\u003eON (default): Local web + cloud management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2222\" data-end=\"2243\"\u003e\n\u003cp data-start=\"2224\" data-end=\"2243\"\u003eOFF: Unmanaged mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2244\" data-end=\"2406\"\u003e\n\u003cp data-start=\"2246\" data-end=\"2265\"\u003e\u003cstrong data-start=\"2246\" data-end=\"2263\"\u003ePoE Watchdog:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2268\" data-end=\"2406\"\u003e\n\u003cli data-start=\"2268\" data-end=\"2290\"\u003e\n\u003cp data-start=\"2270\" data-end=\"2290\"\u003eMonitors ports 1–8\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2293\" data-end=\"2363\"\u003e\n\u003cp data-start=\"2295\" data-end=\"2363\"\u003eAutomatically restarts PoE if no traffic is detected for 2 minutes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2366\" data-end=\"2406\"\u003e\n\u003cp data-start=\"2368\" data-end=\"2406\"\u003e\u003cem data-start=\"2368\" data-end=\"2406\"\u003eOnly active when Managed Mode is OFF\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2407\" data-end=\"2538\"\u003e\n\u003cp data-start=\"2409\" data-end=\"2427\"\u003e\u003cstrong data-start=\"2409\" data-end=\"2425\"\u003eExtend Mode:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2430\" data-end=\"2538\"\u003e\n\u003cli data-start=\"2430\" data-end=\"2495\"\u003e\n\u003cp data-start=\"2432\" data-end=\"2495\"\u003ePorts 1–8 support up to \u003cstrong data-start=\"2456\" data-end=\"2465\"\u003e250 m\u003c\/strong\u003e transmission at \u003cstrong data-start=\"2482\" data-end=\"2493\"\u003e10 Mbps\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2498\" data-end=\"2538\"\u003e\n\u003cp data-start=\"2500\" data-end=\"2538\"\u003e\u003cem data-start=\"2500\" data-end=\"2538\"\u003eOnly active when Managed Mode is OFF\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2540\" data-end=\"2563\"\u003e\n\u003cp data-start=\"2542\" data-end=\"2563\"\u003e\u003cstrong data-start=\"2542\" data-end=\"2559\"\u003eReset Button:\u003c\/strong\u003e 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2565\" data-end=\"2568\"\u003e\n\u003ch2 data-start=\"2570\" data-end=\"2584\"\u003ePerformance\u003c\/h2\u003e\n\u003cul data-start=\"2585\" data-end=\"2736\"\u003e\n\u003cli data-start=\"2585\" data-end=\"2614\"\u003e\n\u003cp data-start=\"2587\" data-end=\"2614\"\u003e\u003cstrong data-start=\"2587\" data-end=\"2596\"\u003eMTBF:\u003c\/strong\u003e 2,482,955 hours\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2615\" data-end=\"2644\"\u003e\n\u003cp data-start=\"2617\" data-end=\"2644\"\u003e\u003cstrong data-start=\"2617\" data-end=\"2635\"\u003ePacket Buffer:\u003c\/strong\u003e 4 Mbit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2645\" data-end=\"2678\"\u003e\n\u003cp data-start=\"2647\" data-end=\"2678\"\u003e\u003cstrong data-start=\"2647\" data-end=\"2663\"\u003eJumbo Frame:\u003c\/strong\u003e 15,360 Bytes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2679\" data-end=\"2708\"\u003e\n\u003cp data-start=\"2681\" data-end=\"2708\"\u003e\u003cstrong data-start=\"2681\" data-end=\"2703\"\u003eMAC Address Table:\u003c\/strong\u003e 8K\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2709\" data-end=\"2736\"\u003e\n\u003cp data-start=\"2711\" data-end=\"2736\"\u003e\u003cstrong data-start=\"2711\" data-end=\"2731\"\u003eSupported VLANs:\u003c\/strong\u003e 32\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2738\" data-end=\"2741\"\u003e\n\u003ch2 data-start=\"2743\" data-end=\"2763\"\u003eNetwork Standards\u003c\/h2\u003e\n\u003cul data-start=\"2764\" data-end=\"2897\"\u003e\n\u003cli data-start=\"2764\" data-end=\"2897\"\u003e\n\u003cp data-start=\"2766\" data-end=\"2787\"\u003e\u003cstrong data-start=\"2766\" data-end=\"2785\"\u003eIEEE Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2790\" data-end=\"2897\"\u003e\n\u003cli data-start=\"2790\" data-end=\"2804\"\u003e\n\u003cp data-start=\"2792\" data-end=\"2804\"\u003eIEEE 802.3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2807\" data-end=\"2822\"\u003e\n\u003cp data-start=\"2809\" data-end=\"2822\"\u003eIEEE 802.3u\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2825\" data-end=\"2840\"\u003e\n\u003cp data-start=\"2827\" data-end=\"2840\"\u003eIEEE 802.3x\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2843\" data-end=\"2859\"\u003e\n\u003cp data-start=\"2845\" data-end=\"2859\"\u003eIEEE 802.3ab\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2862\" data-end=\"2878\"\u003e\n\u003cp data-start=\"2864\" data-end=\"2878\"\u003eIEEE 802.3az\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2881\" data-end=\"2897\"\u003e\n\u003cp data-start=\"2883\" data-end=\"2897\"\u003eIEEE 802.3ad\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2899\" data-end=\"2902\"\u003e\n\u003ch2 data-start=\"2904\" data-end=\"2923\"\u003eNetwork Features\u003c\/h2\u003e\n\u003cul data-start=\"2924\" data-end=\"3394\"\u003e\n\u003cli data-start=\"2924\" data-end=\"2967\"\u003e\n\u003cp data-start=\"2926\" data-end=\"2967\"\u003e\u003cstrong data-start=\"2926\" data-end=\"2955\"\u003eEthernet Loop Protection:\u003c\/strong\u003e STP, RSTP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2968\" data-end=\"2998\"\u003e\n\u003cp data-start=\"2970\" data-end=\"2998\"\u003e\u003cstrong data-start=\"2970\" data-end=\"2979\"\u003eVLAN:\u003c\/strong\u003e IEEE 802.1Q VLAN\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2999\" data-end=\"3043\"\u003e\n\u003cp data-start=\"3001\" data-end=\"3043\"\u003e\u003cstrong data-start=\"3001\" data-end=\"3022\"\u003eLink Aggregation:\u003c\/strong\u003e Static aggregation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3044\" data-end=\"3238\"\u003e\n\u003cp data-start=\"3046\" data-end=\"3066\"\u003e\u003cstrong data-start=\"3046\" data-end=\"3064\"\u003ePort Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3069\" data-end=\"3238\"\u003e\n\u003cli data-start=\"3069\" data-end=\"3097\"\u003e\n\u003cp data-start=\"3071\" data-end=\"3097\"\u003eIEEE 802.3x Flow Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3100\" data-end=\"3131\"\u003e\n\u003cp data-start=\"3102\" data-end=\"3131\"\u003eUnknown Unicast Suppression\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3134\" data-end=\"3161\"\u003e\n\u003cp data-start=\"3136\" data-end=\"3161\"\u003eMulticast Storm Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3164\" data-end=\"3191\"\u003e\n\u003cp data-start=\"3166\" data-end=\"3191\"\u003eBroadcast Storm Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3194\" data-end=\"3216\"\u003e\n\u003cp data-start=\"3196\" data-end=\"3216\"\u003eMAC + Port Binding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3219\" data-end=\"3238\"\u003e\n\u003cp data-start=\"3221\" data-end=\"3238\"\u003eLoop Prevention\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3239\" data-end=\"3309\"\u003e\n\u003cp data-start=\"3241\" data-end=\"3262\"\u003e\u003cstrong data-start=\"3241\" data-end=\"3260\"\u003ePort Mirroring:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3265\" data-end=\"3309\"\u003e\n\u003cli data-start=\"3265\" data-end=\"3289\"\u003e\n\u003cp data-start=\"3267\" data-end=\"3289\"\u003eLocal Port Mirroring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3292\" data-end=\"3309\"\u003e\n\u003cp data-start=\"3294\" data-end=\"3309\"\u003eN:1 Mirroring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3310\" data-end=\"3335\"\u003e\n\u003cp data-start=\"3312\" data-end=\"3335\"\u003e\u003cstrong data-start=\"3312\" data-end=\"3329\"\u003eLLDP Support:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3336\" data-end=\"3361\"\u003e\n\u003cp data-start=\"3338\" data-end=\"3361\"\u003e\u003cstrong data-start=\"3338\" data-end=\"3347\"\u003eDHCP:\u003c\/strong\u003e DHCP Client\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3362\" data-end=\"3394\"\u003e\n\u003cp data-start=\"3364\" data-end=\"3394\"\u003e\u003cstrong data-start=\"3364\" data-end=\"3377\"\u003eSecurity:\u003c\/strong\u003e Port Isolation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3396\" data-end=\"3399\"\u003e\n\u003ch2 data-start=\"3401\" data-end=\"3414\"\u003eManagement\u003c\/h2\u003e\n\u003cul data-start=\"3415\" data-end=\"3550\"\u003e\n\u003cli data-start=\"3415\" data-end=\"3486\"\u003e\n\u003cp data-start=\"3417\" data-end=\"3442\"\u003e\u003cstrong data-start=\"3417\" data-end=\"3440\"\u003eManagement Methods:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3445\" data-end=\"3486\"\u003e\n\u003cli data-start=\"3445\" data-end=\"3463\"\u003e\n\u003cp data-start=\"3447\" data-end=\"3463\"\u003eWeb Management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3466\" data-end=\"3486\"\u003e\n\u003cp data-start=\"3468\" data-end=\"3486\"\u003eCloud Management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3487\" data-end=\"3550\"\u003e\n\u003cp data-start=\"3489\" data-end=\"3520\"\u003e\u003cstrong data-start=\"3489\" data-end=\"3518\"\u003eMonitoring \u0026amp; Maintenance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3523\" data-end=\"3550\"\u003e\n\u003cli data-start=\"3523\" data-end=\"3531\"\u003e\n\u003cp data-start=\"3525\" data-end=\"3531\"\u003eLogs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3534\" data-end=\"3550\"\u003e\n\u003cp data-start=\"3536\" data-end=\"3550\"\u003eFault Alarms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3552\" data-end=\"3555\"\u003e\n\u003ch2 data-start=\"3557\" data-end=\"3570\"\u003eProtection\u003c\/h2\u003e\n\u003cul data-start=\"3571\" data-end=\"3734\"\u003e\n\u003cli data-start=\"3571\" data-end=\"3650\"\u003e\n\u003cp data-start=\"3573\" data-end=\"3594\"\u003e\u003cstrong data-start=\"3573\" data-end=\"3592\"\u003eESD Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3597\" data-end=\"3650\"\u003e\n\u003cli data-start=\"3597\" data-end=\"3620\"\u003e\n\u003cp data-start=\"3599\" data-end=\"3620\"\u003eAir Discharge: 8 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3623\" data-end=\"3650\"\u003e\n\u003cp data-start=\"3625\" data-end=\"3650\"\u003eContact Discharge: 6 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3651\" data-end=\"3734\"\u003e\n\u003cp data-start=\"3653\" data-end=\"3680\"\u003e\u003cstrong data-start=\"3653\" data-end=\"3678\"\u003eLightning Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3683\" data-end=\"3734\"\u003e\n\u003cli data-start=\"3683\" data-end=\"3704\"\u003e\n\u003cp data-start=\"3685\" data-end=\"3704\"\u003eCommon Mode: 6 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3707\" data-end=\"3734\"\u003e\n\u003cp data-start=\"3709\" data-end=\"3734\"\u003eDifferential Mode: 1 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3736\" data-end=\"3739\"\u003e\n\u003ch2 data-start=\"3741\" data-end=\"3767\"\u003ePhysical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"3768\" data-end=\"4041\"\u003e\n\u003cli data-start=\"3768\" data-end=\"3805\"\u003e\n\u003cp data-start=\"3770\" data-end=\"3805\"\u003e\u003cstrong data-start=\"3770\" data-end=\"3785\"\u003eNet Weight:\u003c\/strong\u003e 0.36 kg (0.79 lb)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3806\" data-end=\"3845\"\u003e\n\u003cp data-start=\"3808\" data-end=\"3845\"\u003e\u003cstrong data-start=\"3808\" data-end=\"3825\"\u003eGross Weight:\u003c\/strong\u003e 1.13 kg (2.49 lb)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3846\" data-end=\"3925\"\u003e\n\u003cp data-start=\"3848\" data-end=\"3873\"\u003e\u003cstrong data-start=\"3848\" data-end=\"3871\"\u003eProduct Dimensions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3876\" data-end=\"3925\"\u003e\n\u003cli data-start=\"3876\" data-end=\"3925\"\u003e\n\u003cp data-start=\"3878\" data-end=\"3925\"\u003e184.6 × 103.3 × 27 mm (7.27\" × 4.07\" × 1.06\")\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3926\" data-end=\"4004\"\u003e\n\u003cp data-start=\"3928\" data-end=\"3955\"\u003e\u003cstrong data-start=\"3928\" data-end=\"3953\"\u003ePackaging Dimensions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3958\" data-end=\"4004\"\u003e\n\u003cli data-start=\"3958\" data-end=\"4004\"\u003e\n\u003cp data-start=\"3960\" data-end=\"4004\"\u003e252 × 137 × 113 mm (9.92\" × 5.39\" × 4.45\")\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4005\" data-end=\"4041\"\u003e\n\u003cp data-start=\"4007\" data-end=\"4041\"\u003e\u003cstrong data-start=\"4007\" data-end=\"4027\"\u003eCasing Material:\u003c\/strong\u003e Sheet metal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4043\" data-end=\"4046\"\u003e\n\u003ch2 data-start=\"4048\" data-end=\"4063\"\u003eInstallation\u003c\/h2\u003e\n\u003cul data-start=\"4064\" data-end=\"4115\"\u003e\n\u003cli data-start=\"4064\" data-end=\"4115\"\u003e\n\u003cp data-start=\"4066\" data-end=\"4115\"\u003e\u003cstrong data-start=\"4066\" data-end=\"4087\"\u003eMounting Options:\u003c\/strong\u003e Desktop mount, Wall mount\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4117\" data-end=\"4120\"\u003e\n\u003ch2 data-start=\"4122\" data-end=\"4139\"\u003eCertifications\u003c\/h2\u003e\n\u003cul data-start=\"4140\" data-end=\"4148\"\u003e\n\u003cli data-start=\"4140\" data-end=\"4148\"\u003e\n\u003cp data-start=\"4142\" data-end=\"4148\"\u003e\u003cstrong data-start=\"4142\" data-end=\"4148\"\u003eCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4150\" data-end=\"4153\"\u003e\n\u003ch2 data-start=\"4155\" data-end=\"4170\"\u003ePacking List\u003c\/h2\u003e\n\u003cul data-start=\"4171\" data-end=\"4272\"\u003e\n\u003cli data-start=\"4171\" data-end=\"4190\"\u003e\n\u003cp data-start=\"4173\" data-end=\"4190\"\u003e1 × User Manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4191\" data-end=\"4231\"\u003e\n\u003cp data-start=\"4193\" data-end=\"4231\"\u003e1 × Legal and Regulatory Information\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4232\" data-end=\"4253\"\u003e\n\u003cp data-start=\"4234\" data-end=\"4253\"\u003e1 × Power Adapter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4254\" data-end=\"4272\"\u003e\n\u003cp data-start=\"4256\" data-end=\"4272\"\u003e1 × Power Cord\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 3 Year Dahua ANZ Manufacturer Warranty\u003c\/p\u003e"}
Translation missing: en.products.product.regular_price $782.89 -
-
{"id":8191822069849,"title":"Dahua CS4010-8GT-110 10-Port Cloud Managed Desktop Gigabit Switch with 8-Port POE","handle":"cs4010-8gt-110-dahua-10-port-cloud-managed-desktop-gigabit-switch-with-8-port-poe","description":"\u003ch2 data-start=\"153\" data-end=\"220\"\u003e10-Port Cloud Managed Desktop \u003cstrong data-start=\"186\" data-end=\"197\"\u003eGigabit\u003c\/strong\u003e Switch with 8-Port PoE\u003c\/h2\u003e\n\u003ch3 data-start=\"222\" data-end=\"238\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"239\" data-end=\"804\"\u003e\n\u003cli data-start=\"239\" data-end=\"308\"\u003e\n\u003cp data-start=\"241\" data-end=\"308\"\u003e\u003cstrong data-start=\"241\" data-end=\"272\"\u003e8 × RJ-45 Gigabit PoE ports\u003c\/strong\u003e, \u003cstrong data-start=\"274\" data-end=\"308\"\u003e2 × RJ-45 Gigabit uplink ports\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"309\" data-end=\"432\"\u003e\n\u003cp data-start=\"311\" data-end=\"339\"\u003e\u003cstrong data-start=\"311\" data-end=\"337\"\u003e110 W total PoE budget\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"342\" data-end=\"432\"\u003e\n\u003cli data-start=\"342\" data-end=\"378\"\u003e\n\u003cp data-start=\"344\" data-end=\"378\"\u003eIEEE 802.3af\/at on all PoE ports\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"381\" data-end=\"432\"\u003e\n\u003cp data-start=\"383\" data-end=\"432\"\u003e\u003cstrong data-start=\"383\" data-end=\"432\"\u003eIEEE 802.3bt support on Ports 1–2 (red ports)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"433\" data-end=\"552\"\u003e\n\u003cp data-start=\"435\" data-end=\"474\"\u003e\u003cstrong data-start=\"435\" data-end=\"449\"\u003eDIP switch\u003c\/strong\u003e for fast mode switching:\u003c\/p\u003e\n\u003cul data-start=\"477\" data-end=\"552\"\u003e\n\u003cli data-start=\"477\" data-end=\"511\"\u003e\n\u003cp data-start=\"479\" data-end=\"511\"\u003eCloud-Managed \/ Unmanaged Mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"514\" data-end=\"530\"\u003e\n\u003cp data-start=\"516\" data-end=\"530\"\u003ePoE Watchdog\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"533\" data-end=\"552\"\u003e\n\u003cp data-start=\"535\" data-end=\"552\"\u003eLong-Distance PoE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"553\" data-end=\"603\"\u003e\n\u003cp data-start=\"555\" data-end=\"603\"\u003e\u003cstrong data-start=\"555\" data-end=\"586\"\u003eWide operating temperature:\u003c\/strong\u003e –10 °C to +55 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"604\" data-end=\"660\"\u003e\n\u003cp data-start=\"606\" data-end=\"660\"\u003eSupports \u003cstrong data-start=\"615\" data-end=\"634\"\u003eVLAN, STP, RSTP\u003c\/strong\u003e, and \u003cstrong data-start=\"640\" data-end=\"660\"\u003elink aggregation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"661\" data-end=\"734\"\u003e\n\u003cp data-start=\"663\" data-end=\"734\"\u003e\u003cstrong data-start=\"663\" data-end=\"678\"\u003eWeb-managed\u003c\/strong\u003e and \u003cstrong data-start=\"683\" data-end=\"715\"\u003ecentralised cloud management\u003c\/strong\u003e via \u003cstrong data-start=\"720\" data-end=\"734\"\u003eDoLynk App\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"735\" data-end=\"804\"\u003e\n\u003cp data-start=\"737\" data-end=\"804\"\u003eEasy configuration with \u003cstrong data-start=\"761\" data-end=\"804\"\u003eauto network detection and system setup\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"735\" data-end=\"804\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0047\/9510\/5391\/files\/DH-CS4010-8GT-110_V2_datasheet_20251104.pdf?v=1765923577\"\u003e\u003cstrong data-start=\"761\" data-end=\"804\"\u003eDatasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"806\" data-end=\"809\"\u003e\n\u003ch2 data-start=\"811\" data-end=\"834\"\u003eBasic Specifications\u003c\/h2\u003e\n\u003cul data-start=\"835\" data-end=\"946\"\u003e\n\u003cli data-start=\"835\" data-end=\"867\"\u003e\n\u003cp data-start=\"837\" data-end=\"867\"\u003e\u003cstrong data-start=\"837\" data-end=\"857\"\u003eSwitching Layer:\u003c\/strong\u003e Layer 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"868\" data-end=\"903\"\u003e\n\u003cp data-start=\"870\" data-end=\"903\"\u003e\u003cstrong data-start=\"870\" data-end=\"893\"\u003eSwitching Capacity:\u003c\/strong\u003e 20 Gbps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"904\" data-end=\"946\"\u003e\n\u003cp data-start=\"906\" data-end=\"946\"\u003e\u003cstrong data-start=\"906\" data-end=\"933\"\u003ePacket Forwarding Rate:\u003c\/strong\u003e 14.88 Mpps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"948\" data-end=\"951\"\u003e\n\u003ch2 data-start=\"953\" data-end=\"974\"\u003ePort Configuration\u003c\/h2\u003e\n\u003cul data-start=\"975\" data-end=\"1090\"\u003e\n\u003cli data-start=\"975\" data-end=\"1026\"\u003e\n\u003cp data-start=\"977\" data-end=\"1026\"\u003e\u003cstrong data-start=\"977\" data-end=\"991\"\u003ePorts 1–8:\u003c\/strong\u003e 8 × RJ-45 10\/100\/1000 Mbps (PoE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1027\" data-end=\"1090\"\u003e\n\u003cp data-start=\"1029\" data-end=\"1090\"\u003e\u003cstrong data-start=\"1029\" data-end=\"1044\"\u003ePorts 9–10:\u003c\/strong\u003e 2 × RJ-45 10\/100\/1000 Mbps (Gigabit uplink)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1092\" data-end=\"1095\"\u003e\n\u003ch2 data-start=\"1097\" data-end=\"1128\"\u003eEnvironmental Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1129\" data-end=\"1371\"\u003e\n\u003cli data-start=\"1129\" data-end=\"1196\"\u003e\n\u003cp data-start=\"1131\" data-end=\"1196\"\u003e\u003cstrong data-start=\"1131\" data-end=\"1157\"\u003eOperating Temperature:\u003c\/strong\u003e –10 °C to +55 °C (+14 °F to +131 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1197\" data-end=\"1252\"\u003e\n\u003cp data-start=\"1199\" data-end=\"1252\"\u003e\u003cstrong data-start=\"1199\" data-end=\"1222\"\u003eOperating Humidity:\u003c\/strong\u003e 10%–90% RH (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1253\" data-end=\"1318\"\u003e\n\u003cp data-start=\"1255\" data-end=\"1318\"\u003e\u003cstrong data-start=\"1255\" data-end=\"1279\"\u003eStorage Temperature:\u003c\/strong\u003e –40 °C to +75 °C (–40 °F to +167 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1319\" data-end=\"1371\"\u003e\n\u003cp data-start=\"1321\" data-end=\"1371\"\u003e\u003cstrong data-start=\"1321\" data-end=\"1342\"\u003eStorage Humidity:\u003c\/strong\u003e 5%–95% RH (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1373\" data-end=\"1376\"\u003e\n\u003ch2 data-start=\"1378\" data-end=\"1386\"\u003ePower\u003c\/h2\u003e\n\u003cul data-start=\"1387\" data-end=\"1516\"\u003e\n\u003cli data-start=\"1387\" data-end=\"1448\"\u003e\n\u003cp data-start=\"1389\" data-end=\"1448\"\u003e\u003cstrong data-start=\"1389\" data-end=\"1406\"\u003ePower Supply:\u003c\/strong\u003e External power adapter, 54 VDC \/ 2.22 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1449\" data-end=\"1516\"\u003e\n\u003cp data-start=\"1451\" data-end=\"1475\"\u003e\u003cstrong data-start=\"1451\" data-end=\"1473\"\u003ePower Consumption:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1478\" data-end=\"1516\"\u003e\n\u003cli data-start=\"1478\" data-end=\"1493\"\u003e\n\u003cp data-start=\"1480\" data-end=\"1493\"\u003eIdle: 5.7 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1496\" data-end=\"1516\"\u003e\n\u003cp data-start=\"1498\" data-end=\"1516\"\u003eFull Load: 115 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1518\" data-end=\"1521\"\u003e\n\u003ch2 data-start=\"1523\" data-end=\"1544\"\u003ePoE Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1545\" data-end=\"2096\"\u003e\n\u003cli data-start=\"1545\" data-end=\"1569\"\u003e\n\u003cp data-start=\"1547\" data-end=\"1569\"\u003e\u003cstrong data-start=\"1547\" data-end=\"1563\"\u003ePoE Support:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1570\" data-end=\"1644\"\u003e\n\u003cp data-start=\"1572\" data-end=\"1644\"\u003e\u003cstrong data-start=\"1572\" data-end=\"1590\"\u003ePoE Protocols:\u003c\/strong\u003e IEEE 802.3af \/ IEEE 802.3at \/ Hi-PoE \/ IEEE 802.3bt\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1645\" data-end=\"1772\"\u003e\n\u003cp data-start=\"1647\" data-end=\"1670\"\u003e\u003cstrong data-start=\"1647\" data-end=\"1668\"\u003ePoE Output Power:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1673\" data-end=\"1772\"\u003e\n\u003cli data-start=\"1673\" data-end=\"1703\"\u003e\n\u003cp data-start=\"1675\" data-end=\"1703\"\u003ePorts 1–2: ≤ 90 W per port\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1706\" data-end=\"1736\"\u003e\n\u003cp data-start=\"1708\" data-end=\"1736\"\u003ePorts 3–8: ≤ 30 W per port\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1739\" data-end=\"1772\"\u003e\n\u003cp data-start=\"1741\" data-end=\"1772\"\u003e\u003cstrong data-start=\"1741\" data-end=\"1762\"\u003eTotal PoE Budget:\u003c\/strong\u003e ≤ 110 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1773\" data-end=\"1915\"\u003e\n\u003cp data-start=\"1775\" data-end=\"1802\"\u003e\u003cstrong data-start=\"1775\" data-end=\"1800\"\u003ePoE Power Management:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1805\" data-end=\"1915\"\u003e\n\u003cli data-start=\"1805\" data-end=\"1841\"\u003e\n\u003cp data-start=\"1807\" data-end=\"1841\"\u003ePoE power consumption management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1844\" data-end=\"1864\"\u003e\n\u003cp data-start=\"1846\" data-end=\"1864\"\u003ePoE power on\/off\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1867\" data-end=\"1915\"\u003e\n\u003cp data-start=\"1869\" data-end=\"1915\"\u003eAutomatic PoE shutdown on overload detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1916\" data-end=\"2065\"\u003e\n\u003cp data-start=\"1918\" data-end=\"1943\"\u003e\u003cstrong data-start=\"1918\" data-end=\"1941\"\u003ePoE Pin Assignment:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1946\" data-end=\"2065\"\u003e\n\u003cli data-start=\"1946\" data-end=\"2010\"\u003e\n\u003cp data-start=\"1948\" data-end=\"1964\"\u003e\u003cstrong data-start=\"1948\" data-end=\"1962\"\u003ePorts 1–2:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1969\" data-end=\"2010\"\u003e\n\u003cli data-start=\"1969\" data-end=\"1987\"\u003e\n\u003cp data-start=\"1971\" data-end=\"1987\"\u003eV+: 1, 2, 4, 5\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1992\" data-end=\"2010\"\u003e\n\u003cp data-start=\"1994\" data-end=\"2010\"\u003eV–: 3, 6, 7, 8\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2013\" data-end=\"2065\"\u003e\n\u003cp data-start=\"2015\" data-end=\"2031\"\u003e\u003cstrong data-start=\"2015\" data-end=\"2029\"\u003ePorts 3–8:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2036\" data-end=\"2065\"\u003e\n\u003cli data-start=\"2036\" data-end=\"2048\"\u003e\n\u003cp data-start=\"2038\" data-end=\"2048\"\u003eV+: 1, 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2053\" data-end=\"2065\"\u003e\n\u003cp data-start=\"2055\" data-end=\"2065\"\u003eV–: 3, 6\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2066\" data-end=\"2096\"\u003e\n\u003cp data-start=\"2068\" data-end=\"2096\"\u003e\u003cstrong data-start=\"2068\" data-end=\"2090\"\u003eLong-Distance PoE:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2098\" data-end=\"2101\"\u003e\n\u003ch2 data-start=\"2103\" data-end=\"2123\"\u003eHardware Features\u003c\/h2\u003e\n\u003ch3 data-start=\"2124\" data-end=\"2148\"\u003eDIP Switch Functions\u003c\/h3\u003e\n\u003cul data-start=\"2149\" data-end=\"2563\"\u003e\n\u003cli data-start=\"2149\" data-end=\"2243\"\u003e\n\u003cp data-start=\"2151\" data-end=\"2170\"\u003e\u003cstrong data-start=\"2151\" data-end=\"2168\"\u003eManaged Mode:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2173\" data-end=\"2243\"\u003e\n\u003cli data-start=\"2173\" data-end=\"2219\"\u003e\n\u003cp data-start=\"2175\" data-end=\"2219\"\u003eON (default): Local web + cloud management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2222\" data-end=\"2243\"\u003e\n\u003cp data-start=\"2224\" data-end=\"2243\"\u003eOFF: Unmanaged mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2244\" data-end=\"2406\"\u003e\n\u003cp data-start=\"2246\" data-end=\"2265\"\u003e\u003cstrong data-start=\"2246\" data-end=\"2263\"\u003ePoE Watchdog:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2268\" data-end=\"2406\"\u003e\n\u003cli data-start=\"2268\" data-end=\"2290\"\u003e\n\u003cp data-start=\"2270\" data-end=\"2290\"\u003eMonitors ports 1–8\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2293\" data-end=\"2363\"\u003e\n\u003cp data-start=\"2295\" data-end=\"2363\"\u003eAutomatically restarts PoE if no traffic is detected for 2 minutes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2366\" data-end=\"2406\"\u003e\n\u003cp data-start=\"2368\" data-end=\"2406\"\u003e\u003cem data-start=\"2368\" data-end=\"2406\"\u003eOnly active when Managed Mode is OFF\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2407\" data-end=\"2538\"\u003e\n\u003cp data-start=\"2409\" data-end=\"2427\"\u003e\u003cstrong data-start=\"2409\" data-end=\"2425\"\u003eExtend Mode:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2430\" data-end=\"2538\"\u003e\n\u003cli data-start=\"2430\" data-end=\"2495\"\u003e\n\u003cp data-start=\"2432\" data-end=\"2495\"\u003ePorts 1–8 support up to \u003cstrong data-start=\"2456\" data-end=\"2465\"\u003e250 m\u003c\/strong\u003e transmission at \u003cstrong data-start=\"2482\" data-end=\"2493\"\u003e10 Mbps\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2498\" data-end=\"2538\"\u003e\n\u003cp data-start=\"2500\" data-end=\"2538\"\u003e\u003cem data-start=\"2500\" data-end=\"2538\"\u003eOnly active when Managed Mode is OFF\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2540\" data-end=\"2563\"\u003e\n\u003cp data-start=\"2542\" data-end=\"2563\"\u003e\u003cstrong data-start=\"2542\" data-end=\"2559\"\u003eReset Button:\u003c\/strong\u003e 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2565\" data-end=\"2568\"\u003e\n\u003ch2 data-start=\"2570\" data-end=\"2584\"\u003ePerformance\u003c\/h2\u003e\n\u003cul data-start=\"2585\" data-end=\"2736\"\u003e\n\u003cli data-start=\"2585\" data-end=\"2614\"\u003e\n\u003cp data-start=\"2587\" data-end=\"2614\"\u003e\u003cstrong data-start=\"2587\" data-end=\"2596\"\u003eMTBF:\u003c\/strong\u003e 2,482,955 hours\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2615\" data-end=\"2644\"\u003e\n\u003cp data-start=\"2617\" data-end=\"2644\"\u003e\u003cstrong data-start=\"2617\" data-end=\"2635\"\u003ePacket Buffer:\u003c\/strong\u003e 4 Mbit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2645\" data-end=\"2678\"\u003e\n\u003cp data-start=\"2647\" data-end=\"2678\"\u003e\u003cstrong data-start=\"2647\" data-end=\"2663\"\u003eJumbo Frame:\u003c\/strong\u003e 15,360 Bytes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2679\" data-end=\"2708\"\u003e\n\u003cp data-start=\"2681\" data-end=\"2708\"\u003e\u003cstrong data-start=\"2681\" data-end=\"2703\"\u003eMAC Address Table:\u003c\/strong\u003e 8K\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2709\" data-end=\"2736\"\u003e\n\u003cp data-start=\"2711\" data-end=\"2736\"\u003e\u003cstrong data-start=\"2711\" data-end=\"2731\"\u003eSupported VLANs:\u003c\/strong\u003e 32\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2738\" data-end=\"2741\"\u003e\n\u003ch2 data-start=\"2743\" data-end=\"2763\"\u003eNetwork Standards\u003c\/h2\u003e\n\u003cul data-start=\"2764\" data-end=\"2897\"\u003e\n\u003cli data-start=\"2764\" data-end=\"2897\"\u003e\n\u003cp data-start=\"2766\" data-end=\"2787\"\u003e\u003cstrong data-start=\"2766\" data-end=\"2785\"\u003eIEEE Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2790\" data-end=\"2897\"\u003e\n\u003cli data-start=\"2790\" data-end=\"2804\"\u003e\n\u003cp data-start=\"2792\" data-end=\"2804\"\u003eIEEE 802.3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2807\" data-end=\"2822\"\u003e\n\u003cp data-start=\"2809\" data-end=\"2822\"\u003eIEEE 802.3u\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2825\" data-end=\"2840\"\u003e\n\u003cp data-start=\"2827\" data-end=\"2840\"\u003eIEEE 802.3x\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2843\" data-end=\"2859\"\u003e\n\u003cp data-start=\"2845\" data-end=\"2859\"\u003eIEEE 802.3ab\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2862\" data-end=\"2878\"\u003e\n\u003cp data-start=\"2864\" data-end=\"2878\"\u003eIEEE 802.3az\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2881\" data-end=\"2897\"\u003e\n\u003cp data-start=\"2883\" data-end=\"2897\"\u003eIEEE 802.3ad\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2899\" data-end=\"2902\"\u003e\n\u003ch2 data-start=\"2904\" data-end=\"2923\"\u003eNetwork Features\u003c\/h2\u003e\n\u003cul data-start=\"2924\" data-end=\"3394\"\u003e\n\u003cli data-start=\"2924\" data-end=\"2967\"\u003e\n\u003cp data-start=\"2926\" data-end=\"2967\"\u003e\u003cstrong data-start=\"2926\" data-end=\"2955\"\u003eEthernet Loop Protection:\u003c\/strong\u003e STP, RSTP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2968\" data-end=\"2998\"\u003e\n\u003cp data-start=\"2970\" data-end=\"2998\"\u003e\u003cstrong data-start=\"2970\" data-end=\"2979\"\u003eVLAN:\u003c\/strong\u003e IEEE 802.1Q VLAN\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2999\" data-end=\"3043\"\u003e\n\u003cp data-start=\"3001\" data-end=\"3043\"\u003e\u003cstrong data-start=\"3001\" data-end=\"3022\"\u003eLink Aggregation:\u003c\/strong\u003e Static aggregation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3044\" data-end=\"3238\"\u003e\n\u003cp data-start=\"3046\" data-end=\"3066\"\u003e\u003cstrong data-start=\"3046\" data-end=\"3064\"\u003ePort Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3069\" data-end=\"3238\"\u003e\n\u003cli data-start=\"3069\" data-end=\"3097\"\u003e\n\u003cp data-start=\"3071\" data-end=\"3097\"\u003eIEEE 802.3x Flow Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3100\" data-end=\"3131\"\u003e\n\u003cp data-start=\"3102\" data-end=\"3131\"\u003eUnknown Unicast Suppression\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3134\" data-end=\"3161\"\u003e\n\u003cp data-start=\"3136\" data-end=\"3161\"\u003eMulticast Storm Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3164\" data-end=\"3191\"\u003e\n\u003cp data-start=\"3166\" data-end=\"3191\"\u003eBroadcast Storm Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3194\" data-end=\"3216\"\u003e\n\u003cp data-start=\"3196\" data-end=\"3216\"\u003eMAC + Port Binding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3219\" data-end=\"3238\"\u003e\n\u003cp data-start=\"3221\" data-end=\"3238\"\u003eLoop Prevention\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3239\" data-end=\"3309\"\u003e\n\u003cp data-start=\"3241\" data-end=\"3262\"\u003e\u003cstrong data-start=\"3241\" data-end=\"3260\"\u003ePort Mirroring:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3265\" data-end=\"3309\"\u003e\n\u003cli data-start=\"3265\" data-end=\"3289\"\u003e\n\u003cp data-start=\"3267\" data-end=\"3289\"\u003eLocal Port Mirroring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3292\" data-end=\"3309\"\u003e\n\u003cp data-start=\"3294\" data-end=\"3309\"\u003eN:1 Mirroring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3310\" data-end=\"3335\"\u003e\n\u003cp data-start=\"3312\" data-end=\"3335\"\u003e\u003cstrong data-start=\"3312\" data-end=\"3329\"\u003eLLDP Support:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3336\" data-end=\"3361\"\u003e\n\u003cp data-start=\"3338\" data-end=\"3361\"\u003e\u003cstrong data-start=\"3338\" data-end=\"3347\"\u003eDHCP:\u003c\/strong\u003e DHCP Client\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3362\" data-end=\"3394\"\u003e\n\u003cp data-start=\"3364\" data-end=\"3394\"\u003e\u003cstrong data-start=\"3364\" data-end=\"3377\"\u003eSecurity:\u003c\/strong\u003e Port Isolation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3396\" data-end=\"3399\"\u003e\n\u003ch2 data-start=\"3401\" data-end=\"3414\"\u003eManagement\u003c\/h2\u003e\n\u003cul data-start=\"3415\" data-end=\"3550\"\u003e\n\u003cli data-start=\"3415\" data-end=\"3486\"\u003e\n\u003cp data-start=\"3417\" data-end=\"3442\"\u003e\u003cstrong data-start=\"3417\" data-end=\"3440\"\u003eManagement Methods:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3445\" data-end=\"3486\"\u003e\n\u003cli data-start=\"3445\" data-end=\"3463\"\u003e\n\u003cp data-start=\"3447\" data-end=\"3463\"\u003eWeb Management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3466\" data-end=\"3486\"\u003e\n\u003cp data-start=\"3468\" data-end=\"3486\"\u003eCloud Management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3487\" data-end=\"3550\"\u003e\n\u003cp data-start=\"3489\" data-end=\"3520\"\u003e\u003cstrong data-start=\"3489\" data-end=\"3518\"\u003eMonitoring \u0026amp; Maintenance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3523\" data-end=\"3550\"\u003e\n\u003cli data-start=\"3523\" data-end=\"3531\"\u003e\n\u003cp data-start=\"3525\" data-end=\"3531\"\u003eLogs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3534\" data-end=\"3550\"\u003e\n\u003cp data-start=\"3536\" data-end=\"3550\"\u003eFault Alarms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3552\" data-end=\"3555\"\u003e\n\u003ch2 data-start=\"3557\" data-end=\"3570\"\u003eProtection\u003c\/h2\u003e\n\u003cul data-start=\"3571\" data-end=\"3734\"\u003e\n\u003cli data-start=\"3571\" data-end=\"3650\"\u003e\n\u003cp data-start=\"3573\" data-end=\"3594\"\u003e\u003cstrong data-start=\"3573\" data-end=\"3592\"\u003eESD Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3597\" data-end=\"3650\"\u003e\n\u003cli data-start=\"3597\" data-end=\"3620\"\u003e\n\u003cp data-start=\"3599\" data-end=\"3620\"\u003eAir Discharge: 8 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3623\" data-end=\"3650\"\u003e\n\u003cp data-start=\"3625\" data-end=\"3650\"\u003eContact Discharge: 6 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3651\" data-end=\"3734\"\u003e\n\u003cp data-start=\"3653\" data-end=\"3680\"\u003e\u003cstrong data-start=\"3653\" data-end=\"3678\"\u003eLightning Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3683\" data-end=\"3734\"\u003e\n\u003cli data-start=\"3683\" data-end=\"3704\"\u003e\n\u003cp data-start=\"3685\" data-end=\"3704\"\u003eCommon Mode: 6 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3707\" data-end=\"3734\"\u003e\n\u003cp data-start=\"3709\" data-end=\"3734\"\u003eDifferential Mode: 1 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3736\" data-end=\"3739\"\u003e\n\u003ch2 data-start=\"3741\" data-end=\"3767\"\u003ePhysical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"3768\" data-end=\"4041\"\u003e\n\u003cli data-start=\"3768\" data-end=\"3805\"\u003e\n\u003cp data-start=\"3770\" data-end=\"3805\"\u003e\u003cstrong data-start=\"3770\" data-end=\"3785\"\u003eNet Weight:\u003c\/strong\u003e 0.36 kg (0.79 lb)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3806\" data-end=\"3845\"\u003e\n\u003cp data-start=\"3808\" data-end=\"3845\"\u003e\u003cstrong data-start=\"3808\" data-end=\"3825\"\u003eGross Weight:\u003c\/strong\u003e 1.13 kg (2.49 lb)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3846\" data-end=\"3925\"\u003e\n\u003cp data-start=\"3848\" data-end=\"3873\"\u003e\u003cstrong data-start=\"3848\" data-end=\"3871\"\u003eProduct Dimensions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3876\" data-end=\"3925\"\u003e\n\u003cli data-start=\"3876\" data-end=\"3925\"\u003e\n\u003cp data-start=\"3878\" data-end=\"3925\"\u003e184.6 × 103.3 × 27 mm (7.27\" × 4.07\" × 1.06\")\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3926\" data-end=\"4004\"\u003e\n\u003cp data-start=\"3928\" data-end=\"3955\"\u003e\u003cstrong data-start=\"3928\" data-end=\"3953\"\u003ePackaging Dimensions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3958\" data-end=\"4004\"\u003e\n\u003cli data-start=\"3958\" data-end=\"4004\"\u003e\n\u003cp data-start=\"3960\" data-end=\"4004\"\u003e252 × 137 × 113 mm (9.92\" × 5.39\" × 4.45\")\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4005\" data-end=\"4041\"\u003e\n\u003cp data-start=\"4007\" data-end=\"4041\"\u003e\u003cstrong data-start=\"4007\" data-end=\"4027\"\u003eCasing Material:\u003c\/strong\u003e Sheet metal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4043\" data-end=\"4046\"\u003e\n\u003ch2 data-start=\"4048\" data-end=\"4063\"\u003eInstallation\u003c\/h2\u003e\n\u003cul data-start=\"4064\" data-end=\"4115\"\u003e\n\u003cli data-start=\"4064\" data-end=\"4115\"\u003e\n\u003cp data-start=\"4066\" data-end=\"4115\"\u003e\u003cstrong data-start=\"4066\" data-end=\"4087\"\u003eMounting Options:\u003c\/strong\u003e Desktop mount, Wall mount\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4117\" data-end=\"4120\"\u003e\n\u003ch2 data-start=\"4122\" data-end=\"4139\"\u003eCertifications\u003c\/h2\u003e\n\u003cul data-start=\"4140\" data-end=\"4148\"\u003e\n\u003cli data-start=\"4140\" data-end=\"4148\"\u003e\n\u003cp data-start=\"4142\" data-end=\"4148\"\u003e\u003cstrong data-start=\"4142\" data-end=\"4148\"\u003eCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4150\" data-end=\"4153\"\u003e\n\u003ch2 data-start=\"4155\" data-end=\"4170\"\u003ePacking List\u003c\/h2\u003e\n\u003cul data-start=\"4171\" data-end=\"4272\"\u003e\n\u003cli data-start=\"4171\" data-end=\"4190\"\u003e\n\u003cp data-start=\"4173\" data-end=\"4190\"\u003e1 × User Manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4191\" data-end=\"4231\"\u003e\n\u003cp data-start=\"4193\" data-end=\"4231\"\u003e1 × Legal and Regulatory Information\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4232\" data-end=\"4253\"\u003e\n\u003cp data-start=\"4234\" data-end=\"4253\"\u003e1 × Power Adapter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4254\" data-end=\"4272\"\u003e\n\u003cp data-start=\"4256\" data-end=\"4272\"\u003e1 × Power Cord\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 3 Year Dahua ANZ Manufacturer Warranty\u003c\/p\u003e","published_at":"2026-04-15T12:20:03+10:00","created_at":"2026-04-15T12:20:05+10:00","vendor":"Dahua","type":"Dahua PoE Switch","tags":["Australian Warranty","brand-Dahua","CCTV","Dahua","Dahua PoE Switch","DH-CS4010-8GT-110","Network Switch","PoE","PoE Switch","Security","Security Camera","Tekcart","type-Switch"],"price":23256,"price_min":23256,"price_max":23256,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":43221619703897,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"DH-CS4010-8GT-110","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Dahua CS4010-8GT-110 10-Port Cloud Managed Desktop Gigabit Switch with 8-Port POE","public_title":null,"options":["Default Title"],"price":23256,"weight":0,"compare_at_price":null,"inventory_management":"shopify","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/tekcart.com.au\/cdn\/shop\/files\/CS4010-8GT-110.png?v=1776219605"],"featured_image":"\/\/tekcart.com.au\/cdn\/shop\/files\/CS4010-8GT-110.png?v=1776219605","options":["Title"],"media":[{"alt":null,"id":28080822911065,"position":1,"preview_image":{"aspect_ratio":1.531,"height":1092,"width":1672,"src":"\/\/tekcart.com.au\/cdn\/shop\/files\/CS4010-8GT-110.png?v=1776219605"},"aspect_ratio":1.531,"height":1092,"media_type":"image","src":"\/\/tekcart.com.au\/cdn\/shop\/files\/CS4010-8GT-110.png?v=1776219605","width":1672}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch2 data-start=\"153\" data-end=\"220\"\u003e10-Port Cloud Managed Desktop \u003cstrong data-start=\"186\" data-end=\"197\"\u003eGigabit\u003c\/strong\u003e Switch with 8-Port PoE\u003c\/h2\u003e\n\u003ch3 data-start=\"222\" data-end=\"238\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"239\" data-end=\"804\"\u003e\n\u003cli data-start=\"239\" data-end=\"308\"\u003e\n\u003cp data-start=\"241\" data-end=\"308\"\u003e\u003cstrong data-start=\"241\" data-end=\"272\"\u003e8 × RJ-45 Gigabit PoE ports\u003c\/strong\u003e, \u003cstrong data-start=\"274\" data-end=\"308\"\u003e2 × RJ-45 Gigabit uplink ports\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"309\" data-end=\"432\"\u003e\n\u003cp data-start=\"311\" data-end=\"339\"\u003e\u003cstrong data-start=\"311\" data-end=\"337\"\u003e110 W total PoE budget\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"342\" data-end=\"432\"\u003e\n\u003cli data-start=\"342\" data-end=\"378\"\u003e\n\u003cp data-start=\"344\" data-end=\"378\"\u003eIEEE 802.3af\/at on all PoE ports\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"381\" data-end=\"432\"\u003e\n\u003cp data-start=\"383\" data-end=\"432\"\u003e\u003cstrong data-start=\"383\" data-end=\"432\"\u003eIEEE 802.3bt support on Ports 1–2 (red ports)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"433\" data-end=\"552\"\u003e\n\u003cp data-start=\"435\" data-end=\"474\"\u003e\u003cstrong data-start=\"435\" data-end=\"449\"\u003eDIP switch\u003c\/strong\u003e for fast mode switching:\u003c\/p\u003e\n\u003cul data-start=\"477\" data-end=\"552\"\u003e\n\u003cli data-start=\"477\" data-end=\"511\"\u003e\n\u003cp data-start=\"479\" data-end=\"511\"\u003eCloud-Managed \/ Unmanaged Mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"514\" data-end=\"530\"\u003e\n\u003cp data-start=\"516\" data-end=\"530\"\u003ePoE Watchdog\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"533\" data-end=\"552\"\u003e\n\u003cp data-start=\"535\" data-end=\"552\"\u003eLong-Distance PoE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"553\" data-end=\"603\"\u003e\n\u003cp data-start=\"555\" data-end=\"603\"\u003e\u003cstrong data-start=\"555\" data-end=\"586\"\u003eWide operating temperature:\u003c\/strong\u003e –10 °C to +55 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"604\" data-end=\"660\"\u003e\n\u003cp data-start=\"606\" data-end=\"660\"\u003eSupports \u003cstrong data-start=\"615\" data-end=\"634\"\u003eVLAN, STP, RSTP\u003c\/strong\u003e, and \u003cstrong data-start=\"640\" data-end=\"660\"\u003elink aggregation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"661\" data-end=\"734\"\u003e\n\u003cp data-start=\"663\" data-end=\"734\"\u003e\u003cstrong data-start=\"663\" data-end=\"678\"\u003eWeb-managed\u003c\/strong\u003e and \u003cstrong data-start=\"683\" data-end=\"715\"\u003ecentralised cloud management\u003c\/strong\u003e via \u003cstrong data-start=\"720\" data-end=\"734\"\u003eDoLynk App\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"735\" data-end=\"804\"\u003e\n\u003cp data-start=\"737\" data-end=\"804\"\u003eEasy configuration with \u003cstrong data-start=\"761\" data-end=\"804\"\u003eauto network detection and system setup\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"735\" data-end=\"804\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0047\/9510\/5391\/files\/DH-CS4010-8GT-110_V2_datasheet_20251104.pdf?v=1765923577\"\u003e\u003cstrong data-start=\"761\" data-end=\"804\"\u003eDatasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"806\" data-end=\"809\"\u003e\n\u003ch2 data-start=\"811\" data-end=\"834\"\u003eBasic Specifications\u003c\/h2\u003e\n\u003cul data-start=\"835\" data-end=\"946\"\u003e\n\u003cli data-start=\"835\" data-end=\"867\"\u003e\n\u003cp data-start=\"837\" data-end=\"867\"\u003e\u003cstrong data-start=\"837\" data-end=\"857\"\u003eSwitching Layer:\u003c\/strong\u003e Layer 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"868\" data-end=\"903\"\u003e\n\u003cp data-start=\"870\" data-end=\"903\"\u003e\u003cstrong data-start=\"870\" data-end=\"893\"\u003eSwitching Capacity:\u003c\/strong\u003e 20 Gbps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"904\" data-end=\"946\"\u003e\n\u003cp data-start=\"906\" data-end=\"946\"\u003e\u003cstrong data-start=\"906\" data-end=\"933\"\u003ePacket Forwarding Rate:\u003c\/strong\u003e 14.88 Mpps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"948\" data-end=\"951\"\u003e\n\u003ch2 data-start=\"953\" data-end=\"974\"\u003ePort Configuration\u003c\/h2\u003e\n\u003cul data-start=\"975\" data-end=\"1090\"\u003e\n\u003cli data-start=\"975\" data-end=\"1026\"\u003e\n\u003cp data-start=\"977\" data-end=\"1026\"\u003e\u003cstrong data-start=\"977\" data-end=\"991\"\u003ePorts 1–8:\u003c\/strong\u003e 8 × RJ-45 10\/100\/1000 Mbps (PoE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1027\" data-end=\"1090\"\u003e\n\u003cp data-start=\"1029\" data-end=\"1090\"\u003e\u003cstrong data-start=\"1029\" data-end=\"1044\"\u003ePorts 9–10:\u003c\/strong\u003e 2 × RJ-45 10\/100\/1000 Mbps (Gigabit uplink)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1092\" data-end=\"1095\"\u003e\n\u003ch2 data-start=\"1097\" data-end=\"1128\"\u003eEnvironmental Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1129\" data-end=\"1371\"\u003e\n\u003cli data-start=\"1129\" data-end=\"1196\"\u003e\n\u003cp data-start=\"1131\" data-end=\"1196\"\u003e\u003cstrong data-start=\"1131\" data-end=\"1157\"\u003eOperating Temperature:\u003c\/strong\u003e –10 °C to +55 °C (+14 °F to +131 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1197\" data-end=\"1252\"\u003e\n\u003cp data-start=\"1199\" data-end=\"1252\"\u003e\u003cstrong data-start=\"1199\" data-end=\"1222\"\u003eOperating Humidity:\u003c\/strong\u003e 10%–90% RH (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1253\" data-end=\"1318\"\u003e\n\u003cp data-start=\"1255\" data-end=\"1318\"\u003e\u003cstrong data-start=\"1255\" data-end=\"1279\"\u003eStorage Temperature:\u003c\/strong\u003e –40 °C to +75 °C (–40 °F to +167 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1319\" data-end=\"1371\"\u003e\n\u003cp data-start=\"1321\" data-end=\"1371\"\u003e\u003cstrong data-start=\"1321\" data-end=\"1342\"\u003eStorage Humidity:\u003c\/strong\u003e 5%–95% RH (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1373\" data-end=\"1376\"\u003e\n\u003ch2 data-start=\"1378\" data-end=\"1386\"\u003ePower\u003c\/h2\u003e\n\u003cul data-start=\"1387\" data-end=\"1516\"\u003e\n\u003cli data-start=\"1387\" data-end=\"1448\"\u003e\n\u003cp data-start=\"1389\" data-end=\"1448\"\u003e\u003cstrong data-start=\"1389\" data-end=\"1406\"\u003ePower Supply:\u003c\/strong\u003e External power adapter, 54 VDC \/ 2.22 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1449\" data-end=\"1516\"\u003e\n\u003cp data-start=\"1451\" data-end=\"1475\"\u003e\u003cstrong data-start=\"1451\" data-end=\"1473\"\u003ePower Consumption:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1478\" data-end=\"1516\"\u003e\n\u003cli data-start=\"1478\" data-end=\"1493\"\u003e\n\u003cp data-start=\"1480\" data-end=\"1493\"\u003eIdle: 5.7 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1496\" data-end=\"1516\"\u003e\n\u003cp data-start=\"1498\" data-end=\"1516\"\u003eFull Load: 115 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1518\" data-end=\"1521\"\u003e\n\u003ch2 data-start=\"1523\" data-end=\"1544\"\u003ePoE Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1545\" data-end=\"2096\"\u003e\n\u003cli data-start=\"1545\" data-end=\"1569\"\u003e\n\u003cp data-start=\"1547\" data-end=\"1569\"\u003e\u003cstrong data-start=\"1547\" data-end=\"1563\"\u003ePoE Support:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1570\" data-end=\"1644\"\u003e\n\u003cp data-start=\"1572\" data-end=\"1644\"\u003e\u003cstrong data-start=\"1572\" data-end=\"1590\"\u003ePoE Protocols:\u003c\/strong\u003e IEEE 802.3af \/ IEEE 802.3at \/ Hi-PoE \/ IEEE 802.3bt\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1645\" data-end=\"1772\"\u003e\n\u003cp data-start=\"1647\" data-end=\"1670\"\u003e\u003cstrong data-start=\"1647\" data-end=\"1668\"\u003ePoE Output Power:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1673\" data-end=\"1772\"\u003e\n\u003cli data-start=\"1673\" data-end=\"1703\"\u003e\n\u003cp data-start=\"1675\" data-end=\"1703\"\u003ePorts 1–2: ≤ 90 W per port\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1706\" data-end=\"1736\"\u003e\n\u003cp data-start=\"1708\" data-end=\"1736\"\u003ePorts 3–8: ≤ 30 W per port\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1739\" data-end=\"1772\"\u003e\n\u003cp data-start=\"1741\" data-end=\"1772\"\u003e\u003cstrong data-start=\"1741\" data-end=\"1762\"\u003eTotal PoE Budget:\u003c\/strong\u003e ≤ 110 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1773\" data-end=\"1915\"\u003e\n\u003cp data-start=\"1775\" data-end=\"1802\"\u003e\u003cstrong data-start=\"1775\" data-end=\"1800\"\u003ePoE Power Management:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1805\" data-end=\"1915\"\u003e\n\u003cli data-start=\"1805\" data-end=\"1841\"\u003e\n\u003cp data-start=\"1807\" data-end=\"1841\"\u003ePoE power consumption management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1844\" data-end=\"1864\"\u003e\n\u003cp data-start=\"1846\" data-end=\"1864\"\u003ePoE power on\/off\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1867\" data-end=\"1915\"\u003e\n\u003cp data-start=\"1869\" data-end=\"1915\"\u003eAutomatic PoE shutdown on overload detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1916\" data-end=\"2065\"\u003e\n\u003cp data-start=\"1918\" data-end=\"1943\"\u003e\u003cstrong data-start=\"1918\" data-end=\"1941\"\u003ePoE Pin Assignment:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1946\" data-end=\"2065\"\u003e\n\u003cli data-start=\"1946\" data-end=\"2010\"\u003e\n\u003cp data-start=\"1948\" data-end=\"1964\"\u003e\u003cstrong data-start=\"1948\" data-end=\"1962\"\u003ePorts 1–2:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1969\" data-end=\"2010\"\u003e\n\u003cli data-start=\"1969\" data-end=\"1987\"\u003e\n\u003cp data-start=\"1971\" data-end=\"1987\"\u003eV+: 1, 2, 4, 5\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1992\" data-end=\"2010\"\u003e\n\u003cp data-start=\"1994\" data-end=\"2010\"\u003eV–: 3, 6, 7, 8\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2013\" data-end=\"2065\"\u003e\n\u003cp data-start=\"2015\" data-end=\"2031\"\u003e\u003cstrong data-start=\"2015\" data-end=\"2029\"\u003ePorts 3–8:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2036\" data-end=\"2065\"\u003e\n\u003cli data-start=\"2036\" data-end=\"2048\"\u003e\n\u003cp data-start=\"2038\" data-end=\"2048\"\u003eV+: 1, 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2053\" data-end=\"2065\"\u003e\n\u003cp data-start=\"2055\" data-end=\"2065\"\u003eV–: 3, 6\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2066\" data-end=\"2096\"\u003e\n\u003cp data-start=\"2068\" data-end=\"2096\"\u003e\u003cstrong data-start=\"2068\" data-end=\"2090\"\u003eLong-Distance PoE:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2098\" data-end=\"2101\"\u003e\n\u003ch2 data-start=\"2103\" data-end=\"2123\"\u003eHardware Features\u003c\/h2\u003e\n\u003ch3 data-start=\"2124\" data-end=\"2148\"\u003eDIP Switch Functions\u003c\/h3\u003e\n\u003cul data-start=\"2149\" data-end=\"2563\"\u003e\n\u003cli data-start=\"2149\" data-end=\"2243\"\u003e\n\u003cp data-start=\"2151\" data-end=\"2170\"\u003e\u003cstrong data-start=\"2151\" data-end=\"2168\"\u003eManaged Mode:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2173\" data-end=\"2243\"\u003e\n\u003cli data-start=\"2173\" data-end=\"2219\"\u003e\n\u003cp data-start=\"2175\" data-end=\"2219\"\u003eON (default): Local web + cloud management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2222\" data-end=\"2243\"\u003e\n\u003cp data-start=\"2224\" data-end=\"2243\"\u003eOFF: Unmanaged mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2244\" data-end=\"2406\"\u003e\n\u003cp data-start=\"2246\" data-end=\"2265\"\u003e\u003cstrong data-start=\"2246\" data-end=\"2263\"\u003ePoE Watchdog:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2268\" data-end=\"2406\"\u003e\n\u003cli data-start=\"2268\" data-end=\"2290\"\u003e\n\u003cp data-start=\"2270\" data-end=\"2290\"\u003eMonitors ports 1–8\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2293\" data-end=\"2363\"\u003e\n\u003cp data-start=\"2295\" data-end=\"2363\"\u003eAutomatically restarts PoE if no traffic is detected for 2 minutes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2366\" data-end=\"2406\"\u003e\n\u003cp data-start=\"2368\" data-end=\"2406\"\u003e\u003cem data-start=\"2368\" data-end=\"2406\"\u003eOnly active when Managed Mode is OFF\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2407\" data-end=\"2538\"\u003e\n\u003cp data-start=\"2409\" data-end=\"2427\"\u003e\u003cstrong data-start=\"2409\" data-end=\"2425\"\u003eExtend Mode:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2430\" data-end=\"2538\"\u003e\n\u003cli data-start=\"2430\" data-end=\"2495\"\u003e\n\u003cp data-start=\"2432\" data-end=\"2495\"\u003ePorts 1–8 support up to \u003cstrong data-start=\"2456\" data-end=\"2465\"\u003e250 m\u003c\/strong\u003e transmission at \u003cstrong data-start=\"2482\" data-end=\"2493\"\u003e10 Mbps\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2498\" data-end=\"2538\"\u003e\n\u003cp data-start=\"2500\" data-end=\"2538\"\u003e\u003cem data-start=\"2500\" data-end=\"2538\"\u003eOnly active when Managed Mode is OFF\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2540\" data-end=\"2563\"\u003e\n\u003cp data-start=\"2542\" data-end=\"2563\"\u003e\u003cstrong data-start=\"2542\" data-end=\"2559\"\u003eReset Button:\u003c\/strong\u003e 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2565\" data-end=\"2568\"\u003e\n\u003ch2 data-start=\"2570\" data-end=\"2584\"\u003ePerformance\u003c\/h2\u003e\n\u003cul data-start=\"2585\" data-end=\"2736\"\u003e\n\u003cli data-start=\"2585\" data-end=\"2614\"\u003e\n\u003cp data-start=\"2587\" data-end=\"2614\"\u003e\u003cstrong data-start=\"2587\" data-end=\"2596\"\u003eMTBF:\u003c\/strong\u003e 2,482,955 hours\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2615\" data-end=\"2644\"\u003e\n\u003cp data-start=\"2617\" data-end=\"2644\"\u003e\u003cstrong data-start=\"2617\" data-end=\"2635\"\u003ePacket Buffer:\u003c\/strong\u003e 4 Mbit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2645\" data-end=\"2678\"\u003e\n\u003cp data-start=\"2647\" data-end=\"2678\"\u003e\u003cstrong data-start=\"2647\" data-end=\"2663\"\u003eJumbo Frame:\u003c\/strong\u003e 15,360 Bytes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2679\" data-end=\"2708\"\u003e\n\u003cp data-start=\"2681\" data-end=\"2708\"\u003e\u003cstrong data-start=\"2681\" data-end=\"2703\"\u003eMAC Address Table:\u003c\/strong\u003e 8K\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2709\" data-end=\"2736\"\u003e\n\u003cp data-start=\"2711\" data-end=\"2736\"\u003e\u003cstrong data-start=\"2711\" data-end=\"2731\"\u003eSupported VLANs:\u003c\/strong\u003e 32\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2738\" data-end=\"2741\"\u003e\n\u003ch2 data-start=\"2743\" data-end=\"2763\"\u003eNetwork Standards\u003c\/h2\u003e\n\u003cul data-start=\"2764\" data-end=\"2897\"\u003e\n\u003cli data-start=\"2764\" data-end=\"2897\"\u003e\n\u003cp data-start=\"2766\" data-end=\"2787\"\u003e\u003cstrong data-start=\"2766\" data-end=\"2785\"\u003eIEEE Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2790\" data-end=\"2897\"\u003e\n\u003cli data-start=\"2790\" data-end=\"2804\"\u003e\n\u003cp data-start=\"2792\" data-end=\"2804\"\u003eIEEE 802.3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2807\" data-end=\"2822\"\u003e\n\u003cp data-start=\"2809\" data-end=\"2822\"\u003eIEEE 802.3u\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2825\" data-end=\"2840\"\u003e\n\u003cp data-start=\"2827\" data-end=\"2840\"\u003eIEEE 802.3x\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2843\" data-end=\"2859\"\u003e\n\u003cp data-start=\"2845\" data-end=\"2859\"\u003eIEEE 802.3ab\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2862\" data-end=\"2878\"\u003e\n\u003cp data-start=\"2864\" data-end=\"2878\"\u003eIEEE 802.3az\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2881\" data-end=\"2897\"\u003e\n\u003cp data-start=\"2883\" data-end=\"2897\"\u003eIEEE 802.3ad\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2899\" data-end=\"2902\"\u003e\n\u003ch2 data-start=\"2904\" data-end=\"2923\"\u003eNetwork Features\u003c\/h2\u003e\n\u003cul data-start=\"2924\" data-end=\"3394\"\u003e\n\u003cli data-start=\"2924\" data-end=\"2967\"\u003e\n\u003cp data-start=\"2926\" data-end=\"2967\"\u003e\u003cstrong data-start=\"2926\" data-end=\"2955\"\u003eEthernet Loop Protection:\u003c\/strong\u003e STP, RSTP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2968\" data-end=\"2998\"\u003e\n\u003cp data-start=\"2970\" data-end=\"2998\"\u003e\u003cstrong data-start=\"2970\" data-end=\"2979\"\u003eVLAN:\u003c\/strong\u003e IEEE 802.1Q VLAN\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2999\" data-end=\"3043\"\u003e\n\u003cp data-start=\"3001\" data-end=\"3043\"\u003e\u003cstrong data-start=\"3001\" data-end=\"3022\"\u003eLink Aggregation:\u003c\/strong\u003e Static aggregation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3044\" data-end=\"3238\"\u003e\n\u003cp data-start=\"3046\" data-end=\"3066\"\u003e\u003cstrong data-start=\"3046\" data-end=\"3064\"\u003ePort Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3069\" data-end=\"3238\"\u003e\n\u003cli data-start=\"3069\" data-end=\"3097\"\u003e\n\u003cp data-start=\"3071\" data-end=\"3097\"\u003eIEEE 802.3x Flow Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3100\" data-end=\"3131\"\u003e\n\u003cp data-start=\"3102\" data-end=\"3131\"\u003eUnknown Unicast Suppression\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3134\" data-end=\"3161\"\u003e\n\u003cp data-start=\"3136\" data-end=\"3161\"\u003eMulticast Storm Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3164\" data-end=\"3191\"\u003e\n\u003cp data-start=\"3166\" data-end=\"3191\"\u003eBroadcast Storm Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3194\" data-end=\"3216\"\u003e\n\u003cp data-start=\"3196\" data-end=\"3216\"\u003eMAC + Port Binding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3219\" data-end=\"3238\"\u003e\n\u003cp data-start=\"3221\" data-end=\"3238\"\u003eLoop Prevention\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3239\" data-end=\"3309\"\u003e\n\u003cp data-start=\"3241\" data-end=\"3262\"\u003e\u003cstrong data-start=\"3241\" data-end=\"3260\"\u003ePort Mirroring:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3265\" data-end=\"3309\"\u003e\n\u003cli data-start=\"3265\" data-end=\"3289\"\u003e\n\u003cp data-start=\"3267\" data-end=\"3289\"\u003eLocal Port Mirroring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3292\" data-end=\"3309\"\u003e\n\u003cp data-start=\"3294\" data-end=\"3309\"\u003eN:1 Mirroring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3310\" data-end=\"3335\"\u003e\n\u003cp data-start=\"3312\" data-end=\"3335\"\u003e\u003cstrong data-start=\"3312\" data-end=\"3329\"\u003eLLDP Support:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3336\" data-end=\"3361\"\u003e\n\u003cp data-start=\"3338\" data-end=\"3361\"\u003e\u003cstrong data-start=\"3338\" data-end=\"3347\"\u003eDHCP:\u003c\/strong\u003e DHCP Client\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3362\" data-end=\"3394\"\u003e\n\u003cp data-start=\"3364\" data-end=\"3394\"\u003e\u003cstrong data-start=\"3364\" data-end=\"3377\"\u003eSecurity:\u003c\/strong\u003e Port Isolation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3396\" data-end=\"3399\"\u003e\n\u003ch2 data-start=\"3401\" data-end=\"3414\"\u003eManagement\u003c\/h2\u003e\n\u003cul data-start=\"3415\" data-end=\"3550\"\u003e\n\u003cli data-start=\"3415\" data-end=\"3486\"\u003e\n\u003cp data-start=\"3417\" data-end=\"3442\"\u003e\u003cstrong data-start=\"3417\" data-end=\"3440\"\u003eManagement Methods:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3445\" data-end=\"3486\"\u003e\n\u003cli data-start=\"3445\" data-end=\"3463\"\u003e\n\u003cp data-start=\"3447\" data-end=\"3463\"\u003eWeb Management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3466\" data-end=\"3486\"\u003e\n\u003cp data-start=\"3468\" data-end=\"3486\"\u003eCloud Management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3487\" data-end=\"3550\"\u003e\n\u003cp data-start=\"3489\" data-end=\"3520\"\u003e\u003cstrong data-start=\"3489\" data-end=\"3518\"\u003eMonitoring \u0026amp; Maintenance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3523\" data-end=\"3550\"\u003e\n\u003cli data-start=\"3523\" data-end=\"3531\"\u003e\n\u003cp data-start=\"3525\" data-end=\"3531\"\u003eLogs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3534\" data-end=\"3550\"\u003e\n\u003cp data-start=\"3536\" data-end=\"3550\"\u003eFault Alarms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3552\" data-end=\"3555\"\u003e\n\u003ch2 data-start=\"3557\" data-end=\"3570\"\u003eProtection\u003c\/h2\u003e\n\u003cul data-start=\"3571\" data-end=\"3734\"\u003e\n\u003cli data-start=\"3571\" data-end=\"3650\"\u003e\n\u003cp data-start=\"3573\" data-end=\"3594\"\u003e\u003cstrong data-start=\"3573\" data-end=\"3592\"\u003eESD Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3597\" data-end=\"3650\"\u003e\n\u003cli data-start=\"3597\" data-end=\"3620\"\u003e\n\u003cp data-start=\"3599\" data-end=\"3620\"\u003eAir Discharge: 8 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3623\" data-end=\"3650\"\u003e\n\u003cp data-start=\"3625\" data-end=\"3650\"\u003eContact Discharge: 6 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3651\" data-end=\"3734\"\u003e\n\u003cp data-start=\"3653\" data-end=\"3680\"\u003e\u003cstrong data-start=\"3653\" data-end=\"3678\"\u003eLightning Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3683\" data-end=\"3734\"\u003e\n\u003cli data-start=\"3683\" data-end=\"3704\"\u003e\n\u003cp data-start=\"3685\" data-end=\"3704\"\u003eCommon Mode: 6 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3707\" data-end=\"3734\"\u003e\n\u003cp data-start=\"3709\" data-end=\"3734\"\u003eDifferential Mode: 1 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3736\" data-end=\"3739\"\u003e\n\u003ch2 data-start=\"3741\" data-end=\"3767\"\u003ePhysical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"3768\" data-end=\"4041\"\u003e\n\u003cli data-start=\"3768\" data-end=\"3805\"\u003e\n\u003cp data-start=\"3770\" data-end=\"3805\"\u003e\u003cstrong data-start=\"3770\" data-end=\"3785\"\u003eNet Weight:\u003c\/strong\u003e 0.36 kg (0.79 lb)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3806\" data-end=\"3845\"\u003e\n\u003cp data-start=\"3808\" data-end=\"3845\"\u003e\u003cstrong data-start=\"3808\" data-end=\"3825\"\u003eGross Weight:\u003c\/strong\u003e 1.13 kg (2.49 lb)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3846\" data-end=\"3925\"\u003e\n\u003cp data-start=\"3848\" data-end=\"3873\"\u003e\u003cstrong data-start=\"3848\" data-end=\"3871\"\u003eProduct Dimensions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3876\" data-end=\"3925\"\u003e\n\u003cli data-start=\"3876\" data-end=\"3925\"\u003e\n\u003cp data-start=\"3878\" data-end=\"3925\"\u003e184.6 × 103.3 × 27 mm (7.27\" × 4.07\" × 1.06\")\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3926\" data-end=\"4004\"\u003e\n\u003cp data-start=\"3928\" data-end=\"3955\"\u003e\u003cstrong data-start=\"3928\" data-end=\"3953\"\u003ePackaging Dimensions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3958\" data-end=\"4004\"\u003e\n\u003cli data-start=\"3958\" data-end=\"4004\"\u003e\n\u003cp data-start=\"3960\" data-end=\"4004\"\u003e252 × 137 × 113 mm (9.92\" × 5.39\" × 4.45\")\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4005\" data-end=\"4041\"\u003e\n\u003cp data-start=\"4007\" data-end=\"4041\"\u003e\u003cstrong data-start=\"4007\" data-end=\"4027\"\u003eCasing Material:\u003c\/strong\u003e Sheet metal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4043\" data-end=\"4046\"\u003e\n\u003ch2 data-start=\"4048\" data-end=\"4063\"\u003eInstallation\u003c\/h2\u003e\n\u003cul data-start=\"4064\" data-end=\"4115\"\u003e\n\u003cli data-start=\"4064\" data-end=\"4115\"\u003e\n\u003cp data-start=\"4066\" data-end=\"4115\"\u003e\u003cstrong data-start=\"4066\" data-end=\"4087\"\u003eMounting Options:\u003c\/strong\u003e Desktop mount, Wall mount\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4117\" data-end=\"4120\"\u003e\n\u003ch2 data-start=\"4122\" data-end=\"4139\"\u003eCertifications\u003c\/h2\u003e\n\u003cul data-start=\"4140\" data-end=\"4148\"\u003e\n\u003cli data-start=\"4140\" data-end=\"4148\"\u003e\n\u003cp data-start=\"4142\" data-end=\"4148\"\u003e\u003cstrong data-start=\"4142\" data-end=\"4148\"\u003eCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4150\" data-end=\"4153\"\u003e\n\u003ch2 data-start=\"4155\" data-end=\"4170\"\u003ePacking List\u003c\/h2\u003e\n\u003cul data-start=\"4171\" data-end=\"4272\"\u003e\n\u003cli data-start=\"4171\" data-end=\"4190\"\u003e\n\u003cp data-start=\"4173\" data-end=\"4190\"\u003e1 × User Manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4191\" data-end=\"4231\"\u003e\n\u003cp data-start=\"4193\" data-end=\"4231\"\u003e1 × Legal and Regulatory Information\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4232\" data-end=\"4253\"\u003e\n\u003cp data-start=\"4234\" data-end=\"4253\"\u003e1 × Power Adapter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4254\" data-end=\"4272\"\u003e\n\u003cp data-start=\"4256\" data-end=\"4272\"\u003e1 × Power Cord\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 3 Year Dahua ANZ Manufacturer Warranty\u003c\/p\u003e"}
Translation missing: en.products.product.regular_price $500.12 -
-
{"id":8191822069849,"title":"Dahua CS4010-8GT-110 10-Port Cloud Managed Desktop Gigabit Switch with 8-Port POE","handle":"cs4010-8gt-110-dahua-10-port-cloud-managed-desktop-gigabit-switch-with-8-port-poe","description":"\u003ch2 data-start=\"153\" data-end=\"220\"\u003e10-Port Cloud Managed Desktop \u003cstrong data-start=\"186\" data-end=\"197\"\u003eGigabit\u003c\/strong\u003e Switch with 8-Port PoE\u003c\/h2\u003e\n\u003ch3 data-start=\"222\" data-end=\"238\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"239\" data-end=\"804\"\u003e\n\u003cli data-start=\"239\" data-end=\"308\"\u003e\n\u003cp data-start=\"241\" data-end=\"308\"\u003e\u003cstrong data-start=\"241\" data-end=\"272\"\u003e8 × RJ-45 Gigabit PoE ports\u003c\/strong\u003e, \u003cstrong data-start=\"274\" data-end=\"308\"\u003e2 × RJ-45 Gigabit uplink ports\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"309\" data-end=\"432\"\u003e\n\u003cp data-start=\"311\" data-end=\"339\"\u003e\u003cstrong data-start=\"311\" data-end=\"337\"\u003e110 W total PoE budget\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"342\" data-end=\"432\"\u003e\n\u003cli data-start=\"342\" data-end=\"378\"\u003e\n\u003cp data-start=\"344\" data-end=\"378\"\u003eIEEE 802.3af\/at on all PoE ports\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"381\" data-end=\"432\"\u003e\n\u003cp data-start=\"383\" data-end=\"432\"\u003e\u003cstrong data-start=\"383\" data-end=\"432\"\u003eIEEE 802.3bt support on Ports 1–2 (red ports)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"433\" data-end=\"552\"\u003e\n\u003cp data-start=\"435\" data-end=\"474\"\u003e\u003cstrong data-start=\"435\" data-end=\"449\"\u003eDIP switch\u003c\/strong\u003e for fast mode switching:\u003c\/p\u003e\n\u003cul data-start=\"477\" data-end=\"552\"\u003e\n\u003cli data-start=\"477\" data-end=\"511\"\u003e\n\u003cp data-start=\"479\" data-end=\"511\"\u003eCloud-Managed \/ Unmanaged Mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"514\" data-end=\"530\"\u003e\n\u003cp data-start=\"516\" data-end=\"530\"\u003ePoE Watchdog\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"533\" data-end=\"552\"\u003e\n\u003cp data-start=\"535\" data-end=\"552\"\u003eLong-Distance PoE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"553\" data-end=\"603\"\u003e\n\u003cp data-start=\"555\" data-end=\"603\"\u003e\u003cstrong data-start=\"555\" data-end=\"586\"\u003eWide operating temperature:\u003c\/strong\u003e –10 °C to +55 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"604\" data-end=\"660\"\u003e\n\u003cp data-start=\"606\" data-end=\"660\"\u003eSupports \u003cstrong data-start=\"615\" data-end=\"634\"\u003eVLAN, STP, RSTP\u003c\/strong\u003e, and \u003cstrong data-start=\"640\" data-end=\"660\"\u003elink aggregation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"661\" data-end=\"734\"\u003e\n\u003cp data-start=\"663\" data-end=\"734\"\u003e\u003cstrong data-start=\"663\" data-end=\"678\"\u003eWeb-managed\u003c\/strong\u003e and \u003cstrong data-start=\"683\" data-end=\"715\"\u003ecentralised cloud management\u003c\/strong\u003e via \u003cstrong data-start=\"720\" data-end=\"734\"\u003eDoLynk App\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"735\" data-end=\"804\"\u003e\n\u003cp data-start=\"737\" data-end=\"804\"\u003eEasy configuration with \u003cstrong data-start=\"761\" data-end=\"804\"\u003eauto network detection and system setup\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"735\" data-end=\"804\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0047\/9510\/5391\/files\/DH-CS4010-8GT-110_V2_datasheet_20251104.pdf?v=1765923577\"\u003e\u003cstrong data-start=\"761\" data-end=\"804\"\u003eDatasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"806\" data-end=\"809\"\u003e\n\u003ch2 data-start=\"811\" data-end=\"834\"\u003eBasic Specifications\u003c\/h2\u003e\n\u003cul data-start=\"835\" data-end=\"946\"\u003e\n\u003cli data-start=\"835\" data-end=\"867\"\u003e\n\u003cp data-start=\"837\" data-end=\"867\"\u003e\u003cstrong data-start=\"837\" data-end=\"857\"\u003eSwitching Layer:\u003c\/strong\u003e Layer 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"868\" data-end=\"903\"\u003e\n\u003cp data-start=\"870\" data-end=\"903\"\u003e\u003cstrong data-start=\"870\" data-end=\"893\"\u003eSwitching Capacity:\u003c\/strong\u003e 20 Gbps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"904\" data-end=\"946\"\u003e\n\u003cp data-start=\"906\" data-end=\"946\"\u003e\u003cstrong data-start=\"906\" data-end=\"933\"\u003ePacket Forwarding Rate:\u003c\/strong\u003e 14.88 Mpps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"948\" data-end=\"951\"\u003e\n\u003ch2 data-start=\"953\" data-end=\"974\"\u003ePort Configuration\u003c\/h2\u003e\n\u003cul data-start=\"975\" data-end=\"1090\"\u003e\n\u003cli data-start=\"975\" data-end=\"1026\"\u003e\n\u003cp data-start=\"977\" data-end=\"1026\"\u003e\u003cstrong data-start=\"977\" data-end=\"991\"\u003ePorts 1–8:\u003c\/strong\u003e 8 × RJ-45 10\/100\/1000 Mbps (PoE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1027\" data-end=\"1090\"\u003e\n\u003cp data-start=\"1029\" data-end=\"1090\"\u003e\u003cstrong data-start=\"1029\" data-end=\"1044\"\u003ePorts 9–10:\u003c\/strong\u003e 2 × RJ-45 10\/100\/1000 Mbps (Gigabit uplink)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1092\" data-end=\"1095\"\u003e\n\u003ch2 data-start=\"1097\" data-end=\"1128\"\u003eEnvironmental Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1129\" data-end=\"1371\"\u003e\n\u003cli data-start=\"1129\" data-end=\"1196\"\u003e\n\u003cp data-start=\"1131\" data-end=\"1196\"\u003e\u003cstrong data-start=\"1131\" data-end=\"1157\"\u003eOperating Temperature:\u003c\/strong\u003e –10 °C to +55 °C (+14 °F to +131 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1197\" data-end=\"1252\"\u003e\n\u003cp data-start=\"1199\" data-end=\"1252\"\u003e\u003cstrong data-start=\"1199\" data-end=\"1222\"\u003eOperating Humidity:\u003c\/strong\u003e 10%–90% RH (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1253\" data-end=\"1318\"\u003e\n\u003cp data-start=\"1255\" data-end=\"1318\"\u003e\u003cstrong data-start=\"1255\" data-end=\"1279\"\u003eStorage Temperature:\u003c\/strong\u003e –40 °C to +75 °C (–40 °F to +167 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1319\" data-end=\"1371\"\u003e\n\u003cp data-start=\"1321\" data-end=\"1371\"\u003e\u003cstrong data-start=\"1321\" data-end=\"1342\"\u003eStorage Humidity:\u003c\/strong\u003e 5%–95% RH (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1373\" data-end=\"1376\"\u003e\n\u003ch2 data-start=\"1378\" data-end=\"1386\"\u003ePower\u003c\/h2\u003e\n\u003cul data-start=\"1387\" data-end=\"1516\"\u003e\n\u003cli data-start=\"1387\" data-end=\"1448\"\u003e\n\u003cp data-start=\"1389\" data-end=\"1448\"\u003e\u003cstrong data-start=\"1389\" data-end=\"1406\"\u003ePower Supply:\u003c\/strong\u003e External power adapter, 54 VDC \/ 2.22 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1449\" data-end=\"1516\"\u003e\n\u003cp data-start=\"1451\" data-end=\"1475\"\u003e\u003cstrong data-start=\"1451\" data-end=\"1473\"\u003ePower Consumption:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1478\" data-end=\"1516\"\u003e\n\u003cli data-start=\"1478\" data-end=\"1493\"\u003e\n\u003cp data-start=\"1480\" data-end=\"1493\"\u003eIdle: 5.7 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1496\" data-end=\"1516\"\u003e\n\u003cp data-start=\"1498\" data-end=\"1516\"\u003eFull Load: 115 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1518\" data-end=\"1521\"\u003e\n\u003ch2 data-start=\"1523\" data-end=\"1544\"\u003ePoE Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1545\" data-end=\"2096\"\u003e\n\u003cli data-start=\"1545\" data-end=\"1569\"\u003e\n\u003cp data-start=\"1547\" data-end=\"1569\"\u003e\u003cstrong data-start=\"1547\" data-end=\"1563\"\u003ePoE Support:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1570\" data-end=\"1644\"\u003e\n\u003cp data-start=\"1572\" data-end=\"1644\"\u003e\u003cstrong data-start=\"1572\" data-end=\"1590\"\u003ePoE Protocols:\u003c\/strong\u003e IEEE 802.3af \/ IEEE 802.3at \/ Hi-PoE \/ IEEE 802.3bt\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1645\" data-end=\"1772\"\u003e\n\u003cp data-start=\"1647\" data-end=\"1670\"\u003e\u003cstrong data-start=\"1647\" data-end=\"1668\"\u003ePoE Output Power:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1673\" data-end=\"1772\"\u003e\n\u003cli data-start=\"1673\" data-end=\"1703\"\u003e\n\u003cp data-start=\"1675\" data-end=\"1703\"\u003ePorts 1–2: ≤ 90 W per port\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1706\" data-end=\"1736\"\u003e\n\u003cp data-start=\"1708\" data-end=\"1736\"\u003ePorts 3–8: ≤ 30 W per port\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1739\" data-end=\"1772\"\u003e\n\u003cp data-start=\"1741\" data-end=\"1772\"\u003e\u003cstrong data-start=\"1741\" data-end=\"1762\"\u003eTotal PoE Budget:\u003c\/strong\u003e ≤ 110 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1773\" data-end=\"1915\"\u003e\n\u003cp data-start=\"1775\" data-end=\"1802\"\u003e\u003cstrong data-start=\"1775\" data-end=\"1800\"\u003ePoE Power Management:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1805\" data-end=\"1915\"\u003e\n\u003cli data-start=\"1805\" data-end=\"1841\"\u003e\n\u003cp data-start=\"1807\" data-end=\"1841\"\u003ePoE power consumption management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1844\" data-end=\"1864\"\u003e\n\u003cp data-start=\"1846\" data-end=\"1864\"\u003ePoE power on\/off\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1867\" data-end=\"1915\"\u003e\n\u003cp data-start=\"1869\" data-end=\"1915\"\u003eAutomatic PoE shutdown on overload detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1916\" data-end=\"2065\"\u003e\n\u003cp data-start=\"1918\" data-end=\"1943\"\u003e\u003cstrong data-start=\"1918\" data-end=\"1941\"\u003ePoE Pin Assignment:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1946\" data-end=\"2065\"\u003e\n\u003cli data-start=\"1946\" data-end=\"2010\"\u003e\n\u003cp data-start=\"1948\" data-end=\"1964\"\u003e\u003cstrong data-start=\"1948\" data-end=\"1962\"\u003ePorts 1–2:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1969\" data-end=\"2010\"\u003e\n\u003cli data-start=\"1969\" data-end=\"1987\"\u003e\n\u003cp data-start=\"1971\" data-end=\"1987\"\u003eV+: 1, 2, 4, 5\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1992\" data-end=\"2010\"\u003e\n\u003cp data-start=\"1994\" data-end=\"2010\"\u003eV–: 3, 6, 7, 8\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2013\" data-end=\"2065\"\u003e\n\u003cp data-start=\"2015\" data-end=\"2031\"\u003e\u003cstrong data-start=\"2015\" data-end=\"2029\"\u003ePorts 3–8:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2036\" data-end=\"2065\"\u003e\n\u003cli data-start=\"2036\" data-end=\"2048\"\u003e\n\u003cp data-start=\"2038\" data-end=\"2048\"\u003eV+: 1, 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2053\" data-end=\"2065\"\u003e\n\u003cp data-start=\"2055\" data-end=\"2065\"\u003eV–: 3, 6\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2066\" data-end=\"2096\"\u003e\n\u003cp data-start=\"2068\" data-end=\"2096\"\u003e\u003cstrong data-start=\"2068\" data-end=\"2090\"\u003eLong-Distance PoE:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2098\" data-end=\"2101\"\u003e\n\u003ch2 data-start=\"2103\" data-end=\"2123\"\u003eHardware Features\u003c\/h2\u003e\n\u003ch3 data-start=\"2124\" data-end=\"2148\"\u003eDIP Switch Functions\u003c\/h3\u003e\n\u003cul data-start=\"2149\" data-end=\"2563\"\u003e\n\u003cli data-start=\"2149\" data-end=\"2243\"\u003e\n\u003cp data-start=\"2151\" data-end=\"2170\"\u003e\u003cstrong data-start=\"2151\" data-end=\"2168\"\u003eManaged Mode:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2173\" data-end=\"2243\"\u003e\n\u003cli data-start=\"2173\" data-end=\"2219\"\u003e\n\u003cp data-start=\"2175\" data-end=\"2219\"\u003eON (default): Local web + cloud management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2222\" data-end=\"2243\"\u003e\n\u003cp data-start=\"2224\" data-end=\"2243\"\u003eOFF: Unmanaged mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2244\" data-end=\"2406\"\u003e\n\u003cp data-start=\"2246\" data-end=\"2265\"\u003e\u003cstrong data-start=\"2246\" data-end=\"2263\"\u003ePoE Watchdog:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2268\" data-end=\"2406\"\u003e\n\u003cli data-start=\"2268\" data-end=\"2290\"\u003e\n\u003cp data-start=\"2270\" data-end=\"2290\"\u003eMonitors ports 1–8\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2293\" data-end=\"2363\"\u003e\n\u003cp data-start=\"2295\" data-end=\"2363\"\u003eAutomatically restarts PoE if no traffic is detected for 2 minutes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2366\" data-end=\"2406\"\u003e\n\u003cp data-start=\"2368\" data-end=\"2406\"\u003e\u003cem data-start=\"2368\" data-end=\"2406\"\u003eOnly active when Managed Mode is OFF\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2407\" data-end=\"2538\"\u003e\n\u003cp data-start=\"2409\" data-end=\"2427\"\u003e\u003cstrong data-start=\"2409\" data-end=\"2425\"\u003eExtend Mode:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2430\" data-end=\"2538\"\u003e\n\u003cli data-start=\"2430\" data-end=\"2495\"\u003e\n\u003cp data-start=\"2432\" data-end=\"2495\"\u003ePorts 1–8 support up to \u003cstrong data-start=\"2456\" data-end=\"2465\"\u003e250 m\u003c\/strong\u003e transmission at \u003cstrong data-start=\"2482\" data-end=\"2493\"\u003e10 Mbps\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2498\" data-end=\"2538\"\u003e\n\u003cp data-start=\"2500\" data-end=\"2538\"\u003e\u003cem data-start=\"2500\" data-end=\"2538\"\u003eOnly active when Managed Mode is OFF\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2540\" data-end=\"2563\"\u003e\n\u003cp data-start=\"2542\" data-end=\"2563\"\u003e\u003cstrong data-start=\"2542\" data-end=\"2559\"\u003eReset Button:\u003c\/strong\u003e 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2565\" data-end=\"2568\"\u003e\n\u003ch2 data-start=\"2570\" data-end=\"2584\"\u003ePerformance\u003c\/h2\u003e\n\u003cul data-start=\"2585\" data-end=\"2736\"\u003e\n\u003cli data-start=\"2585\" data-end=\"2614\"\u003e\n\u003cp data-start=\"2587\" data-end=\"2614\"\u003e\u003cstrong data-start=\"2587\" data-end=\"2596\"\u003eMTBF:\u003c\/strong\u003e 2,482,955 hours\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2615\" data-end=\"2644\"\u003e\n\u003cp data-start=\"2617\" data-end=\"2644\"\u003e\u003cstrong data-start=\"2617\" data-end=\"2635\"\u003ePacket Buffer:\u003c\/strong\u003e 4 Mbit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2645\" data-end=\"2678\"\u003e\n\u003cp data-start=\"2647\" data-end=\"2678\"\u003e\u003cstrong data-start=\"2647\" data-end=\"2663\"\u003eJumbo Frame:\u003c\/strong\u003e 15,360 Bytes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2679\" data-end=\"2708\"\u003e\n\u003cp data-start=\"2681\" data-end=\"2708\"\u003e\u003cstrong data-start=\"2681\" data-end=\"2703\"\u003eMAC Address Table:\u003c\/strong\u003e 8K\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2709\" data-end=\"2736\"\u003e\n\u003cp data-start=\"2711\" data-end=\"2736\"\u003e\u003cstrong data-start=\"2711\" data-end=\"2731\"\u003eSupported VLANs:\u003c\/strong\u003e 32\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2738\" data-end=\"2741\"\u003e\n\u003ch2 data-start=\"2743\" data-end=\"2763\"\u003eNetwork Standards\u003c\/h2\u003e\n\u003cul data-start=\"2764\" data-end=\"2897\"\u003e\n\u003cli data-start=\"2764\" data-end=\"2897\"\u003e\n\u003cp data-start=\"2766\" data-end=\"2787\"\u003e\u003cstrong data-start=\"2766\" data-end=\"2785\"\u003eIEEE Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2790\" data-end=\"2897\"\u003e\n\u003cli data-start=\"2790\" data-end=\"2804\"\u003e\n\u003cp data-start=\"2792\" data-end=\"2804\"\u003eIEEE 802.3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2807\" data-end=\"2822\"\u003e\n\u003cp data-start=\"2809\" data-end=\"2822\"\u003eIEEE 802.3u\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2825\" data-end=\"2840\"\u003e\n\u003cp data-start=\"2827\" data-end=\"2840\"\u003eIEEE 802.3x\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2843\" data-end=\"2859\"\u003e\n\u003cp data-start=\"2845\" data-end=\"2859\"\u003eIEEE 802.3ab\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2862\" data-end=\"2878\"\u003e\n\u003cp data-start=\"2864\" data-end=\"2878\"\u003eIEEE 802.3az\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2881\" data-end=\"2897\"\u003e\n\u003cp data-start=\"2883\" data-end=\"2897\"\u003eIEEE 802.3ad\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2899\" data-end=\"2902\"\u003e\n\u003ch2 data-start=\"2904\" data-end=\"2923\"\u003eNetwork Features\u003c\/h2\u003e\n\u003cul data-start=\"2924\" data-end=\"3394\"\u003e\n\u003cli data-start=\"2924\" data-end=\"2967\"\u003e\n\u003cp data-start=\"2926\" data-end=\"2967\"\u003e\u003cstrong data-start=\"2926\" data-end=\"2955\"\u003eEthernet Loop Protection:\u003c\/strong\u003e STP, RSTP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2968\" data-end=\"2998\"\u003e\n\u003cp data-start=\"2970\" data-end=\"2998\"\u003e\u003cstrong data-start=\"2970\" data-end=\"2979\"\u003eVLAN:\u003c\/strong\u003e IEEE 802.1Q VLAN\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2999\" data-end=\"3043\"\u003e\n\u003cp data-start=\"3001\" data-end=\"3043\"\u003e\u003cstrong data-start=\"3001\" data-end=\"3022\"\u003eLink Aggregation:\u003c\/strong\u003e Static aggregation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3044\" data-end=\"3238\"\u003e\n\u003cp data-start=\"3046\" data-end=\"3066\"\u003e\u003cstrong data-start=\"3046\" data-end=\"3064\"\u003ePort Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3069\" data-end=\"3238\"\u003e\n\u003cli data-start=\"3069\" data-end=\"3097\"\u003e\n\u003cp data-start=\"3071\" data-end=\"3097\"\u003eIEEE 802.3x Flow Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3100\" data-end=\"3131\"\u003e\n\u003cp data-start=\"3102\" data-end=\"3131\"\u003eUnknown Unicast Suppression\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3134\" data-end=\"3161\"\u003e\n\u003cp data-start=\"3136\" data-end=\"3161\"\u003eMulticast Storm Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3164\" data-end=\"3191\"\u003e\n\u003cp data-start=\"3166\" data-end=\"3191\"\u003eBroadcast Storm Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3194\" data-end=\"3216\"\u003e\n\u003cp data-start=\"3196\" data-end=\"3216\"\u003eMAC + Port Binding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3219\" data-end=\"3238\"\u003e\n\u003cp data-start=\"3221\" data-end=\"3238\"\u003eLoop Prevention\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3239\" data-end=\"3309\"\u003e\n\u003cp data-start=\"3241\" data-end=\"3262\"\u003e\u003cstrong data-start=\"3241\" data-end=\"3260\"\u003ePort Mirroring:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3265\" data-end=\"3309\"\u003e\n\u003cli data-start=\"3265\" data-end=\"3289\"\u003e\n\u003cp data-start=\"3267\" data-end=\"3289\"\u003eLocal Port Mirroring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3292\" data-end=\"3309\"\u003e\n\u003cp data-start=\"3294\" data-end=\"3309\"\u003eN:1 Mirroring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3310\" data-end=\"3335\"\u003e\n\u003cp data-start=\"3312\" data-end=\"3335\"\u003e\u003cstrong data-start=\"3312\" data-end=\"3329\"\u003eLLDP Support:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3336\" data-end=\"3361\"\u003e\n\u003cp data-start=\"3338\" data-end=\"3361\"\u003e\u003cstrong data-start=\"3338\" data-end=\"3347\"\u003eDHCP:\u003c\/strong\u003e DHCP Client\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3362\" data-end=\"3394\"\u003e\n\u003cp data-start=\"3364\" data-end=\"3394\"\u003e\u003cstrong data-start=\"3364\" data-end=\"3377\"\u003eSecurity:\u003c\/strong\u003e Port Isolation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3396\" data-end=\"3399\"\u003e\n\u003ch2 data-start=\"3401\" data-end=\"3414\"\u003eManagement\u003c\/h2\u003e\n\u003cul data-start=\"3415\" data-end=\"3550\"\u003e\n\u003cli data-start=\"3415\" data-end=\"3486\"\u003e\n\u003cp data-start=\"3417\" data-end=\"3442\"\u003e\u003cstrong data-start=\"3417\" data-end=\"3440\"\u003eManagement Methods:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3445\" data-end=\"3486\"\u003e\n\u003cli data-start=\"3445\" data-end=\"3463\"\u003e\n\u003cp data-start=\"3447\" data-end=\"3463\"\u003eWeb Management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3466\" data-end=\"3486\"\u003e\n\u003cp data-start=\"3468\" data-end=\"3486\"\u003eCloud Management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3487\" data-end=\"3550\"\u003e\n\u003cp data-start=\"3489\" data-end=\"3520\"\u003e\u003cstrong data-start=\"3489\" data-end=\"3518\"\u003eMonitoring \u0026amp; Maintenance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3523\" data-end=\"3550\"\u003e\n\u003cli data-start=\"3523\" data-end=\"3531\"\u003e\n\u003cp data-start=\"3525\" data-end=\"3531\"\u003eLogs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3534\" data-end=\"3550\"\u003e\n\u003cp data-start=\"3536\" data-end=\"3550\"\u003eFault Alarms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3552\" data-end=\"3555\"\u003e\n\u003ch2 data-start=\"3557\" data-end=\"3570\"\u003eProtection\u003c\/h2\u003e\n\u003cul data-start=\"3571\" data-end=\"3734\"\u003e\n\u003cli data-start=\"3571\" data-end=\"3650\"\u003e\n\u003cp data-start=\"3573\" data-end=\"3594\"\u003e\u003cstrong data-start=\"3573\" data-end=\"3592\"\u003eESD Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3597\" data-end=\"3650\"\u003e\n\u003cli data-start=\"3597\" data-end=\"3620\"\u003e\n\u003cp data-start=\"3599\" data-end=\"3620\"\u003eAir Discharge: 8 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3623\" data-end=\"3650\"\u003e\n\u003cp data-start=\"3625\" data-end=\"3650\"\u003eContact Discharge: 6 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3651\" data-end=\"3734\"\u003e\n\u003cp data-start=\"3653\" data-end=\"3680\"\u003e\u003cstrong data-start=\"3653\" data-end=\"3678\"\u003eLightning Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3683\" data-end=\"3734\"\u003e\n\u003cli data-start=\"3683\" data-end=\"3704\"\u003e\n\u003cp data-start=\"3685\" data-end=\"3704\"\u003eCommon Mode: 6 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3707\" data-end=\"3734\"\u003e\n\u003cp data-start=\"3709\" data-end=\"3734\"\u003eDifferential Mode: 1 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3736\" data-end=\"3739\"\u003e\n\u003ch2 data-start=\"3741\" data-end=\"3767\"\u003ePhysical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"3768\" data-end=\"4041\"\u003e\n\u003cli data-start=\"3768\" data-end=\"3805\"\u003e\n\u003cp data-start=\"3770\" data-end=\"3805\"\u003e\u003cstrong data-start=\"3770\" data-end=\"3785\"\u003eNet Weight:\u003c\/strong\u003e 0.36 kg (0.79 lb)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3806\" data-end=\"3845\"\u003e\n\u003cp data-start=\"3808\" data-end=\"3845\"\u003e\u003cstrong data-start=\"3808\" data-end=\"3825\"\u003eGross Weight:\u003c\/strong\u003e 1.13 kg (2.49 lb)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3846\" data-end=\"3925\"\u003e\n\u003cp data-start=\"3848\" data-end=\"3873\"\u003e\u003cstrong data-start=\"3848\" data-end=\"3871\"\u003eProduct Dimensions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3876\" data-end=\"3925\"\u003e\n\u003cli data-start=\"3876\" data-end=\"3925\"\u003e\n\u003cp data-start=\"3878\" data-end=\"3925\"\u003e184.6 × 103.3 × 27 mm (7.27\" × 4.07\" × 1.06\")\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3926\" data-end=\"4004\"\u003e\n\u003cp data-start=\"3928\" data-end=\"3955\"\u003e\u003cstrong data-start=\"3928\" data-end=\"3953\"\u003ePackaging Dimensions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3958\" data-end=\"4004\"\u003e\n\u003cli data-start=\"3958\" data-end=\"4004\"\u003e\n\u003cp data-start=\"3960\" data-end=\"4004\"\u003e252 × 137 × 113 mm (9.92\" × 5.39\" × 4.45\")\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4005\" data-end=\"4041\"\u003e\n\u003cp data-start=\"4007\" data-end=\"4041\"\u003e\u003cstrong data-start=\"4007\" data-end=\"4027\"\u003eCasing Material:\u003c\/strong\u003e Sheet metal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4043\" data-end=\"4046\"\u003e\n\u003ch2 data-start=\"4048\" data-end=\"4063\"\u003eInstallation\u003c\/h2\u003e\n\u003cul data-start=\"4064\" data-end=\"4115\"\u003e\n\u003cli data-start=\"4064\" data-end=\"4115\"\u003e\n\u003cp data-start=\"4066\" data-end=\"4115\"\u003e\u003cstrong data-start=\"4066\" data-end=\"4087\"\u003eMounting Options:\u003c\/strong\u003e Desktop mount, Wall mount\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4117\" data-end=\"4120\"\u003e\n\u003ch2 data-start=\"4122\" data-end=\"4139\"\u003eCertifications\u003c\/h2\u003e\n\u003cul data-start=\"4140\" data-end=\"4148\"\u003e\n\u003cli data-start=\"4140\" data-end=\"4148\"\u003e\n\u003cp data-start=\"4142\" data-end=\"4148\"\u003e\u003cstrong data-start=\"4142\" data-end=\"4148\"\u003eCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4150\" data-end=\"4153\"\u003e\n\u003ch2 data-start=\"4155\" data-end=\"4170\"\u003ePacking List\u003c\/h2\u003e\n\u003cul data-start=\"4171\" data-end=\"4272\"\u003e\n\u003cli data-start=\"4171\" data-end=\"4190\"\u003e\n\u003cp data-start=\"4173\" data-end=\"4190\"\u003e1 × User Manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4191\" data-end=\"4231\"\u003e\n\u003cp data-start=\"4193\" data-end=\"4231\"\u003e1 × Legal and Regulatory Information\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4232\" data-end=\"4253\"\u003e\n\u003cp data-start=\"4234\" data-end=\"4253\"\u003e1 × Power Adapter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4254\" data-end=\"4272\"\u003e\n\u003cp data-start=\"4256\" data-end=\"4272\"\u003e1 × Power Cord\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 3 Year Dahua ANZ Manufacturer Warranty\u003c\/p\u003e","published_at":"2026-04-15T12:20:03+10:00","created_at":"2026-04-15T12:20:05+10:00","vendor":"Dahua","type":"Dahua PoE Switch","tags":["Australian Warranty","brand-Dahua","CCTV","Dahua","Dahua PoE Switch","DH-CS4010-8GT-110","Network Switch","PoE","PoE Switch","Security","Security Camera","Tekcart","type-Switch"],"price":23256,"price_min":23256,"price_max":23256,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":43221619703897,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"DH-CS4010-8GT-110","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Dahua CS4010-8GT-110 10-Port Cloud Managed Desktop Gigabit Switch with 8-Port POE","public_title":null,"options":["Default Title"],"price":23256,"weight":0,"compare_at_price":null,"inventory_management":"shopify","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/tekcart.com.au\/cdn\/shop\/files\/CS4010-8GT-110.png?v=1776219605"],"featured_image":"\/\/tekcart.com.au\/cdn\/shop\/files\/CS4010-8GT-110.png?v=1776219605","options":["Title"],"media":[{"alt":null,"id":28080822911065,"position":1,"preview_image":{"aspect_ratio":1.531,"height":1092,"width":1672,"src":"\/\/tekcart.com.au\/cdn\/shop\/files\/CS4010-8GT-110.png?v=1776219605"},"aspect_ratio":1.531,"height":1092,"media_type":"image","src":"\/\/tekcart.com.au\/cdn\/shop\/files\/CS4010-8GT-110.png?v=1776219605","width":1672}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch2 data-start=\"153\" data-end=\"220\"\u003e10-Port Cloud Managed Desktop \u003cstrong data-start=\"186\" data-end=\"197\"\u003eGigabit\u003c\/strong\u003e Switch with 8-Port PoE\u003c\/h2\u003e\n\u003ch3 data-start=\"222\" data-end=\"238\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"239\" data-end=\"804\"\u003e\n\u003cli data-start=\"239\" data-end=\"308\"\u003e\n\u003cp data-start=\"241\" data-end=\"308\"\u003e\u003cstrong data-start=\"241\" data-end=\"272\"\u003e8 × RJ-45 Gigabit PoE ports\u003c\/strong\u003e, \u003cstrong data-start=\"274\" data-end=\"308\"\u003e2 × RJ-45 Gigabit uplink ports\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"309\" data-end=\"432\"\u003e\n\u003cp data-start=\"311\" data-end=\"339\"\u003e\u003cstrong data-start=\"311\" data-end=\"337\"\u003e110 W total PoE budget\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"342\" data-end=\"432\"\u003e\n\u003cli data-start=\"342\" data-end=\"378\"\u003e\n\u003cp data-start=\"344\" data-end=\"378\"\u003eIEEE 802.3af\/at on all PoE ports\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"381\" data-end=\"432\"\u003e\n\u003cp data-start=\"383\" data-end=\"432\"\u003e\u003cstrong data-start=\"383\" data-end=\"432\"\u003eIEEE 802.3bt support on Ports 1–2 (red ports)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"433\" data-end=\"552\"\u003e\n\u003cp data-start=\"435\" data-end=\"474\"\u003e\u003cstrong data-start=\"435\" data-end=\"449\"\u003eDIP switch\u003c\/strong\u003e for fast mode switching:\u003c\/p\u003e\n\u003cul data-start=\"477\" data-end=\"552\"\u003e\n\u003cli data-start=\"477\" data-end=\"511\"\u003e\n\u003cp data-start=\"479\" data-end=\"511\"\u003eCloud-Managed \/ Unmanaged Mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"514\" data-end=\"530\"\u003e\n\u003cp data-start=\"516\" data-end=\"530\"\u003ePoE Watchdog\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"533\" data-end=\"552\"\u003e\n\u003cp data-start=\"535\" data-end=\"552\"\u003eLong-Distance PoE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"553\" data-end=\"603\"\u003e\n\u003cp data-start=\"555\" data-end=\"603\"\u003e\u003cstrong data-start=\"555\" data-end=\"586\"\u003eWide operating temperature:\u003c\/strong\u003e –10 °C to +55 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"604\" data-end=\"660\"\u003e\n\u003cp data-start=\"606\" data-end=\"660\"\u003eSupports \u003cstrong data-start=\"615\" data-end=\"634\"\u003eVLAN, STP, RSTP\u003c\/strong\u003e, and \u003cstrong data-start=\"640\" data-end=\"660\"\u003elink aggregation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"661\" data-end=\"734\"\u003e\n\u003cp data-start=\"663\" data-end=\"734\"\u003e\u003cstrong data-start=\"663\" data-end=\"678\"\u003eWeb-managed\u003c\/strong\u003e and \u003cstrong data-start=\"683\" data-end=\"715\"\u003ecentralised cloud management\u003c\/strong\u003e via \u003cstrong data-start=\"720\" data-end=\"734\"\u003eDoLynk App\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"735\" data-end=\"804\"\u003e\n\u003cp data-start=\"737\" data-end=\"804\"\u003eEasy configuration with \u003cstrong data-start=\"761\" data-end=\"804\"\u003eauto network detection and system setup\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"735\" data-end=\"804\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0047\/9510\/5391\/files\/DH-CS4010-8GT-110_V2_datasheet_20251104.pdf?v=1765923577\"\u003e\u003cstrong data-start=\"761\" data-end=\"804\"\u003eDatasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"806\" data-end=\"809\"\u003e\n\u003ch2 data-start=\"811\" data-end=\"834\"\u003eBasic Specifications\u003c\/h2\u003e\n\u003cul data-start=\"835\" data-end=\"946\"\u003e\n\u003cli data-start=\"835\" data-end=\"867\"\u003e\n\u003cp data-start=\"837\" data-end=\"867\"\u003e\u003cstrong data-start=\"837\" data-end=\"857\"\u003eSwitching Layer:\u003c\/strong\u003e Layer 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"868\" data-end=\"903\"\u003e\n\u003cp data-start=\"870\" data-end=\"903\"\u003e\u003cstrong data-start=\"870\" data-end=\"893\"\u003eSwitching Capacity:\u003c\/strong\u003e 20 Gbps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"904\" data-end=\"946\"\u003e\n\u003cp data-start=\"906\" data-end=\"946\"\u003e\u003cstrong data-start=\"906\" data-end=\"933\"\u003ePacket Forwarding Rate:\u003c\/strong\u003e 14.88 Mpps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"948\" data-end=\"951\"\u003e\n\u003ch2 data-start=\"953\" data-end=\"974\"\u003ePort Configuration\u003c\/h2\u003e\n\u003cul data-start=\"975\" data-end=\"1090\"\u003e\n\u003cli data-start=\"975\" data-end=\"1026\"\u003e\n\u003cp data-start=\"977\" data-end=\"1026\"\u003e\u003cstrong data-start=\"977\" data-end=\"991\"\u003ePorts 1–8:\u003c\/strong\u003e 8 × RJ-45 10\/100\/1000 Mbps (PoE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1027\" data-end=\"1090\"\u003e\n\u003cp data-start=\"1029\" data-end=\"1090\"\u003e\u003cstrong data-start=\"1029\" data-end=\"1044\"\u003ePorts 9–10:\u003c\/strong\u003e 2 × RJ-45 10\/100\/1000 Mbps (Gigabit uplink)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1092\" data-end=\"1095\"\u003e\n\u003ch2 data-start=\"1097\" data-end=\"1128\"\u003eEnvironmental Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1129\" data-end=\"1371\"\u003e\n\u003cli data-start=\"1129\" data-end=\"1196\"\u003e\n\u003cp data-start=\"1131\" data-end=\"1196\"\u003e\u003cstrong data-start=\"1131\" data-end=\"1157\"\u003eOperating Temperature:\u003c\/strong\u003e –10 °C to +55 °C (+14 °F to +131 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1197\" data-end=\"1252\"\u003e\n\u003cp data-start=\"1199\" data-end=\"1252\"\u003e\u003cstrong data-start=\"1199\" data-end=\"1222\"\u003eOperating Humidity:\u003c\/strong\u003e 10%–90% RH (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1253\" data-end=\"1318\"\u003e\n\u003cp data-start=\"1255\" data-end=\"1318\"\u003e\u003cstrong data-start=\"1255\" data-end=\"1279\"\u003eStorage Temperature:\u003c\/strong\u003e –40 °C to +75 °C (–40 °F to +167 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1319\" data-end=\"1371\"\u003e\n\u003cp data-start=\"1321\" data-end=\"1371\"\u003e\u003cstrong data-start=\"1321\" data-end=\"1342\"\u003eStorage Humidity:\u003c\/strong\u003e 5%–95% RH (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1373\" data-end=\"1376\"\u003e\n\u003ch2 data-start=\"1378\" data-end=\"1386\"\u003ePower\u003c\/h2\u003e\n\u003cul data-start=\"1387\" data-end=\"1516\"\u003e\n\u003cli data-start=\"1387\" data-end=\"1448\"\u003e\n\u003cp data-start=\"1389\" data-end=\"1448\"\u003e\u003cstrong data-start=\"1389\" data-end=\"1406\"\u003ePower Supply:\u003c\/strong\u003e External power adapter, 54 VDC \/ 2.22 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1449\" data-end=\"1516\"\u003e\n\u003cp data-start=\"1451\" data-end=\"1475\"\u003e\u003cstrong data-start=\"1451\" data-end=\"1473\"\u003ePower Consumption:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1478\" data-end=\"1516\"\u003e\n\u003cli data-start=\"1478\" data-end=\"1493\"\u003e\n\u003cp data-start=\"1480\" data-end=\"1493\"\u003eIdle: 5.7 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1496\" data-end=\"1516\"\u003e\n\u003cp data-start=\"1498\" data-end=\"1516\"\u003eFull Load: 115 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1518\" data-end=\"1521\"\u003e\n\u003ch2 data-start=\"1523\" data-end=\"1544\"\u003ePoE Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1545\" data-end=\"2096\"\u003e\n\u003cli data-start=\"1545\" data-end=\"1569\"\u003e\n\u003cp data-start=\"1547\" data-end=\"1569\"\u003e\u003cstrong data-start=\"1547\" data-end=\"1563\"\u003ePoE Support:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1570\" data-end=\"1644\"\u003e\n\u003cp data-start=\"1572\" data-end=\"1644\"\u003e\u003cstrong data-start=\"1572\" data-end=\"1590\"\u003ePoE Protocols:\u003c\/strong\u003e IEEE 802.3af \/ IEEE 802.3at \/ Hi-PoE \/ IEEE 802.3bt\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1645\" data-end=\"1772\"\u003e\n\u003cp data-start=\"1647\" data-end=\"1670\"\u003e\u003cstrong data-start=\"1647\" data-end=\"1668\"\u003ePoE Output Power:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1673\" data-end=\"1772\"\u003e\n\u003cli data-start=\"1673\" data-end=\"1703\"\u003e\n\u003cp data-start=\"1675\" data-end=\"1703\"\u003ePorts 1–2: ≤ 90 W per port\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1706\" data-end=\"1736\"\u003e\n\u003cp data-start=\"1708\" data-end=\"1736\"\u003ePorts 3–8: ≤ 30 W per port\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1739\" data-end=\"1772\"\u003e\n\u003cp data-start=\"1741\" data-end=\"1772\"\u003e\u003cstrong data-start=\"1741\" data-end=\"1762\"\u003eTotal PoE Budget:\u003c\/strong\u003e ≤ 110 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1773\" data-end=\"1915\"\u003e\n\u003cp data-start=\"1775\" data-end=\"1802\"\u003e\u003cstrong data-start=\"1775\" data-end=\"1800\"\u003ePoE Power Management:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1805\" data-end=\"1915\"\u003e\n\u003cli data-start=\"1805\" data-end=\"1841\"\u003e\n\u003cp data-start=\"1807\" data-end=\"1841\"\u003ePoE power consumption management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1844\" data-end=\"1864\"\u003e\n\u003cp data-start=\"1846\" data-end=\"1864\"\u003ePoE power on\/off\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1867\" data-end=\"1915\"\u003e\n\u003cp data-start=\"1869\" data-end=\"1915\"\u003eAutomatic PoE shutdown on overload detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1916\" data-end=\"2065\"\u003e\n\u003cp data-start=\"1918\" data-end=\"1943\"\u003e\u003cstrong data-start=\"1918\" data-end=\"1941\"\u003ePoE Pin Assignment:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1946\" data-end=\"2065\"\u003e\n\u003cli data-start=\"1946\" data-end=\"2010\"\u003e\n\u003cp data-start=\"1948\" data-end=\"1964\"\u003e\u003cstrong data-start=\"1948\" data-end=\"1962\"\u003ePorts 1–2:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1969\" data-end=\"2010\"\u003e\n\u003cli data-start=\"1969\" data-end=\"1987\"\u003e\n\u003cp data-start=\"1971\" data-end=\"1987\"\u003eV+: 1, 2, 4, 5\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1992\" data-end=\"2010\"\u003e\n\u003cp data-start=\"1994\" data-end=\"2010\"\u003eV–: 3, 6, 7, 8\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2013\" data-end=\"2065\"\u003e\n\u003cp data-start=\"2015\" data-end=\"2031\"\u003e\u003cstrong data-start=\"2015\" data-end=\"2029\"\u003ePorts 3–8:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2036\" data-end=\"2065\"\u003e\n\u003cli data-start=\"2036\" data-end=\"2048\"\u003e\n\u003cp data-start=\"2038\" data-end=\"2048\"\u003eV+: 1, 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2053\" data-end=\"2065\"\u003e\n\u003cp data-start=\"2055\" data-end=\"2065\"\u003eV–: 3, 6\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2066\" data-end=\"2096\"\u003e\n\u003cp data-start=\"2068\" data-end=\"2096\"\u003e\u003cstrong data-start=\"2068\" data-end=\"2090\"\u003eLong-Distance PoE:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2098\" data-end=\"2101\"\u003e\n\u003ch2 data-start=\"2103\" data-end=\"2123\"\u003eHardware Features\u003c\/h2\u003e\n\u003ch3 data-start=\"2124\" data-end=\"2148\"\u003eDIP Switch Functions\u003c\/h3\u003e\n\u003cul data-start=\"2149\" data-end=\"2563\"\u003e\n\u003cli data-start=\"2149\" data-end=\"2243\"\u003e\n\u003cp data-start=\"2151\" data-end=\"2170\"\u003e\u003cstrong data-start=\"2151\" data-end=\"2168\"\u003eManaged Mode:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2173\" data-end=\"2243\"\u003e\n\u003cli data-start=\"2173\" data-end=\"2219\"\u003e\n\u003cp data-start=\"2175\" data-end=\"2219\"\u003eON (default): Local web + cloud management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2222\" data-end=\"2243\"\u003e\n\u003cp data-start=\"2224\" data-end=\"2243\"\u003eOFF: Unmanaged mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2244\" data-end=\"2406\"\u003e\n\u003cp data-start=\"2246\" data-end=\"2265\"\u003e\u003cstrong data-start=\"2246\" data-end=\"2263\"\u003ePoE Watchdog:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2268\" data-end=\"2406\"\u003e\n\u003cli data-start=\"2268\" data-end=\"2290\"\u003e\n\u003cp data-start=\"2270\" data-end=\"2290\"\u003eMonitors ports 1–8\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2293\" data-end=\"2363\"\u003e\n\u003cp data-start=\"2295\" data-end=\"2363\"\u003eAutomatically restarts PoE if no traffic is detected for 2 minutes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2366\" data-end=\"2406\"\u003e\n\u003cp data-start=\"2368\" data-end=\"2406\"\u003e\u003cem data-start=\"2368\" data-end=\"2406\"\u003eOnly active when Managed Mode is OFF\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2407\" data-end=\"2538\"\u003e\n\u003cp data-start=\"2409\" data-end=\"2427\"\u003e\u003cstrong data-start=\"2409\" data-end=\"2425\"\u003eExtend Mode:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2430\" data-end=\"2538\"\u003e\n\u003cli data-start=\"2430\" data-end=\"2495\"\u003e\n\u003cp data-start=\"2432\" data-end=\"2495\"\u003ePorts 1–8 support up to \u003cstrong data-start=\"2456\" data-end=\"2465\"\u003e250 m\u003c\/strong\u003e transmission at \u003cstrong data-start=\"2482\" data-end=\"2493\"\u003e10 Mbps\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2498\" data-end=\"2538\"\u003e\n\u003cp data-start=\"2500\" data-end=\"2538\"\u003e\u003cem data-start=\"2500\" data-end=\"2538\"\u003eOnly active when Managed Mode is OFF\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2540\" data-end=\"2563\"\u003e\n\u003cp data-start=\"2542\" data-end=\"2563\"\u003e\u003cstrong data-start=\"2542\" data-end=\"2559\"\u003eReset Button:\u003c\/strong\u003e 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2565\" data-end=\"2568\"\u003e\n\u003ch2 data-start=\"2570\" data-end=\"2584\"\u003ePerformance\u003c\/h2\u003e\n\u003cul data-start=\"2585\" data-end=\"2736\"\u003e\n\u003cli data-start=\"2585\" data-end=\"2614\"\u003e\n\u003cp data-start=\"2587\" data-end=\"2614\"\u003e\u003cstrong data-start=\"2587\" data-end=\"2596\"\u003eMTBF:\u003c\/strong\u003e 2,482,955 hours\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2615\" data-end=\"2644\"\u003e\n\u003cp data-start=\"2617\" data-end=\"2644\"\u003e\u003cstrong data-start=\"2617\" data-end=\"2635\"\u003ePacket Buffer:\u003c\/strong\u003e 4 Mbit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2645\" data-end=\"2678\"\u003e\n\u003cp data-start=\"2647\" data-end=\"2678\"\u003e\u003cstrong data-start=\"2647\" data-end=\"2663\"\u003eJumbo Frame:\u003c\/strong\u003e 15,360 Bytes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2679\" data-end=\"2708\"\u003e\n\u003cp data-start=\"2681\" data-end=\"2708\"\u003e\u003cstrong data-start=\"2681\" data-end=\"2703\"\u003eMAC Address Table:\u003c\/strong\u003e 8K\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2709\" data-end=\"2736\"\u003e\n\u003cp data-start=\"2711\" data-end=\"2736\"\u003e\u003cstrong data-start=\"2711\" data-end=\"2731\"\u003eSupported VLANs:\u003c\/strong\u003e 32\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2738\" data-end=\"2741\"\u003e\n\u003ch2 data-start=\"2743\" data-end=\"2763\"\u003eNetwork Standards\u003c\/h2\u003e\n\u003cul data-start=\"2764\" data-end=\"2897\"\u003e\n\u003cli data-start=\"2764\" data-end=\"2897\"\u003e\n\u003cp data-start=\"2766\" data-end=\"2787\"\u003e\u003cstrong data-start=\"2766\" data-end=\"2785\"\u003eIEEE Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2790\" data-end=\"2897\"\u003e\n\u003cli data-start=\"2790\" data-end=\"2804\"\u003e\n\u003cp data-start=\"2792\" data-end=\"2804\"\u003eIEEE 802.3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2807\" data-end=\"2822\"\u003e\n\u003cp data-start=\"2809\" data-end=\"2822\"\u003eIEEE 802.3u\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2825\" data-end=\"2840\"\u003e\n\u003cp data-start=\"2827\" data-end=\"2840\"\u003eIEEE 802.3x\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2843\" data-end=\"2859\"\u003e\n\u003cp data-start=\"2845\" data-end=\"2859\"\u003eIEEE 802.3ab\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2862\" data-end=\"2878\"\u003e\n\u003cp data-start=\"2864\" data-end=\"2878\"\u003eIEEE 802.3az\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2881\" data-end=\"2897\"\u003e\n\u003cp data-start=\"2883\" data-end=\"2897\"\u003eIEEE 802.3ad\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2899\" data-end=\"2902\"\u003e\n\u003ch2 data-start=\"2904\" data-end=\"2923\"\u003eNetwork Features\u003c\/h2\u003e\n\u003cul data-start=\"2924\" data-end=\"3394\"\u003e\n\u003cli data-start=\"2924\" data-end=\"2967\"\u003e\n\u003cp data-start=\"2926\" data-end=\"2967\"\u003e\u003cstrong data-start=\"2926\" data-end=\"2955\"\u003eEthernet Loop Protection:\u003c\/strong\u003e STP, RSTP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2968\" data-end=\"2998\"\u003e\n\u003cp data-start=\"2970\" data-end=\"2998\"\u003e\u003cstrong data-start=\"2970\" data-end=\"2979\"\u003eVLAN:\u003c\/strong\u003e IEEE 802.1Q VLAN\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2999\" data-end=\"3043\"\u003e\n\u003cp data-start=\"3001\" data-end=\"3043\"\u003e\u003cstrong data-start=\"3001\" data-end=\"3022\"\u003eLink Aggregation:\u003c\/strong\u003e Static aggregation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3044\" data-end=\"3238\"\u003e\n\u003cp data-start=\"3046\" data-end=\"3066\"\u003e\u003cstrong data-start=\"3046\" data-end=\"3064\"\u003ePort Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3069\" data-end=\"3238\"\u003e\n\u003cli data-start=\"3069\" data-end=\"3097\"\u003e\n\u003cp data-start=\"3071\" data-end=\"3097\"\u003eIEEE 802.3x Flow Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3100\" data-end=\"3131\"\u003e\n\u003cp data-start=\"3102\" data-end=\"3131\"\u003eUnknown Unicast Suppression\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3134\" data-end=\"3161\"\u003e\n\u003cp data-start=\"3136\" data-end=\"3161\"\u003eMulticast Storm Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3164\" data-end=\"3191\"\u003e\n\u003cp data-start=\"3166\" data-end=\"3191\"\u003eBroadcast Storm Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3194\" data-end=\"3216\"\u003e\n\u003cp data-start=\"3196\" data-end=\"3216\"\u003eMAC + Port Binding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3219\" data-end=\"3238\"\u003e\n\u003cp data-start=\"3221\" data-end=\"3238\"\u003eLoop Prevention\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3239\" data-end=\"3309\"\u003e\n\u003cp data-start=\"3241\" data-end=\"3262\"\u003e\u003cstrong data-start=\"3241\" data-end=\"3260\"\u003ePort Mirroring:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3265\" data-end=\"3309\"\u003e\n\u003cli data-start=\"3265\" data-end=\"3289\"\u003e\n\u003cp data-start=\"3267\" data-end=\"3289\"\u003eLocal Port Mirroring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3292\" data-end=\"3309\"\u003e\n\u003cp data-start=\"3294\" data-end=\"3309\"\u003eN:1 Mirroring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3310\" data-end=\"3335\"\u003e\n\u003cp data-start=\"3312\" data-end=\"3335\"\u003e\u003cstrong data-start=\"3312\" data-end=\"3329\"\u003eLLDP Support:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3336\" data-end=\"3361\"\u003e\n\u003cp data-start=\"3338\" data-end=\"3361\"\u003e\u003cstrong data-start=\"3338\" data-end=\"3347\"\u003eDHCP:\u003c\/strong\u003e DHCP Client\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3362\" data-end=\"3394\"\u003e\n\u003cp data-start=\"3364\" data-end=\"3394\"\u003e\u003cstrong data-start=\"3364\" data-end=\"3377\"\u003eSecurity:\u003c\/strong\u003e Port Isolation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3396\" data-end=\"3399\"\u003e\n\u003ch2 data-start=\"3401\" data-end=\"3414\"\u003eManagement\u003c\/h2\u003e\n\u003cul data-start=\"3415\" data-end=\"3550\"\u003e\n\u003cli data-start=\"3415\" data-end=\"3486\"\u003e\n\u003cp data-start=\"3417\" data-end=\"3442\"\u003e\u003cstrong data-start=\"3417\" data-end=\"3440\"\u003eManagement Methods:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3445\" data-end=\"3486\"\u003e\n\u003cli data-start=\"3445\" data-end=\"3463\"\u003e\n\u003cp data-start=\"3447\" data-end=\"3463\"\u003eWeb Management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3466\" data-end=\"3486\"\u003e\n\u003cp data-start=\"3468\" data-end=\"3486\"\u003eCloud Management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3487\" data-end=\"3550\"\u003e\n\u003cp data-start=\"3489\" data-end=\"3520\"\u003e\u003cstrong data-start=\"3489\" data-end=\"3518\"\u003eMonitoring \u0026amp; Maintenance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3523\" data-end=\"3550\"\u003e\n\u003cli data-start=\"3523\" data-end=\"3531\"\u003e\n\u003cp data-start=\"3525\" data-end=\"3531\"\u003eLogs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3534\" data-end=\"3550\"\u003e\n\u003cp data-start=\"3536\" data-end=\"3550\"\u003eFault Alarms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3552\" data-end=\"3555\"\u003e\n\u003ch2 data-start=\"3557\" data-end=\"3570\"\u003eProtection\u003c\/h2\u003e\n\u003cul data-start=\"3571\" data-end=\"3734\"\u003e\n\u003cli data-start=\"3571\" data-end=\"3650\"\u003e\n\u003cp data-start=\"3573\" data-end=\"3594\"\u003e\u003cstrong data-start=\"3573\" data-end=\"3592\"\u003eESD Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3597\" data-end=\"3650\"\u003e\n\u003cli data-start=\"3597\" data-end=\"3620\"\u003e\n\u003cp data-start=\"3599\" data-end=\"3620\"\u003eAir Discharge: 8 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3623\" data-end=\"3650\"\u003e\n\u003cp data-start=\"3625\" data-end=\"3650\"\u003eContact Discharge: 6 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3651\" data-end=\"3734\"\u003e\n\u003cp data-start=\"3653\" data-end=\"3680\"\u003e\u003cstrong data-start=\"3653\" data-end=\"3678\"\u003eLightning Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3683\" data-end=\"3734\"\u003e\n\u003cli data-start=\"3683\" data-end=\"3704\"\u003e\n\u003cp data-start=\"3685\" data-end=\"3704\"\u003eCommon Mode: 6 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3707\" data-end=\"3734\"\u003e\n\u003cp data-start=\"3709\" data-end=\"3734\"\u003eDifferential Mode: 1 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3736\" data-end=\"3739\"\u003e\n\u003ch2 data-start=\"3741\" data-end=\"3767\"\u003ePhysical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"3768\" data-end=\"4041\"\u003e\n\u003cli data-start=\"3768\" data-end=\"3805\"\u003e\n\u003cp data-start=\"3770\" data-end=\"3805\"\u003e\u003cstrong data-start=\"3770\" data-end=\"3785\"\u003eNet Weight:\u003c\/strong\u003e 0.36 kg (0.79 lb)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3806\" data-end=\"3845\"\u003e\n\u003cp data-start=\"3808\" data-end=\"3845\"\u003e\u003cstrong data-start=\"3808\" data-end=\"3825\"\u003eGross Weight:\u003c\/strong\u003e 1.13 kg (2.49 lb)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3846\" data-end=\"3925\"\u003e\n\u003cp data-start=\"3848\" data-end=\"3873\"\u003e\u003cstrong data-start=\"3848\" data-end=\"3871\"\u003eProduct Dimensions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3876\" data-end=\"3925\"\u003e\n\u003cli data-start=\"3876\" data-end=\"3925\"\u003e\n\u003cp data-start=\"3878\" data-end=\"3925\"\u003e184.6 × 103.3 × 27 mm (7.27\" × 4.07\" × 1.06\")\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3926\" data-end=\"4004\"\u003e\n\u003cp data-start=\"3928\" data-end=\"3955\"\u003e\u003cstrong data-start=\"3928\" data-end=\"3953\"\u003ePackaging Dimensions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3958\" data-end=\"4004\"\u003e\n\u003cli data-start=\"3958\" data-end=\"4004\"\u003e\n\u003cp data-start=\"3960\" data-end=\"4004\"\u003e252 × 137 × 113 mm (9.92\" × 5.39\" × 4.45\")\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4005\" data-end=\"4041\"\u003e\n\u003cp data-start=\"4007\" data-end=\"4041\"\u003e\u003cstrong data-start=\"4007\" data-end=\"4027\"\u003eCasing Material:\u003c\/strong\u003e Sheet metal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4043\" data-end=\"4046\"\u003e\n\u003ch2 data-start=\"4048\" data-end=\"4063\"\u003eInstallation\u003c\/h2\u003e\n\u003cul data-start=\"4064\" data-end=\"4115\"\u003e\n\u003cli data-start=\"4064\" data-end=\"4115\"\u003e\n\u003cp data-start=\"4066\" data-end=\"4115\"\u003e\u003cstrong data-start=\"4066\" data-end=\"4087\"\u003eMounting Options:\u003c\/strong\u003e Desktop mount, Wall mount\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4117\" data-end=\"4120\"\u003e\n\u003ch2 data-start=\"4122\" data-end=\"4139\"\u003eCertifications\u003c\/h2\u003e\n\u003cul data-start=\"4140\" data-end=\"4148\"\u003e\n\u003cli data-start=\"4140\" data-end=\"4148\"\u003e\n\u003cp data-start=\"4142\" data-end=\"4148\"\u003e\u003cstrong data-start=\"4142\" data-end=\"4148\"\u003eCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4150\" data-end=\"4153\"\u003e\n\u003ch2 data-start=\"4155\" data-end=\"4170\"\u003ePacking List\u003c\/h2\u003e\n\u003cul data-start=\"4171\" data-end=\"4272\"\u003e\n\u003cli data-start=\"4171\" data-end=\"4190\"\u003e\n\u003cp data-start=\"4173\" data-end=\"4190\"\u003e1 × User Manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4191\" data-end=\"4231\"\u003e\n\u003cp data-start=\"4193\" data-end=\"4231\"\u003e1 × Legal and Regulatory Information\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4232\" data-end=\"4253\"\u003e\n\u003cp data-start=\"4234\" data-end=\"4253\"\u003e1 × Power Adapter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4254\" data-end=\"4272\"\u003e\n\u003cp data-start=\"4256\" data-end=\"4272\"\u003e1 × Power Cord\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 3 Year Dahua ANZ Manufacturer Warranty\u003c\/p\u003e"}
Translation missing: en.products.product.regular_price $149.00 -
-
{"id":8191822069849,"title":"Dahua CS4010-8GT-110 10-Port Cloud Managed Desktop Gigabit Switch with 8-Port POE","handle":"cs4010-8gt-110-dahua-10-port-cloud-managed-desktop-gigabit-switch-with-8-port-poe","description":"\u003ch2 data-start=\"153\" data-end=\"220\"\u003e10-Port Cloud Managed Desktop \u003cstrong data-start=\"186\" data-end=\"197\"\u003eGigabit\u003c\/strong\u003e Switch with 8-Port PoE\u003c\/h2\u003e\n\u003ch3 data-start=\"222\" data-end=\"238\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"239\" data-end=\"804\"\u003e\n\u003cli data-start=\"239\" data-end=\"308\"\u003e\n\u003cp data-start=\"241\" data-end=\"308\"\u003e\u003cstrong data-start=\"241\" data-end=\"272\"\u003e8 × RJ-45 Gigabit PoE ports\u003c\/strong\u003e, \u003cstrong data-start=\"274\" data-end=\"308\"\u003e2 × RJ-45 Gigabit uplink ports\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"309\" data-end=\"432\"\u003e\n\u003cp data-start=\"311\" data-end=\"339\"\u003e\u003cstrong data-start=\"311\" data-end=\"337\"\u003e110 W total PoE budget\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"342\" data-end=\"432\"\u003e\n\u003cli data-start=\"342\" data-end=\"378\"\u003e\n\u003cp data-start=\"344\" data-end=\"378\"\u003eIEEE 802.3af\/at on all PoE ports\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"381\" data-end=\"432\"\u003e\n\u003cp data-start=\"383\" data-end=\"432\"\u003e\u003cstrong data-start=\"383\" data-end=\"432\"\u003eIEEE 802.3bt support on Ports 1–2 (red ports)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"433\" data-end=\"552\"\u003e\n\u003cp data-start=\"435\" data-end=\"474\"\u003e\u003cstrong data-start=\"435\" data-end=\"449\"\u003eDIP switch\u003c\/strong\u003e for fast mode switching:\u003c\/p\u003e\n\u003cul data-start=\"477\" data-end=\"552\"\u003e\n\u003cli data-start=\"477\" data-end=\"511\"\u003e\n\u003cp data-start=\"479\" data-end=\"511\"\u003eCloud-Managed \/ Unmanaged Mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"514\" data-end=\"530\"\u003e\n\u003cp data-start=\"516\" data-end=\"530\"\u003ePoE Watchdog\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"533\" data-end=\"552\"\u003e\n\u003cp data-start=\"535\" data-end=\"552\"\u003eLong-Distance PoE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"553\" data-end=\"603\"\u003e\n\u003cp data-start=\"555\" data-end=\"603\"\u003e\u003cstrong data-start=\"555\" data-end=\"586\"\u003eWide operating temperature:\u003c\/strong\u003e –10 °C to +55 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"604\" data-end=\"660\"\u003e\n\u003cp data-start=\"606\" data-end=\"660\"\u003eSupports \u003cstrong data-start=\"615\" data-end=\"634\"\u003eVLAN, STP, RSTP\u003c\/strong\u003e, and \u003cstrong data-start=\"640\" data-end=\"660\"\u003elink aggregation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"661\" data-end=\"734\"\u003e\n\u003cp data-start=\"663\" data-end=\"734\"\u003e\u003cstrong data-start=\"663\" data-end=\"678\"\u003eWeb-managed\u003c\/strong\u003e and \u003cstrong data-start=\"683\" data-end=\"715\"\u003ecentralised cloud management\u003c\/strong\u003e via \u003cstrong data-start=\"720\" data-end=\"734\"\u003eDoLynk App\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"735\" data-end=\"804\"\u003e\n\u003cp data-start=\"737\" data-end=\"804\"\u003eEasy configuration with \u003cstrong data-start=\"761\" data-end=\"804\"\u003eauto network detection and system setup\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"735\" data-end=\"804\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0047\/9510\/5391\/files\/DH-CS4010-8GT-110_V2_datasheet_20251104.pdf?v=1765923577\"\u003e\u003cstrong data-start=\"761\" data-end=\"804\"\u003eDatasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"806\" data-end=\"809\"\u003e\n\u003ch2 data-start=\"811\" data-end=\"834\"\u003eBasic Specifications\u003c\/h2\u003e\n\u003cul data-start=\"835\" data-end=\"946\"\u003e\n\u003cli data-start=\"835\" data-end=\"867\"\u003e\n\u003cp data-start=\"837\" data-end=\"867\"\u003e\u003cstrong data-start=\"837\" data-end=\"857\"\u003eSwitching Layer:\u003c\/strong\u003e Layer 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"868\" data-end=\"903\"\u003e\n\u003cp data-start=\"870\" data-end=\"903\"\u003e\u003cstrong data-start=\"870\" data-end=\"893\"\u003eSwitching Capacity:\u003c\/strong\u003e 20 Gbps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"904\" data-end=\"946\"\u003e\n\u003cp data-start=\"906\" data-end=\"946\"\u003e\u003cstrong data-start=\"906\" data-end=\"933\"\u003ePacket Forwarding Rate:\u003c\/strong\u003e 14.88 Mpps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"948\" data-end=\"951\"\u003e\n\u003ch2 data-start=\"953\" data-end=\"974\"\u003ePort Configuration\u003c\/h2\u003e\n\u003cul data-start=\"975\" data-end=\"1090\"\u003e\n\u003cli data-start=\"975\" data-end=\"1026\"\u003e\n\u003cp data-start=\"977\" data-end=\"1026\"\u003e\u003cstrong data-start=\"977\" data-end=\"991\"\u003ePorts 1–8:\u003c\/strong\u003e 8 × RJ-45 10\/100\/1000 Mbps (PoE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1027\" data-end=\"1090\"\u003e\n\u003cp data-start=\"1029\" data-end=\"1090\"\u003e\u003cstrong data-start=\"1029\" data-end=\"1044\"\u003ePorts 9–10:\u003c\/strong\u003e 2 × RJ-45 10\/100\/1000 Mbps (Gigabit uplink)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1092\" data-end=\"1095\"\u003e\n\u003ch2 data-start=\"1097\" data-end=\"1128\"\u003eEnvironmental Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1129\" data-end=\"1371\"\u003e\n\u003cli data-start=\"1129\" data-end=\"1196\"\u003e\n\u003cp data-start=\"1131\" data-end=\"1196\"\u003e\u003cstrong data-start=\"1131\" data-end=\"1157\"\u003eOperating Temperature:\u003c\/strong\u003e –10 °C to +55 °C (+14 °F to +131 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1197\" data-end=\"1252\"\u003e\n\u003cp data-start=\"1199\" data-end=\"1252\"\u003e\u003cstrong data-start=\"1199\" data-end=\"1222\"\u003eOperating Humidity:\u003c\/strong\u003e 10%–90% RH (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1253\" data-end=\"1318\"\u003e\n\u003cp data-start=\"1255\" data-end=\"1318\"\u003e\u003cstrong data-start=\"1255\" data-end=\"1279\"\u003eStorage Temperature:\u003c\/strong\u003e –40 °C to +75 °C (–40 °F to +167 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1319\" data-end=\"1371\"\u003e\n\u003cp data-start=\"1321\" data-end=\"1371\"\u003e\u003cstrong data-start=\"1321\" data-end=\"1342\"\u003eStorage Humidity:\u003c\/strong\u003e 5%–95% RH (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1373\" data-end=\"1376\"\u003e\n\u003ch2 data-start=\"1378\" data-end=\"1386\"\u003ePower\u003c\/h2\u003e\n\u003cul data-start=\"1387\" data-end=\"1516\"\u003e\n\u003cli data-start=\"1387\" data-end=\"1448\"\u003e\n\u003cp data-start=\"1389\" data-end=\"1448\"\u003e\u003cstrong data-start=\"1389\" data-end=\"1406\"\u003ePower Supply:\u003c\/strong\u003e External power adapter, 54 VDC \/ 2.22 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1449\" data-end=\"1516\"\u003e\n\u003cp data-start=\"1451\" data-end=\"1475\"\u003e\u003cstrong data-start=\"1451\" data-end=\"1473\"\u003ePower Consumption:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1478\" data-end=\"1516\"\u003e\n\u003cli data-start=\"1478\" data-end=\"1493\"\u003e\n\u003cp data-start=\"1480\" data-end=\"1493\"\u003eIdle: 5.7 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1496\" data-end=\"1516\"\u003e\n\u003cp data-start=\"1498\" data-end=\"1516\"\u003eFull Load: 115 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1518\" data-end=\"1521\"\u003e\n\u003ch2 data-start=\"1523\" data-end=\"1544\"\u003ePoE Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1545\" data-end=\"2096\"\u003e\n\u003cli data-start=\"1545\" data-end=\"1569\"\u003e\n\u003cp data-start=\"1547\" data-end=\"1569\"\u003e\u003cstrong data-start=\"1547\" data-end=\"1563\"\u003ePoE Support:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1570\" data-end=\"1644\"\u003e\n\u003cp data-start=\"1572\" data-end=\"1644\"\u003e\u003cstrong data-start=\"1572\" data-end=\"1590\"\u003ePoE Protocols:\u003c\/strong\u003e IEEE 802.3af \/ IEEE 802.3at \/ Hi-PoE \/ IEEE 802.3bt\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1645\" data-end=\"1772\"\u003e\n\u003cp data-start=\"1647\" data-end=\"1670\"\u003e\u003cstrong data-start=\"1647\" data-end=\"1668\"\u003ePoE Output Power:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1673\" data-end=\"1772\"\u003e\n\u003cli data-start=\"1673\" data-end=\"1703\"\u003e\n\u003cp data-start=\"1675\" data-end=\"1703\"\u003ePorts 1–2: ≤ 90 W per port\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1706\" data-end=\"1736\"\u003e\n\u003cp data-start=\"1708\" data-end=\"1736\"\u003ePorts 3–8: ≤ 30 W per port\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1739\" data-end=\"1772\"\u003e\n\u003cp data-start=\"1741\" data-end=\"1772\"\u003e\u003cstrong data-start=\"1741\" data-end=\"1762\"\u003eTotal PoE Budget:\u003c\/strong\u003e ≤ 110 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1773\" data-end=\"1915\"\u003e\n\u003cp data-start=\"1775\" data-end=\"1802\"\u003e\u003cstrong data-start=\"1775\" data-end=\"1800\"\u003ePoE Power Management:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1805\" data-end=\"1915\"\u003e\n\u003cli data-start=\"1805\" data-end=\"1841\"\u003e\n\u003cp data-start=\"1807\" data-end=\"1841\"\u003ePoE power consumption management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1844\" data-end=\"1864\"\u003e\n\u003cp data-start=\"1846\" data-end=\"1864\"\u003ePoE power on\/off\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1867\" data-end=\"1915\"\u003e\n\u003cp data-start=\"1869\" data-end=\"1915\"\u003eAutomatic PoE shutdown on overload detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1916\" data-end=\"2065\"\u003e\n\u003cp data-start=\"1918\" data-end=\"1943\"\u003e\u003cstrong data-start=\"1918\" data-end=\"1941\"\u003ePoE Pin Assignment:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1946\" data-end=\"2065\"\u003e\n\u003cli data-start=\"1946\" data-end=\"2010\"\u003e\n\u003cp data-start=\"1948\" data-end=\"1964\"\u003e\u003cstrong data-start=\"1948\" data-end=\"1962\"\u003ePorts 1–2:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1969\" data-end=\"2010\"\u003e\n\u003cli data-start=\"1969\" data-end=\"1987\"\u003e\n\u003cp data-start=\"1971\" data-end=\"1987\"\u003eV+: 1, 2, 4, 5\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1992\" data-end=\"2010\"\u003e\n\u003cp data-start=\"1994\" data-end=\"2010\"\u003eV–: 3, 6, 7, 8\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2013\" data-end=\"2065\"\u003e\n\u003cp data-start=\"2015\" data-end=\"2031\"\u003e\u003cstrong data-start=\"2015\" data-end=\"2029\"\u003ePorts 3–8:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2036\" data-end=\"2065\"\u003e\n\u003cli data-start=\"2036\" data-end=\"2048\"\u003e\n\u003cp data-start=\"2038\" data-end=\"2048\"\u003eV+: 1, 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2053\" data-end=\"2065\"\u003e\n\u003cp data-start=\"2055\" data-end=\"2065\"\u003eV–: 3, 6\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2066\" data-end=\"2096\"\u003e\n\u003cp data-start=\"2068\" data-end=\"2096\"\u003e\u003cstrong data-start=\"2068\" data-end=\"2090\"\u003eLong-Distance PoE:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2098\" data-end=\"2101\"\u003e\n\u003ch2 data-start=\"2103\" data-end=\"2123\"\u003eHardware Features\u003c\/h2\u003e\n\u003ch3 data-start=\"2124\" data-end=\"2148\"\u003eDIP Switch Functions\u003c\/h3\u003e\n\u003cul data-start=\"2149\" data-end=\"2563\"\u003e\n\u003cli data-start=\"2149\" data-end=\"2243\"\u003e\n\u003cp data-start=\"2151\" data-end=\"2170\"\u003e\u003cstrong data-start=\"2151\" data-end=\"2168\"\u003eManaged Mode:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2173\" data-end=\"2243\"\u003e\n\u003cli data-start=\"2173\" data-end=\"2219\"\u003e\n\u003cp data-start=\"2175\" data-end=\"2219\"\u003eON (default): Local web + cloud management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2222\" data-end=\"2243\"\u003e\n\u003cp data-start=\"2224\" data-end=\"2243\"\u003eOFF: Unmanaged mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2244\" data-end=\"2406\"\u003e\n\u003cp data-start=\"2246\" data-end=\"2265\"\u003e\u003cstrong data-start=\"2246\" data-end=\"2263\"\u003ePoE Watchdog:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2268\" data-end=\"2406\"\u003e\n\u003cli data-start=\"2268\" data-end=\"2290\"\u003e\n\u003cp data-start=\"2270\" data-end=\"2290\"\u003eMonitors ports 1–8\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2293\" data-end=\"2363\"\u003e\n\u003cp data-start=\"2295\" data-end=\"2363\"\u003eAutomatically restarts PoE if no traffic is detected for 2 minutes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2366\" data-end=\"2406\"\u003e\n\u003cp data-start=\"2368\" data-end=\"2406\"\u003e\u003cem data-start=\"2368\" data-end=\"2406\"\u003eOnly active when Managed Mode is OFF\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2407\" data-end=\"2538\"\u003e\n\u003cp data-start=\"2409\" data-end=\"2427\"\u003e\u003cstrong data-start=\"2409\" data-end=\"2425\"\u003eExtend Mode:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2430\" data-end=\"2538\"\u003e\n\u003cli data-start=\"2430\" data-end=\"2495\"\u003e\n\u003cp data-start=\"2432\" data-end=\"2495\"\u003ePorts 1–8 support up to \u003cstrong data-start=\"2456\" data-end=\"2465\"\u003e250 m\u003c\/strong\u003e transmission at \u003cstrong data-start=\"2482\" data-end=\"2493\"\u003e10 Mbps\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2498\" data-end=\"2538\"\u003e\n\u003cp data-start=\"2500\" data-end=\"2538\"\u003e\u003cem data-start=\"2500\" data-end=\"2538\"\u003eOnly active when Managed Mode is OFF\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2540\" data-end=\"2563\"\u003e\n\u003cp data-start=\"2542\" data-end=\"2563\"\u003e\u003cstrong data-start=\"2542\" data-end=\"2559\"\u003eReset Button:\u003c\/strong\u003e 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2565\" data-end=\"2568\"\u003e\n\u003ch2 data-start=\"2570\" data-end=\"2584\"\u003ePerformance\u003c\/h2\u003e\n\u003cul data-start=\"2585\" data-end=\"2736\"\u003e\n\u003cli data-start=\"2585\" data-end=\"2614\"\u003e\n\u003cp data-start=\"2587\" data-end=\"2614\"\u003e\u003cstrong data-start=\"2587\" data-end=\"2596\"\u003eMTBF:\u003c\/strong\u003e 2,482,955 hours\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2615\" data-end=\"2644\"\u003e\n\u003cp data-start=\"2617\" data-end=\"2644\"\u003e\u003cstrong data-start=\"2617\" data-end=\"2635\"\u003ePacket Buffer:\u003c\/strong\u003e 4 Mbit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2645\" data-end=\"2678\"\u003e\n\u003cp data-start=\"2647\" data-end=\"2678\"\u003e\u003cstrong data-start=\"2647\" data-end=\"2663\"\u003eJumbo Frame:\u003c\/strong\u003e 15,360 Bytes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2679\" data-end=\"2708\"\u003e\n\u003cp data-start=\"2681\" data-end=\"2708\"\u003e\u003cstrong data-start=\"2681\" data-end=\"2703\"\u003eMAC Address Table:\u003c\/strong\u003e 8K\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2709\" data-end=\"2736\"\u003e\n\u003cp data-start=\"2711\" data-end=\"2736\"\u003e\u003cstrong data-start=\"2711\" data-end=\"2731\"\u003eSupported VLANs:\u003c\/strong\u003e 32\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2738\" data-end=\"2741\"\u003e\n\u003ch2 data-start=\"2743\" data-end=\"2763\"\u003eNetwork Standards\u003c\/h2\u003e\n\u003cul data-start=\"2764\" data-end=\"2897\"\u003e\n\u003cli data-start=\"2764\" data-end=\"2897\"\u003e\n\u003cp data-start=\"2766\" data-end=\"2787\"\u003e\u003cstrong data-start=\"2766\" data-end=\"2785\"\u003eIEEE Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2790\" data-end=\"2897\"\u003e\n\u003cli data-start=\"2790\" data-end=\"2804\"\u003e\n\u003cp data-start=\"2792\" data-end=\"2804\"\u003eIEEE 802.3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2807\" data-end=\"2822\"\u003e\n\u003cp data-start=\"2809\" data-end=\"2822\"\u003eIEEE 802.3u\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2825\" data-end=\"2840\"\u003e\n\u003cp data-start=\"2827\" data-end=\"2840\"\u003eIEEE 802.3x\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2843\" data-end=\"2859\"\u003e\n\u003cp data-start=\"2845\" data-end=\"2859\"\u003eIEEE 802.3ab\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2862\" data-end=\"2878\"\u003e\n\u003cp data-start=\"2864\" data-end=\"2878\"\u003eIEEE 802.3az\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2881\" data-end=\"2897\"\u003e\n\u003cp data-start=\"2883\" data-end=\"2897\"\u003eIEEE 802.3ad\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2899\" data-end=\"2902\"\u003e\n\u003ch2 data-start=\"2904\" data-end=\"2923\"\u003eNetwork Features\u003c\/h2\u003e\n\u003cul data-start=\"2924\" data-end=\"3394\"\u003e\n\u003cli data-start=\"2924\" data-end=\"2967\"\u003e\n\u003cp data-start=\"2926\" data-end=\"2967\"\u003e\u003cstrong data-start=\"2926\" data-end=\"2955\"\u003eEthernet Loop Protection:\u003c\/strong\u003e STP, RSTP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2968\" data-end=\"2998\"\u003e\n\u003cp data-start=\"2970\" data-end=\"2998\"\u003e\u003cstrong data-start=\"2970\" data-end=\"2979\"\u003eVLAN:\u003c\/strong\u003e IEEE 802.1Q VLAN\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2999\" data-end=\"3043\"\u003e\n\u003cp data-start=\"3001\" data-end=\"3043\"\u003e\u003cstrong data-start=\"3001\" data-end=\"3022\"\u003eLink Aggregation:\u003c\/strong\u003e Static aggregation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3044\" data-end=\"3238\"\u003e\n\u003cp data-start=\"3046\" data-end=\"3066\"\u003e\u003cstrong data-start=\"3046\" data-end=\"3064\"\u003ePort Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3069\" data-end=\"3238\"\u003e\n\u003cli data-start=\"3069\" data-end=\"3097\"\u003e\n\u003cp data-start=\"3071\" data-end=\"3097\"\u003eIEEE 802.3x Flow Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3100\" data-end=\"3131\"\u003e\n\u003cp data-start=\"3102\" data-end=\"3131\"\u003eUnknown Unicast Suppression\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3134\" data-end=\"3161\"\u003e\n\u003cp data-start=\"3136\" data-end=\"3161\"\u003eMulticast Storm Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3164\" data-end=\"3191\"\u003e\n\u003cp data-start=\"3166\" data-end=\"3191\"\u003eBroadcast Storm Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3194\" data-end=\"3216\"\u003e\n\u003cp data-start=\"3196\" data-end=\"3216\"\u003eMAC + Port Binding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3219\" data-end=\"3238\"\u003e\n\u003cp data-start=\"3221\" data-end=\"3238\"\u003eLoop Prevention\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3239\" data-end=\"3309\"\u003e\n\u003cp data-start=\"3241\" data-end=\"3262\"\u003e\u003cstrong data-start=\"3241\" data-end=\"3260\"\u003ePort Mirroring:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3265\" data-end=\"3309\"\u003e\n\u003cli data-start=\"3265\" data-end=\"3289\"\u003e\n\u003cp data-start=\"3267\" data-end=\"3289\"\u003eLocal Port Mirroring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3292\" data-end=\"3309\"\u003e\n\u003cp data-start=\"3294\" data-end=\"3309\"\u003eN:1 Mirroring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3310\" data-end=\"3335\"\u003e\n\u003cp data-start=\"3312\" data-end=\"3335\"\u003e\u003cstrong data-start=\"3312\" data-end=\"3329\"\u003eLLDP Support:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3336\" data-end=\"3361\"\u003e\n\u003cp data-start=\"3338\" data-end=\"3361\"\u003e\u003cstrong data-start=\"3338\" data-end=\"3347\"\u003eDHCP:\u003c\/strong\u003e DHCP Client\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3362\" data-end=\"3394\"\u003e\n\u003cp data-start=\"3364\" data-end=\"3394\"\u003e\u003cstrong data-start=\"3364\" data-end=\"3377\"\u003eSecurity:\u003c\/strong\u003e Port Isolation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3396\" data-end=\"3399\"\u003e\n\u003ch2 data-start=\"3401\" data-end=\"3414\"\u003eManagement\u003c\/h2\u003e\n\u003cul data-start=\"3415\" data-end=\"3550\"\u003e\n\u003cli data-start=\"3415\" data-end=\"3486\"\u003e\n\u003cp data-start=\"3417\" data-end=\"3442\"\u003e\u003cstrong data-start=\"3417\" data-end=\"3440\"\u003eManagement Methods:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3445\" data-end=\"3486\"\u003e\n\u003cli data-start=\"3445\" data-end=\"3463\"\u003e\n\u003cp data-start=\"3447\" data-end=\"3463\"\u003eWeb Management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3466\" data-end=\"3486\"\u003e\n\u003cp data-start=\"3468\" data-end=\"3486\"\u003eCloud Management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3487\" data-end=\"3550\"\u003e\n\u003cp data-start=\"3489\" data-end=\"3520\"\u003e\u003cstrong data-start=\"3489\" data-end=\"3518\"\u003eMonitoring \u0026amp; Maintenance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3523\" data-end=\"3550\"\u003e\n\u003cli data-start=\"3523\" data-end=\"3531\"\u003e\n\u003cp data-start=\"3525\" data-end=\"3531\"\u003eLogs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3534\" data-end=\"3550\"\u003e\n\u003cp data-start=\"3536\" data-end=\"3550\"\u003eFault Alarms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3552\" data-end=\"3555\"\u003e\n\u003ch2 data-start=\"3557\" data-end=\"3570\"\u003eProtection\u003c\/h2\u003e\n\u003cul data-start=\"3571\" data-end=\"3734\"\u003e\n\u003cli data-start=\"3571\" data-end=\"3650\"\u003e\n\u003cp data-start=\"3573\" data-end=\"3594\"\u003e\u003cstrong data-start=\"3573\" data-end=\"3592\"\u003eESD Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3597\" data-end=\"3650\"\u003e\n\u003cli data-start=\"3597\" data-end=\"3620\"\u003e\n\u003cp data-start=\"3599\" data-end=\"3620\"\u003eAir Discharge: 8 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3623\" data-end=\"3650\"\u003e\n\u003cp data-start=\"3625\" data-end=\"3650\"\u003eContact Discharge: 6 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3651\" data-end=\"3734\"\u003e\n\u003cp data-start=\"3653\" data-end=\"3680\"\u003e\u003cstrong data-start=\"3653\" data-end=\"3678\"\u003eLightning Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3683\" data-end=\"3734\"\u003e\n\u003cli data-start=\"3683\" data-end=\"3704\"\u003e\n\u003cp data-start=\"3685\" data-end=\"3704\"\u003eCommon Mode: 6 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3707\" data-end=\"3734\"\u003e\n\u003cp data-start=\"3709\" data-end=\"3734\"\u003eDifferential Mode: 1 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3736\" data-end=\"3739\"\u003e\n\u003ch2 data-start=\"3741\" data-end=\"3767\"\u003ePhysical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"3768\" data-end=\"4041\"\u003e\n\u003cli data-start=\"3768\" data-end=\"3805\"\u003e\n\u003cp data-start=\"3770\" data-end=\"3805\"\u003e\u003cstrong data-start=\"3770\" data-end=\"3785\"\u003eNet Weight:\u003c\/strong\u003e 0.36 kg (0.79 lb)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3806\" data-end=\"3845\"\u003e\n\u003cp data-start=\"3808\" data-end=\"3845\"\u003e\u003cstrong data-start=\"3808\" data-end=\"3825\"\u003eGross Weight:\u003c\/strong\u003e 1.13 kg (2.49 lb)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3846\" data-end=\"3925\"\u003e\n\u003cp data-start=\"3848\" data-end=\"3873\"\u003e\u003cstrong data-start=\"3848\" data-end=\"3871\"\u003eProduct Dimensions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3876\" data-end=\"3925\"\u003e\n\u003cli data-start=\"3876\" data-end=\"3925\"\u003e\n\u003cp data-start=\"3878\" data-end=\"3925\"\u003e184.6 × 103.3 × 27 mm (7.27\" × 4.07\" × 1.06\")\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3926\" data-end=\"4004\"\u003e\n\u003cp data-start=\"3928\" data-end=\"3955\"\u003e\u003cstrong data-start=\"3928\" data-end=\"3953\"\u003ePackaging Dimensions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3958\" data-end=\"4004\"\u003e\n\u003cli data-start=\"3958\" data-end=\"4004\"\u003e\n\u003cp data-start=\"3960\" data-end=\"4004\"\u003e252 × 137 × 113 mm (9.92\" × 5.39\" × 4.45\")\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4005\" data-end=\"4041\"\u003e\n\u003cp data-start=\"4007\" data-end=\"4041\"\u003e\u003cstrong data-start=\"4007\" data-end=\"4027\"\u003eCasing Material:\u003c\/strong\u003e Sheet metal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4043\" data-end=\"4046\"\u003e\n\u003ch2 data-start=\"4048\" data-end=\"4063\"\u003eInstallation\u003c\/h2\u003e\n\u003cul data-start=\"4064\" data-end=\"4115\"\u003e\n\u003cli data-start=\"4064\" data-end=\"4115\"\u003e\n\u003cp data-start=\"4066\" data-end=\"4115\"\u003e\u003cstrong data-start=\"4066\" data-end=\"4087\"\u003eMounting Options:\u003c\/strong\u003e Desktop mount, Wall mount\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4117\" data-end=\"4120\"\u003e\n\u003ch2 data-start=\"4122\" data-end=\"4139\"\u003eCertifications\u003c\/h2\u003e\n\u003cul data-start=\"4140\" data-end=\"4148\"\u003e\n\u003cli data-start=\"4140\" data-end=\"4148\"\u003e\n\u003cp data-start=\"4142\" data-end=\"4148\"\u003e\u003cstrong data-start=\"4142\" data-end=\"4148\"\u003eCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4150\" data-end=\"4153\"\u003e\n\u003ch2 data-start=\"4155\" data-end=\"4170\"\u003ePacking List\u003c\/h2\u003e\n\u003cul data-start=\"4171\" data-end=\"4272\"\u003e\n\u003cli data-start=\"4171\" data-end=\"4190\"\u003e\n\u003cp data-start=\"4173\" data-end=\"4190\"\u003e1 × User Manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4191\" data-end=\"4231\"\u003e\n\u003cp data-start=\"4193\" data-end=\"4231\"\u003e1 × Legal and Regulatory Information\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4232\" data-end=\"4253\"\u003e\n\u003cp data-start=\"4234\" data-end=\"4253\"\u003e1 × Power Adapter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4254\" data-end=\"4272\"\u003e\n\u003cp data-start=\"4256\" data-end=\"4272\"\u003e1 × Power Cord\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 3 Year Dahua ANZ Manufacturer Warranty\u003c\/p\u003e","published_at":"2026-04-15T12:20:03+10:00","created_at":"2026-04-15T12:20:05+10:00","vendor":"Dahua","type":"Dahua PoE Switch","tags":["Australian Warranty","brand-Dahua","CCTV","Dahua","Dahua PoE Switch","DH-CS4010-8GT-110","Network Switch","PoE","PoE Switch","Security","Security Camera","Tekcart","type-Switch"],"price":23256,"price_min":23256,"price_max":23256,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":43221619703897,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"DH-CS4010-8GT-110","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Dahua CS4010-8GT-110 10-Port Cloud Managed Desktop Gigabit Switch with 8-Port POE","public_title":null,"options":["Default Title"],"price":23256,"weight":0,"compare_at_price":null,"inventory_management":"shopify","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/tekcart.com.au\/cdn\/shop\/files\/CS4010-8GT-110.png?v=1776219605"],"featured_image":"\/\/tekcart.com.au\/cdn\/shop\/files\/CS4010-8GT-110.png?v=1776219605","options":["Title"],"media":[{"alt":null,"id":28080822911065,"position":1,"preview_image":{"aspect_ratio":1.531,"height":1092,"width":1672,"src":"\/\/tekcart.com.au\/cdn\/shop\/files\/CS4010-8GT-110.png?v=1776219605"},"aspect_ratio":1.531,"height":1092,"media_type":"image","src":"\/\/tekcart.com.au\/cdn\/shop\/files\/CS4010-8GT-110.png?v=1776219605","width":1672}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch2 data-start=\"153\" data-end=\"220\"\u003e10-Port Cloud Managed Desktop \u003cstrong data-start=\"186\" data-end=\"197\"\u003eGigabit\u003c\/strong\u003e Switch with 8-Port PoE\u003c\/h2\u003e\n\u003ch3 data-start=\"222\" data-end=\"238\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"239\" data-end=\"804\"\u003e\n\u003cli data-start=\"239\" data-end=\"308\"\u003e\n\u003cp data-start=\"241\" data-end=\"308\"\u003e\u003cstrong data-start=\"241\" data-end=\"272\"\u003e8 × RJ-45 Gigabit PoE ports\u003c\/strong\u003e, \u003cstrong data-start=\"274\" data-end=\"308\"\u003e2 × RJ-45 Gigabit uplink ports\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"309\" data-end=\"432\"\u003e\n\u003cp data-start=\"311\" data-end=\"339\"\u003e\u003cstrong data-start=\"311\" data-end=\"337\"\u003e110 W total PoE budget\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"342\" data-end=\"432\"\u003e\n\u003cli data-start=\"342\" data-end=\"378\"\u003e\n\u003cp data-start=\"344\" data-end=\"378\"\u003eIEEE 802.3af\/at on all PoE ports\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"381\" data-end=\"432\"\u003e\n\u003cp data-start=\"383\" data-end=\"432\"\u003e\u003cstrong data-start=\"383\" data-end=\"432\"\u003eIEEE 802.3bt support on Ports 1–2 (red ports)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"433\" data-end=\"552\"\u003e\n\u003cp data-start=\"435\" data-end=\"474\"\u003e\u003cstrong data-start=\"435\" data-end=\"449\"\u003eDIP switch\u003c\/strong\u003e for fast mode switching:\u003c\/p\u003e\n\u003cul data-start=\"477\" data-end=\"552\"\u003e\n\u003cli data-start=\"477\" data-end=\"511\"\u003e\n\u003cp data-start=\"479\" data-end=\"511\"\u003eCloud-Managed \/ Unmanaged Mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"514\" data-end=\"530\"\u003e\n\u003cp data-start=\"516\" data-end=\"530\"\u003ePoE Watchdog\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"533\" data-end=\"552\"\u003e\n\u003cp data-start=\"535\" data-end=\"552\"\u003eLong-Distance PoE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"553\" data-end=\"603\"\u003e\n\u003cp data-start=\"555\" data-end=\"603\"\u003e\u003cstrong data-start=\"555\" data-end=\"586\"\u003eWide operating temperature:\u003c\/strong\u003e –10 °C to +55 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"604\" data-end=\"660\"\u003e\n\u003cp data-start=\"606\" data-end=\"660\"\u003eSupports \u003cstrong data-start=\"615\" data-end=\"634\"\u003eVLAN, STP, RSTP\u003c\/strong\u003e, and \u003cstrong data-start=\"640\" data-end=\"660\"\u003elink aggregation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"661\" data-end=\"734\"\u003e\n\u003cp data-start=\"663\" data-end=\"734\"\u003e\u003cstrong data-start=\"663\" data-end=\"678\"\u003eWeb-managed\u003c\/strong\u003e and \u003cstrong data-start=\"683\" data-end=\"715\"\u003ecentralised cloud management\u003c\/strong\u003e via \u003cstrong data-start=\"720\" data-end=\"734\"\u003eDoLynk App\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"735\" data-end=\"804\"\u003e\n\u003cp data-start=\"737\" data-end=\"804\"\u003eEasy configuration with \u003cstrong data-start=\"761\" data-end=\"804\"\u003eauto network detection and system setup\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"735\" data-end=\"804\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0047\/9510\/5391\/files\/DH-CS4010-8GT-110_V2_datasheet_20251104.pdf?v=1765923577\"\u003e\u003cstrong data-start=\"761\" data-end=\"804\"\u003eDatasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"806\" data-end=\"809\"\u003e\n\u003ch2 data-start=\"811\" data-end=\"834\"\u003eBasic Specifications\u003c\/h2\u003e\n\u003cul data-start=\"835\" data-end=\"946\"\u003e\n\u003cli data-start=\"835\" data-end=\"867\"\u003e\n\u003cp data-start=\"837\" data-end=\"867\"\u003e\u003cstrong data-start=\"837\" data-end=\"857\"\u003eSwitching Layer:\u003c\/strong\u003e Layer 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"868\" data-end=\"903\"\u003e\n\u003cp data-start=\"870\" data-end=\"903\"\u003e\u003cstrong data-start=\"870\" data-end=\"893\"\u003eSwitching Capacity:\u003c\/strong\u003e 20 Gbps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"904\" data-end=\"946\"\u003e\n\u003cp data-start=\"906\" data-end=\"946\"\u003e\u003cstrong data-start=\"906\" data-end=\"933\"\u003ePacket Forwarding Rate:\u003c\/strong\u003e 14.88 Mpps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"948\" data-end=\"951\"\u003e\n\u003ch2 data-start=\"953\" data-end=\"974\"\u003ePort Configuration\u003c\/h2\u003e\n\u003cul data-start=\"975\" data-end=\"1090\"\u003e\n\u003cli data-start=\"975\" data-end=\"1026\"\u003e\n\u003cp data-start=\"977\" data-end=\"1026\"\u003e\u003cstrong data-start=\"977\" data-end=\"991\"\u003ePorts 1–8:\u003c\/strong\u003e 8 × RJ-45 10\/100\/1000 Mbps (PoE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1027\" data-end=\"1090\"\u003e\n\u003cp data-start=\"1029\" data-end=\"1090\"\u003e\u003cstrong data-start=\"1029\" data-end=\"1044\"\u003ePorts 9–10:\u003c\/strong\u003e 2 × RJ-45 10\/100\/1000 Mbps (Gigabit uplink)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1092\" data-end=\"1095\"\u003e\n\u003ch2 data-start=\"1097\" data-end=\"1128\"\u003eEnvironmental Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1129\" data-end=\"1371\"\u003e\n\u003cli data-start=\"1129\" data-end=\"1196\"\u003e\n\u003cp data-start=\"1131\" data-end=\"1196\"\u003e\u003cstrong data-start=\"1131\" data-end=\"1157\"\u003eOperating Temperature:\u003c\/strong\u003e –10 °C to +55 °C (+14 °F to +131 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1197\" data-end=\"1252\"\u003e\n\u003cp data-start=\"1199\" data-end=\"1252\"\u003e\u003cstrong data-start=\"1199\" data-end=\"1222\"\u003eOperating Humidity:\u003c\/strong\u003e 10%–90% RH (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1253\" data-end=\"1318\"\u003e\n\u003cp data-start=\"1255\" data-end=\"1318\"\u003e\u003cstrong data-start=\"1255\" data-end=\"1279\"\u003eStorage Temperature:\u003c\/strong\u003e –40 °C to +75 °C (–40 °F to +167 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1319\" data-end=\"1371\"\u003e\n\u003cp data-start=\"1321\" data-end=\"1371\"\u003e\u003cstrong data-start=\"1321\" data-end=\"1342\"\u003eStorage Humidity:\u003c\/strong\u003e 5%–95% RH (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1373\" data-end=\"1376\"\u003e\n\u003ch2 data-start=\"1378\" data-end=\"1386\"\u003ePower\u003c\/h2\u003e\n\u003cul data-start=\"1387\" data-end=\"1516\"\u003e\n\u003cli data-start=\"1387\" data-end=\"1448\"\u003e\n\u003cp data-start=\"1389\" data-end=\"1448\"\u003e\u003cstrong data-start=\"1389\" data-end=\"1406\"\u003ePower Supply:\u003c\/strong\u003e External power adapter, 54 VDC \/ 2.22 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1449\" data-end=\"1516\"\u003e\n\u003cp data-start=\"1451\" data-end=\"1475\"\u003e\u003cstrong data-start=\"1451\" data-end=\"1473\"\u003ePower Consumption:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1478\" data-end=\"1516\"\u003e\n\u003cli data-start=\"1478\" data-end=\"1493\"\u003e\n\u003cp data-start=\"1480\" data-end=\"1493\"\u003eIdle: 5.7 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1496\" data-end=\"1516\"\u003e\n\u003cp data-start=\"1498\" data-end=\"1516\"\u003eFull Load: 115 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1518\" data-end=\"1521\"\u003e\n\u003ch2 data-start=\"1523\" data-end=\"1544\"\u003ePoE Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1545\" data-end=\"2096\"\u003e\n\u003cli data-start=\"1545\" data-end=\"1569\"\u003e\n\u003cp data-start=\"1547\" data-end=\"1569\"\u003e\u003cstrong data-start=\"1547\" data-end=\"1563\"\u003ePoE Support:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1570\" data-end=\"1644\"\u003e\n\u003cp data-start=\"1572\" data-end=\"1644\"\u003e\u003cstrong data-start=\"1572\" data-end=\"1590\"\u003ePoE Protocols:\u003c\/strong\u003e IEEE 802.3af \/ IEEE 802.3at \/ Hi-PoE \/ IEEE 802.3bt\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1645\" data-end=\"1772\"\u003e\n\u003cp data-start=\"1647\" data-end=\"1670\"\u003e\u003cstrong data-start=\"1647\" data-end=\"1668\"\u003ePoE Output Power:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1673\" data-end=\"1772\"\u003e\n\u003cli data-start=\"1673\" data-end=\"1703\"\u003e\n\u003cp data-start=\"1675\" data-end=\"1703\"\u003ePorts 1–2: ≤ 90 W per port\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1706\" data-end=\"1736\"\u003e\n\u003cp data-start=\"1708\" data-end=\"1736\"\u003ePorts 3–8: ≤ 30 W per port\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1739\" data-end=\"1772\"\u003e\n\u003cp data-start=\"1741\" data-end=\"1772\"\u003e\u003cstrong data-start=\"1741\" data-end=\"1762\"\u003eTotal PoE Budget:\u003c\/strong\u003e ≤ 110 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1773\" data-end=\"1915\"\u003e\n\u003cp data-start=\"1775\" data-end=\"1802\"\u003e\u003cstrong data-start=\"1775\" data-end=\"1800\"\u003ePoE Power Management:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1805\" data-end=\"1915\"\u003e\n\u003cli data-start=\"1805\" data-end=\"1841\"\u003e\n\u003cp data-start=\"1807\" data-end=\"1841\"\u003ePoE power consumption management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1844\" data-end=\"1864\"\u003e\n\u003cp data-start=\"1846\" data-end=\"1864\"\u003ePoE power on\/off\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1867\" data-end=\"1915\"\u003e\n\u003cp data-start=\"1869\" data-end=\"1915\"\u003eAutomatic PoE shutdown on overload detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1916\" data-end=\"2065\"\u003e\n\u003cp data-start=\"1918\" data-end=\"1943\"\u003e\u003cstrong data-start=\"1918\" data-end=\"1941\"\u003ePoE Pin Assignment:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1946\" data-end=\"2065\"\u003e\n\u003cli data-start=\"1946\" data-end=\"2010\"\u003e\n\u003cp data-start=\"1948\" data-end=\"1964\"\u003e\u003cstrong data-start=\"1948\" data-end=\"1962\"\u003ePorts 1–2:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1969\" data-end=\"2010\"\u003e\n\u003cli data-start=\"1969\" data-end=\"1987\"\u003e\n\u003cp data-start=\"1971\" data-end=\"1987\"\u003eV+: 1, 2, 4, 5\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1992\" data-end=\"2010\"\u003e\n\u003cp data-start=\"1994\" data-end=\"2010\"\u003eV–: 3, 6, 7, 8\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2013\" data-end=\"2065\"\u003e\n\u003cp data-start=\"2015\" data-end=\"2031\"\u003e\u003cstrong data-start=\"2015\" data-end=\"2029\"\u003ePorts 3–8:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2036\" data-end=\"2065\"\u003e\n\u003cli data-start=\"2036\" data-end=\"2048\"\u003e\n\u003cp data-start=\"2038\" data-end=\"2048\"\u003eV+: 1, 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2053\" data-end=\"2065\"\u003e\n\u003cp data-start=\"2055\" data-end=\"2065\"\u003eV–: 3, 6\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2066\" data-end=\"2096\"\u003e\n\u003cp data-start=\"2068\" data-end=\"2096\"\u003e\u003cstrong data-start=\"2068\" data-end=\"2090\"\u003eLong-Distance PoE:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2098\" data-end=\"2101\"\u003e\n\u003ch2 data-start=\"2103\" data-end=\"2123\"\u003eHardware Features\u003c\/h2\u003e\n\u003ch3 data-start=\"2124\" data-end=\"2148\"\u003eDIP Switch Functions\u003c\/h3\u003e\n\u003cul data-start=\"2149\" data-end=\"2563\"\u003e\n\u003cli data-start=\"2149\" data-end=\"2243\"\u003e\n\u003cp data-start=\"2151\" data-end=\"2170\"\u003e\u003cstrong data-start=\"2151\" data-end=\"2168\"\u003eManaged Mode:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2173\" data-end=\"2243\"\u003e\n\u003cli data-start=\"2173\" data-end=\"2219\"\u003e\n\u003cp data-start=\"2175\" data-end=\"2219\"\u003eON (default): Local web + cloud management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2222\" data-end=\"2243\"\u003e\n\u003cp data-start=\"2224\" data-end=\"2243\"\u003eOFF: Unmanaged mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2244\" data-end=\"2406\"\u003e\n\u003cp data-start=\"2246\" data-end=\"2265\"\u003e\u003cstrong data-start=\"2246\" data-end=\"2263\"\u003ePoE Watchdog:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2268\" data-end=\"2406\"\u003e\n\u003cli data-start=\"2268\" data-end=\"2290\"\u003e\n\u003cp data-start=\"2270\" data-end=\"2290\"\u003eMonitors ports 1–8\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2293\" data-end=\"2363\"\u003e\n\u003cp data-start=\"2295\" data-end=\"2363\"\u003eAutomatically restarts PoE if no traffic is detected for 2 minutes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2366\" data-end=\"2406\"\u003e\n\u003cp data-start=\"2368\" data-end=\"2406\"\u003e\u003cem data-start=\"2368\" data-end=\"2406\"\u003eOnly active when Managed Mode is OFF\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2407\" data-end=\"2538\"\u003e\n\u003cp data-start=\"2409\" data-end=\"2427\"\u003e\u003cstrong data-start=\"2409\" data-end=\"2425\"\u003eExtend Mode:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2430\" data-end=\"2538\"\u003e\n\u003cli data-start=\"2430\" data-end=\"2495\"\u003e\n\u003cp data-start=\"2432\" data-end=\"2495\"\u003ePorts 1–8 support up to \u003cstrong data-start=\"2456\" data-end=\"2465\"\u003e250 m\u003c\/strong\u003e transmission at \u003cstrong data-start=\"2482\" data-end=\"2493\"\u003e10 Mbps\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2498\" data-end=\"2538\"\u003e\n\u003cp data-start=\"2500\" data-end=\"2538\"\u003e\u003cem data-start=\"2500\" data-end=\"2538\"\u003eOnly active when Managed Mode is OFF\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2540\" data-end=\"2563\"\u003e\n\u003cp data-start=\"2542\" data-end=\"2563\"\u003e\u003cstrong data-start=\"2542\" data-end=\"2559\"\u003eReset Button:\u003c\/strong\u003e 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2565\" data-end=\"2568\"\u003e\n\u003ch2 data-start=\"2570\" data-end=\"2584\"\u003ePerformance\u003c\/h2\u003e\n\u003cul data-start=\"2585\" data-end=\"2736\"\u003e\n\u003cli data-start=\"2585\" data-end=\"2614\"\u003e\n\u003cp data-start=\"2587\" data-end=\"2614\"\u003e\u003cstrong data-start=\"2587\" data-end=\"2596\"\u003eMTBF:\u003c\/strong\u003e 2,482,955 hours\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2615\" data-end=\"2644\"\u003e\n\u003cp data-start=\"2617\" data-end=\"2644\"\u003e\u003cstrong data-start=\"2617\" data-end=\"2635\"\u003ePacket Buffer:\u003c\/strong\u003e 4 Mbit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2645\" data-end=\"2678\"\u003e\n\u003cp data-start=\"2647\" data-end=\"2678\"\u003e\u003cstrong data-start=\"2647\" data-end=\"2663\"\u003eJumbo Frame:\u003c\/strong\u003e 15,360 Bytes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2679\" data-end=\"2708\"\u003e\n\u003cp data-start=\"2681\" data-end=\"2708\"\u003e\u003cstrong data-start=\"2681\" data-end=\"2703\"\u003eMAC Address Table:\u003c\/strong\u003e 8K\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2709\" data-end=\"2736\"\u003e\n\u003cp data-start=\"2711\" data-end=\"2736\"\u003e\u003cstrong data-start=\"2711\" data-end=\"2731\"\u003eSupported VLANs:\u003c\/strong\u003e 32\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2738\" data-end=\"2741\"\u003e\n\u003ch2 data-start=\"2743\" data-end=\"2763\"\u003eNetwork Standards\u003c\/h2\u003e\n\u003cul data-start=\"2764\" data-end=\"2897\"\u003e\n\u003cli data-start=\"2764\" data-end=\"2897\"\u003e\n\u003cp data-start=\"2766\" data-end=\"2787\"\u003e\u003cstrong data-start=\"2766\" data-end=\"2785\"\u003eIEEE Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2790\" data-end=\"2897\"\u003e\n\u003cli data-start=\"2790\" data-end=\"2804\"\u003e\n\u003cp data-start=\"2792\" data-end=\"2804\"\u003eIEEE 802.3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2807\" data-end=\"2822\"\u003e\n\u003cp data-start=\"2809\" data-end=\"2822\"\u003eIEEE 802.3u\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2825\" data-end=\"2840\"\u003e\n\u003cp data-start=\"2827\" data-end=\"2840\"\u003eIEEE 802.3x\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2843\" data-end=\"2859\"\u003e\n\u003cp data-start=\"2845\" data-end=\"2859\"\u003eIEEE 802.3ab\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2862\" data-end=\"2878\"\u003e\n\u003cp data-start=\"2864\" data-end=\"2878\"\u003eIEEE 802.3az\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2881\" data-end=\"2897\"\u003e\n\u003cp data-start=\"2883\" data-end=\"2897\"\u003eIEEE 802.3ad\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2899\" data-end=\"2902\"\u003e\n\u003ch2 data-start=\"2904\" data-end=\"2923\"\u003eNetwork Features\u003c\/h2\u003e\n\u003cul data-start=\"2924\" data-end=\"3394\"\u003e\n\u003cli data-start=\"2924\" data-end=\"2967\"\u003e\n\u003cp data-start=\"2926\" data-end=\"2967\"\u003e\u003cstrong data-start=\"2926\" data-end=\"2955\"\u003eEthernet Loop Protection:\u003c\/strong\u003e STP, RSTP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2968\" data-end=\"2998\"\u003e\n\u003cp data-start=\"2970\" data-end=\"2998\"\u003e\u003cstrong data-start=\"2970\" data-end=\"2979\"\u003eVLAN:\u003c\/strong\u003e IEEE 802.1Q VLAN\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2999\" data-end=\"3043\"\u003e\n\u003cp data-start=\"3001\" data-end=\"3043\"\u003e\u003cstrong data-start=\"3001\" data-end=\"3022\"\u003eLink Aggregation:\u003c\/strong\u003e Static aggregation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3044\" data-end=\"3238\"\u003e\n\u003cp data-start=\"3046\" data-end=\"3066\"\u003e\u003cstrong data-start=\"3046\" data-end=\"3064\"\u003ePort Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3069\" data-end=\"3238\"\u003e\n\u003cli data-start=\"3069\" data-end=\"3097\"\u003e\n\u003cp data-start=\"3071\" data-end=\"3097\"\u003eIEEE 802.3x Flow Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3100\" data-end=\"3131\"\u003e\n\u003cp data-start=\"3102\" data-end=\"3131\"\u003eUnknown Unicast Suppression\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3134\" data-end=\"3161\"\u003e\n\u003cp data-start=\"3136\" data-end=\"3161\"\u003eMulticast Storm Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3164\" data-end=\"3191\"\u003e\n\u003cp data-start=\"3166\" data-end=\"3191\"\u003eBroadcast Storm Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3194\" data-end=\"3216\"\u003e\n\u003cp data-start=\"3196\" data-end=\"3216\"\u003eMAC + Port Binding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3219\" data-end=\"3238\"\u003e\n\u003cp data-start=\"3221\" data-end=\"3238\"\u003eLoop Prevention\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3239\" data-end=\"3309\"\u003e\n\u003cp data-start=\"3241\" data-end=\"3262\"\u003e\u003cstrong data-start=\"3241\" data-end=\"3260\"\u003ePort Mirroring:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3265\" data-end=\"3309\"\u003e\n\u003cli data-start=\"3265\" data-end=\"3289\"\u003e\n\u003cp data-start=\"3267\" data-end=\"3289\"\u003eLocal Port Mirroring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3292\" data-end=\"3309\"\u003e\n\u003cp data-start=\"3294\" data-end=\"3309\"\u003eN:1 Mirroring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3310\" data-end=\"3335\"\u003e\n\u003cp data-start=\"3312\" data-end=\"3335\"\u003e\u003cstrong data-start=\"3312\" data-end=\"3329\"\u003eLLDP Support:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3336\" data-end=\"3361\"\u003e\n\u003cp data-start=\"3338\" data-end=\"3361\"\u003e\u003cstrong data-start=\"3338\" data-end=\"3347\"\u003eDHCP:\u003c\/strong\u003e DHCP Client\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3362\" data-end=\"3394\"\u003e\n\u003cp data-start=\"3364\" data-end=\"3394\"\u003e\u003cstrong data-start=\"3364\" data-end=\"3377\"\u003eSecurity:\u003c\/strong\u003e Port Isolation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3396\" data-end=\"3399\"\u003e\n\u003ch2 data-start=\"3401\" data-end=\"3414\"\u003eManagement\u003c\/h2\u003e\n\u003cul data-start=\"3415\" data-end=\"3550\"\u003e\n\u003cli data-start=\"3415\" data-end=\"3486\"\u003e\n\u003cp data-start=\"3417\" data-end=\"3442\"\u003e\u003cstrong data-start=\"3417\" data-end=\"3440\"\u003eManagement Methods:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3445\" data-end=\"3486\"\u003e\n\u003cli data-start=\"3445\" data-end=\"3463\"\u003e\n\u003cp data-start=\"3447\" data-end=\"3463\"\u003eWeb Management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3466\" data-end=\"3486\"\u003e\n\u003cp data-start=\"3468\" data-end=\"3486\"\u003eCloud Management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3487\" data-end=\"3550\"\u003e\n\u003cp data-start=\"3489\" data-end=\"3520\"\u003e\u003cstrong data-start=\"3489\" data-end=\"3518\"\u003eMonitoring \u0026amp; Maintenance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3523\" data-end=\"3550\"\u003e\n\u003cli data-start=\"3523\" data-end=\"3531\"\u003e\n\u003cp data-start=\"3525\" data-end=\"3531\"\u003eLogs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3534\" data-end=\"3550\"\u003e\n\u003cp data-start=\"3536\" data-end=\"3550\"\u003eFault Alarms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3552\" data-end=\"3555\"\u003e\n\u003ch2 data-start=\"3557\" data-end=\"3570\"\u003eProtection\u003c\/h2\u003e\n\u003cul data-start=\"3571\" data-end=\"3734\"\u003e\n\u003cli data-start=\"3571\" data-end=\"3650\"\u003e\n\u003cp data-start=\"3573\" data-end=\"3594\"\u003e\u003cstrong data-start=\"3573\" data-end=\"3592\"\u003eESD Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3597\" data-end=\"3650\"\u003e\n\u003cli data-start=\"3597\" data-end=\"3620\"\u003e\n\u003cp data-start=\"3599\" data-end=\"3620\"\u003eAir Discharge: 8 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3623\" data-end=\"3650\"\u003e\n\u003cp data-start=\"3625\" data-end=\"3650\"\u003eContact Discharge: 6 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3651\" data-end=\"3734\"\u003e\n\u003cp data-start=\"3653\" data-end=\"3680\"\u003e\u003cstrong data-start=\"3653\" data-end=\"3678\"\u003eLightning Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3683\" data-end=\"3734\"\u003e\n\u003cli data-start=\"3683\" data-end=\"3704\"\u003e\n\u003cp data-start=\"3685\" data-end=\"3704\"\u003eCommon Mode: 6 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3707\" data-end=\"3734\"\u003e\n\u003cp data-start=\"3709\" data-end=\"3734\"\u003eDifferential Mode: 1 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3736\" data-end=\"3739\"\u003e\n\u003ch2 data-start=\"3741\" data-end=\"3767\"\u003ePhysical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"3768\" data-end=\"4041\"\u003e\n\u003cli data-start=\"3768\" data-end=\"3805\"\u003e\n\u003cp data-start=\"3770\" data-end=\"3805\"\u003e\u003cstrong data-start=\"3770\" data-end=\"3785\"\u003eNet Weight:\u003c\/strong\u003e 0.36 kg (0.79 lb)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3806\" data-end=\"3845\"\u003e\n\u003cp data-start=\"3808\" data-end=\"3845\"\u003e\u003cstrong data-start=\"3808\" data-end=\"3825\"\u003eGross Weight:\u003c\/strong\u003e 1.13 kg (2.49 lb)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3846\" data-end=\"3925\"\u003e\n\u003cp data-start=\"3848\" data-end=\"3873\"\u003e\u003cstrong data-start=\"3848\" data-end=\"3871\"\u003eProduct Dimensions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3876\" data-end=\"3925\"\u003e\n\u003cli data-start=\"3876\" data-end=\"3925\"\u003e\n\u003cp data-start=\"3878\" data-end=\"3925\"\u003e184.6 × 103.3 × 27 mm (7.27\" × 4.07\" × 1.06\")\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3926\" data-end=\"4004\"\u003e\n\u003cp data-start=\"3928\" data-end=\"3955\"\u003e\u003cstrong data-start=\"3928\" data-end=\"3953\"\u003ePackaging Dimensions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3958\" data-end=\"4004\"\u003e\n\u003cli data-start=\"3958\" data-end=\"4004\"\u003e\n\u003cp data-start=\"3960\" data-end=\"4004\"\u003e252 × 137 × 113 mm (9.92\" × 5.39\" × 4.45\")\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4005\" data-end=\"4041\"\u003e\n\u003cp data-start=\"4007\" data-end=\"4041\"\u003e\u003cstrong data-start=\"4007\" data-end=\"4027\"\u003eCasing Material:\u003c\/strong\u003e Sheet metal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4043\" data-end=\"4046\"\u003e\n\u003ch2 data-start=\"4048\" data-end=\"4063\"\u003eInstallation\u003c\/h2\u003e\n\u003cul data-start=\"4064\" data-end=\"4115\"\u003e\n\u003cli data-start=\"4064\" data-end=\"4115\"\u003e\n\u003cp data-start=\"4066\" data-end=\"4115\"\u003e\u003cstrong data-start=\"4066\" data-end=\"4087\"\u003eMounting Options:\u003c\/strong\u003e Desktop mount, Wall mount\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4117\" data-end=\"4120\"\u003e\n\u003ch2 data-start=\"4122\" data-end=\"4139\"\u003eCertifications\u003c\/h2\u003e\n\u003cul data-start=\"4140\" data-end=\"4148\"\u003e\n\u003cli data-start=\"4140\" data-end=\"4148\"\u003e\n\u003cp data-start=\"4142\" data-end=\"4148\"\u003e\u003cstrong data-start=\"4142\" data-end=\"4148\"\u003eCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4150\" data-end=\"4153\"\u003e\n\u003ch2 data-start=\"4155\" data-end=\"4170\"\u003ePacking List\u003c\/h2\u003e\n\u003cul data-start=\"4171\" data-end=\"4272\"\u003e\n\u003cli data-start=\"4171\" data-end=\"4190\"\u003e\n\u003cp data-start=\"4173\" data-end=\"4190\"\u003e1 × User Manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4191\" data-end=\"4231\"\u003e\n\u003cp data-start=\"4193\" data-end=\"4231\"\u003e1 × Legal and Regulatory Information\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4232\" data-end=\"4253\"\u003e\n\u003cp data-start=\"4234\" data-end=\"4253\"\u003e1 × Power Adapter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4254\" data-end=\"4272\"\u003e\n\u003cp data-start=\"4256\" data-end=\"4272\"\u003e1 × Power Cord\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 3 Year Dahua ANZ Manufacturer Warranty\u003c\/p\u003e"}
Translation missing: en.products.product.regular_price $129.00 -
-
{"id":8191822069849,"title":"Dahua CS4010-8GT-110 10-Port Cloud Managed Desktop Gigabit Switch with 8-Port POE","handle":"cs4010-8gt-110-dahua-10-port-cloud-managed-desktop-gigabit-switch-with-8-port-poe","description":"\u003ch2 data-start=\"153\" data-end=\"220\"\u003e10-Port Cloud Managed Desktop \u003cstrong data-start=\"186\" data-end=\"197\"\u003eGigabit\u003c\/strong\u003e Switch with 8-Port PoE\u003c\/h2\u003e\n\u003ch3 data-start=\"222\" data-end=\"238\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"239\" data-end=\"804\"\u003e\n\u003cli data-start=\"239\" data-end=\"308\"\u003e\n\u003cp data-start=\"241\" data-end=\"308\"\u003e\u003cstrong data-start=\"241\" data-end=\"272\"\u003e8 × RJ-45 Gigabit PoE ports\u003c\/strong\u003e, \u003cstrong data-start=\"274\" data-end=\"308\"\u003e2 × RJ-45 Gigabit uplink ports\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"309\" data-end=\"432\"\u003e\n\u003cp data-start=\"311\" data-end=\"339\"\u003e\u003cstrong data-start=\"311\" data-end=\"337\"\u003e110 W total PoE budget\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"342\" data-end=\"432\"\u003e\n\u003cli data-start=\"342\" data-end=\"378\"\u003e\n\u003cp data-start=\"344\" data-end=\"378\"\u003eIEEE 802.3af\/at on all PoE ports\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"381\" data-end=\"432\"\u003e\n\u003cp data-start=\"383\" data-end=\"432\"\u003e\u003cstrong data-start=\"383\" data-end=\"432\"\u003eIEEE 802.3bt support on Ports 1–2 (red ports)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"433\" data-end=\"552\"\u003e\n\u003cp data-start=\"435\" data-end=\"474\"\u003e\u003cstrong data-start=\"435\" data-end=\"449\"\u003eDIP switch\u003c\/strong\u003e for fast mode switching:\u003c\/p\u003e\n\u003cul data-start=\"477\" data-end=\"552\"\u003e\n\u003cli data-start=\"477\" data-end=\"511\"\u003e\n\u003cp data-start=\"479\" data-end=\"511\"\u003eCloud-Managed \/ Unmanaged Mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"514\" data-end=\"530\"\u003e\n\u003cp data-start=\"516\" data-end=\"530\"\u003ePoE Watchdog\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"533\" data-end=\"552\"\u003e\n\u003cp data-start=\"535\" data-end=\"552\"\u003eLong-Distance PoE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"553\" data-end=\"603\"\u003e\n\u003cp data-start=\"555\" data-end=\"603\"\u003e\u003cstrong data-start=\"555\" data-end=\"586\"\u003eWide operating temperature:\u003c\/strong\u003e –10 °C to +55 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"604\" data-end=\"660\"\u003e\n\u003cp data-start=\"606\" data-end=\"660\"\u003eSupports \u003cstrong data-start=\"615\" data-end=\"634\"\u003eVLAN, STP, RSTP\u003c\/strong\u003e, and \u003cstrong data-start=\"640\" data-end=\"660\"\u003elink aggregation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"661\" data-end=\"734\"\u003e\n\u003cp data-start=\"663\" data-end=\"734\"\u003e\u003cstrong data-start=\"663\" data-end=\"678\"\u003eWeb-managed\u003c\/strong\u003e and \u003cstrong data-start=\"683\" data-end=\"715\"\u003ecentralised cloud management\u003c\/strong\u003e via \u003cstrong data-start=\"720\" data-end=\"734\"\u003eDoLynk App\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"735\" data-end=\"804\"\u003e\n\u003cp data-start=\"737\" data-end=\"804\"\u003eEasy configuration with \u003cstrong data-start=\"761\" data-end=\"804\"\u003eauto network detection and system setup\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"735\" data-end=\"804\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0047\/9510\/5391\/files\/DH-CS4010-8GT-110_V2_datasheet_20251104.pdf?v=1765923577\"\u003e\u003cstrong data-start=\"761\" data-end=\"804\"\u003eDatasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"806\" data-end=\"809\"\u003e\n\u003ch2 data-start=\"811\" data-end=\"834\"\u003eBasic Specifications\u003c\/h2\u003e\n\u003cul data-start=\"835\" data-end=\"946\"\u003e\n\u003cli data-start=\"835\" data-end=\"867\"\u003e\n\u003cp data-start=\"837\" data-end=\"867\"\u003e\u003cstrong data-start=\"837\" data-end=\"857\"\u003eSwitching Layer:\u003c\/strong\u003e Layer 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"868\" data-end=\"903\"\u003e\n\u003cp data-start=\"870\" data-end=\"903\"\u003e\u003cstrong data-start=\"870\" data-end=\"893\"\u003eSwitching Capacity:\u003c\/strong\u003e 20 Gbps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"904\" data-end=\"946\"\u003e\n\u003cp data-start=\"906\" data-end=\"946\"\u003e\u003cstrong data-start=\"906\" data-end=\"933\"\u003ePacket Forwarding Rate:\u003c\/strong\u003e 14.88 Mpps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"948\" data-end=\"951\"\u003e\n\u003ch2 data-start=\"953\" data-end=\"974\"\u003ePort Configuration\u003c\/h2\u003e\n\u003cul data-start=\"975\" data-end=\"1090\"\u003e\n\u003cli data-start=\"975\" data-end=\"1026\"\u003e\n\u003cp data-start=\"977\" data-end=\"1026\"\u003e\u003cstrong data-start=\"977\" data-end=\"991\"\u003ePorts 1–8:\u003c\/strong\u003e 8 × RJ-45 10\/100\/1000 Mbps (PoE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1027\" data-end=\"1090\"\u003e\n\u003cp data-start=\"1029\" data-end=\"1090\"\u003e\u003cstrong data-start=\"1029\" data-end=\"1044\"\u003ePorts 9–10:\u003c\/strong\u003e 2 × RJ-45 10\/100\/1000 Mbps (Gigabit uplink)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1092\" data-end=\"1095\"\u003e\n\u003ch2 data-start=\"1097\" data-end=\"1128\"\u003eEnvironmental Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1129\" data-end=\"1371\"\u003e\n\u003cli data-start=\"1129\" data-end=\"1196\"\u003e\n\u003cp data-start=\"1131\" data-end=\"1196\"\u003e\u003cstrong data-start=\"1131\" data-end=\"1157\"\u003eOperating Temperature:\u003c\/strong\u003e –10 °C to +55 °C (+14 °F to +131 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1197\" data-end=\"1252\"\u003e\n\u003cp data-start=\"1199\" data-end=\"1252\"\u003e\u003cstrong data-start=\"1199\" data-end=\"1222\"\u003eOperating Humidity:\u003c\/strong\u003e 10%–90% RH (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1253\" data-end=\"1318\"\u003e\n\u003cp data-start=\"1255\" data-end=\"1318\"\u003e\u003cstrong data-start=\"1255\" data-end=\"1279\"\u003eStorage Temperature:\u003c\/strong\u003e –40 °C to +75 °C (–40 °F to +167 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1319\" data-end=\"1371\"\u003e\n\u003cp data-start=\"1321\" data-end=\"1371\"\u003e\u003cstrong data-start=\"1321\" data-end=\"1342\"\u003eStorage Humidity:\u003c\/strong\u003e 5%–95% RH (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1373\" data-end=\"1376\"\u003e\n\u003ch2 data-start=\"1378\" data-end=\"1386\"\u003ePower\u003c\/h2\u003e\n\u003cul data-start=\"1387\" data-end=\"1516\"\u003e\n\u003cli data-start=\"1387\" data-end=\"1448\"\u003e\n\u003cp data-start=\"1389\" data-end=\"1448\"\u003e\u003cstrong data-start=\"1389\" data-end=\"1406\"\u003ePower Supply:\u003c\/strong\u003e External power adapter, 54 VDC \/ 2.22 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1449\" data-end=\"1516\"\u003e\n\u003cp data-start=\"1451\" data-end=\"1475\"\u003e\u003cstrong data-start=\"1451\" data-end=\"1473\"\u003ePower Consumption:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1478\" data-end=\"1516\"\u003e\n\u003cli data-start=\"1478\" data-end=\"1493\"\u003e\n\u003cp data-start=\"1480\" data-end=\"1493\"\u003eIdle: 5.7 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1496\" data-end=\"1516\"\u003e\n\u003cp data-start=\"1498\" data-end=\"1516\"\u003eFull Load: 115 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1518\" data-end=\"1521\"\u003e\n\u003ch2 data-start=\"1523\" data-end=\"1544\"\u003ePoE Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1545\" data-end=\"2096\"\u003e\n\u003cli data-start=\"1545\" data-end=\"1569\"\u003e\n\u003cp data-start=\"1547\" data-end=\"1569\"\u003e\u003cstrong data-start=\"1547\" data-end=\"1563\"\u003ePoE Support:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1570\" data-end=\"1644\"\u003e\n\u003cp data-start=\"1572\" data-end=\"1644\"\u003e\u003cstrong data-start=\"1572\" data-end=\"1590\"\u003ePoE Protocols:\u003c\/strong\u003e IEEE 802.3af \/ IEEE 802.3at \/ Hi-PoE \/ IEEE 802.3bt\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1645\" data-end=\"1772\"\u003e\n\u003cp data-start=\"1647\" data-end=\"1670\"\u003e\u003cstrong data-start=\"1647\" data-end=\"1668\"\u003ePoE Output Power:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1673\" data-end=\"1772\"\u003e\n\u003cli data-start=\"1673\" data-end=\"1703\"\u003e\n\u003cp data-start=\"1675\" data-end=\"1703\"\u003ePorts 1–2: ≤ 90 W per port\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1706\" data-end=\"1736\"\u003e\n\u003cp data-start=\"1708\" data-end=\"1736\"\u003ePorts 3–8: ≤ 30 W per port\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1739\" data-end=\"1772\"\u003e\n\u003cp data-start=\"1741\" data-end=\"1772\"\u003e\u003cstrong data-start=\"1741\" data-end=\"1762\"\u003eTotal PoE Budget:\u003c\/strong\u003e ≤ 110 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1773\" data-end=\"1915\"\u003e\n\u003cp data-start=\"1775\" data-end=\"1802\"\u003e\u003cstrong data-start=\"1775\" data-end=\"1800\"\u003ePoE Power Management:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1805\" data-end=\"1915\"\u003e\n\u003cli data-start=\"1805\" data-end=\"1841\"\u003e\n\u003cp data-start=\"1807\" data-end=\"1841\"\u003ePoE power consumption management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1844\" data-end=\"1864\"\u003e\n\u003cp data-start=\"1846\" data-end=\"1864\"\u003ePoE power on\/off\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1867\" data-end=\"1915\"\u003e\n\u003cp data-start=\"1869\" data-end=\"1915\"\u003eAutomatic PoE shutdown on overload detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1916\" data-end=\"2065\"\u003e\n\u003cp data-start=\"1918\" data-end=\"1943\"\u003e\u003cstrong data-start=\"1918\" data-end=\"1941\"\u003ePoE Pin Assignment:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1946\" data-end=\"2065\"\u003e\n\u003cli data-start=\"1946\" data-end=\"2010\"\u003e\n\u003cp data-start=\"1948\" data-end=\"1964\"\u003e\u003cstrong data-start=\"1948\" data-end=\"1962\"\u003ePorts 1–2:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1969\" data-end=\"2010\"\u003e\n\u003cli data-start=\"1969\" data-end=\"1987\"\u003e\n\u003cp data-start=\"1971\" data-end=\"1987\"\u003eV+: 1, 2, 4, 5\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1992\" data-end=\"2010\"\u003e\n\u003cp data-start=\"1994\" data-end=\"2010\"\u003eV–: 3, 6, 7, 8\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2013\" data-end=\"2065\"\u003e\n\u003cp data-start=\"2015\" data-end=\"2031\"\u003e\u003cstrong data-start=\"2015\" data-end=\"2029\"\u003ePorts 3–8:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2036\" data-end=\"2065\"\u003e\n\u003cli data-start=\"2036\" data-end=\"2048\"\u003e\n\u003cp data-start=\"2038\" data-end=\"2048\"\u003eV+: 1, 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2053\" data-end=\"2065\"\u003e\n\u003cp data-start=\"2055\" data-end=\"2065\"\u003eV–: 3, 6\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2066\" data-end=\"2096\"\u003e\n\u003cp data-start=\"2068\" data-end=\"2096\"\u003e\u003cstrong data-start=\"2068\" data-end=\"2090\"\u003eLong-Distance PoE:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2098\" data-end=\"2101\"\u003e\n\u003ch2 data-start=\"2103\" data-end=\"2123\"\u003eHardware Features\u003c\/h2\u003e\n\u003ch3 data-start=\"2124\" data-end=\"2148\"\u003eDIP Switch Functions\u003c\/h3\u003e\n\u003cul data-start=\"2149\" data-end=\"2563\"\u003e\n\u003cli data-start=\"2149\" data-end=\"2243\"\u003e\n\u003cp data-start=\"2151\" data-end=\"2170\"\u003e\u003cstrong data-start=\"2151\" data-end=\"2168\"\u003eManaged Mode:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2173\" data-end=\"2243\"\u003e\n\u003cli data-start=\"2173\" data-end=\"2219\"\u003e\n\u003cp data-start=\"2175\" data-end=\"2219\"\u003eON (default): Local web + cloud management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2222\" data-end=\"2243\"\u003e\n\u003cp data-start=\"2224\" data-end=\"2243\"\u003eOFF: Unmanaged mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2244\" data-end=\"2406\"\u003e\n\u003cp data-start=\"2246\" data-end=\"2265\"\u003e\u003cstrong data-start=\"2246\" data-end=\"2263\"\u003ePoE Watchdog:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2268\" data-end=\"2406\"\u003e\n\u003cli data-start=\"2268\" data-end=\"2290\"\u003e\n\u003cp data-start=\"2270\" data-end=\"2290\"\u003eMonitors ports 1–8\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2293\" data-end=\"2363\"\u003e\n\u003cp data-start=\"2295\" data-end=\"2363\"\u003eAutomatically restarts PoE if no traffic is detected for 2 minutes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2366\" data-end=\"2406\"\u003e\n\u003cp data-start=\"2368\" data-end=\"2406\"\u003e\u003cem data-start=\"2368\" data-end=\"2406\"\u003eOnly active when Managed Mode is OFF\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2407\" data-end=\"2538\"\u003e\n\u003cp data-start=\"2409\" data-end=\"2427\"\u003e\u003cstrong data-start=\"2409\" data-end=\"2425\"\u003eExtend Mode:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2430\" data-end=\"2538\"\u003e\n\u003cli data-start=\"2430\" data-end=\"2495\"\u003e\n\u003cp data-start=\"2432\" data-end=\"2495\"\u003ePorts 1–8 support up to \u003cstrong data-start=\"2456\" data-end=\"2465\"\u003e250 m\u003c\/strong\u003e transmission at \u003cstrong data-start=\"2482\" data-end=\"2493\"\u003e10 Mbps\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2498\" data-end=\"2538\"\u003e\n\u003cp data-start=\"2500\" data-end=\"2538\"\u003e\u003cem data-start=\"2500\" data-end=\"2538\"\u003eOnly active when Managed Mode is OFF\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2540\" data-end=\"2563\"\u003e\n\u003cp data-start=\"2542\" data-end=\"2563\"\u003e\u003cstrong data-start=\"2542\" data-end=\"2559\"\u003eReset Button:\u003c\/strong\u003e 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2565\" data-end=\"2568\"\u003e\n\u003ch2 data-start=\"2570\" data-end=\"2584\"\u003ePerformance\u003c\/h2\u003e\n\u003cul data-start=\"2585\" data-end=\"2736\"\u003e\n\u003cli data-start=\"2585\" data-end=\"2614\"\u003e\n\u003cp data-start=\"2587\" data-end=\"2614\"\u003e\u003cstrong data-start=\"2587\" data-end=\"2596\"\u003eMTBF:\u003c\/strong\u003e 2,482,955 hours\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2615\" data-end=\"2644\"\u003e\n\u003cp data-start=\"2617\" data-end=\"2644\"\u003e\u003cstrong data-start=\"2617\" data-end=\"2635\"\u003ePacket Buffer:\u003c\/strong\u003e 4 Mbit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2645\" data-end=\"2678\"\u003e\n\u003cp data-start=\"2647\" data-end=\"2678\"\u003e\u003cstrong data-start=\"2647\" data-end=\"2663\"\u003eJumbo Frame:\u003c\/strong\u003e 15,360 Bytes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2679\" data-end=\"2708\"\u003e\n\u003cp data-start=\"2681\" data-end=\"2708\"\u003e\u003cstrong data-start=\"2681\" data-end=\"2703\"\u003eMAC Address Table:\u003c\/strong\u003e 8K\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2709\" data-end=\"2736\"\u003e\n\u003cp data-start=\"2711\" data-end=\"2736\"\u003e\u003cstrong data-start=\"2711\" data-end=\"2731\"\u003eSupported VLANs:\u003c\/strong\u003e 32\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2738\" data-end=\"2741\"\u003e\n\u003ch2 data-start=\"2743\" data-end=\"2763\"\u003eNetwork Standards\u003c\/h2\u003e\n\u003cul data-start=\"2764\" data-end=\"2897\"\u003e\n\u003cli data-start=\"2764\" data-end=\"2897\"\u003e\n\u003cp data-start=\"2766\" data-end=\"2787\"\u003e\u003cstrong data-start=\"2766\" data-end=\"2785\"\u003eIEEE Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2790\" data-end=\"2897\"\u003e\n\u003cli data-start=\"2790\" data-end=\"2804\"\u003e\n\u003cp data-start=\"2792\" data-end=\"2804\"\u003eIEEE 802.3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2807\" data-end=\"2822\"\u003e\n\u003cp data-start=\"2809\" data-end=\"2822\"\u003eIEEE 802.3u\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2825\" data-end=\"2840\"\u003e\n\u003cp data-start=\"2827\" data-end=\"2840\"\u003eIEEE 802.3x\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2843\" data-end=\"2859\"\u003e\n\u003cp data-start=\"2845\" data-end=\"2859\"\u003eIEEE 802.3ab\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2862\" data-end=\"2878\"\u003e\n\u003cp data-start=\"2864\" data-end=\"2878\"\u003eIEEE 802.3az\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2881\" data-end=\"2897\"\u003e\n\u003cp data-start=\"2883\" data-end=\"2897\"\u003eIEEE 802.3ad\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2899\" data-end=\"2902\"\u003e\n\u003ch2 data-start=\"2904\" data-end=\"2923\"\u003eNetwork Features\u003c\/h2\u003e\n\u003cul data-start=\"2924\" data-end=\"3394\"\u003e\n\u003cli data-start=\"2924\" data-end=\"2967\"\u003e\n\u003cp data-start=\"2926\" data-end=\"2967\"\u003e\u003cstrong data-start=\"2926\" data-end=\"2955\"\u003eEthernet Loop Protection:\u003c\/strong\u003e STP, RSTP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2968\" data-end=\"2998\"\u003e\n\u003cp data-start=\"2970\" data-end=\"2998\"\u003e\u003cstrong data-start=\"2970\" data-end=\"2979\"\u003eVLAN:\u003c\/strong\u003e IEEE 802.1Q VLAN\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2999\" data-end=\"3043\"\u003e\n\u003cp data-start=\"3001\" data-end=\"3043\"\u003e\u003cstrong data-start=\"3001\" data-end=\"3022\"\u003eLink Aggregation:\u003c\/strong\u003e Static aggregation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3044\" data-end=\"3238\"\u003e\n\u003cp data-start=\"3046\" data-end=\"3066\"\u003e\u003cstrong data-start=\"3046\" data-end=\"3064\"\u003ePort Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3069\" data-end=\"3238\"\u003e\n\u003cli data-start=\"3069\" data-end=\"3097\"\u003e\n\u003cp data-start=\"3071\" data-end=\"3097\"\u003eIEEE 802.3x Flow Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3100\" data-end=\"3131\"\u003e\n\u003cp data-start=\"3102\" data-end=\"3131\"\u003eUnknown Unicast Suppression\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3134\" data-end=\"3161\"\u003e\n\u003cp data-start=\"3136\" data-end=\"3161\"\u003eMulticast Storm Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3164\" data-end=\"3191\"\u003e\n\u003cp data-start=\"3166\" data-end=\"3191\"\u003eBroadcast Storm Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3194\" data-end=\"3216\"\u003e\n\u003cp data-start=\"3196\" data-end=\"3216\"\u003eMAC + Port Binding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3219\" data-end=\"3238\"\u003e\n\u003cp data-start=\"3221\" data-end=\"3238\"\u003eLoop Prevention\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3239\" data-end=\"3309\"\u003e\n\u003cp data-start=\"3241\" data-end=\"3262\"\u003e\u003cstrong data-start=\"3241\" data-end=\"3260\"\u003ePort Mirroring:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3265\" data-end=\"3309\"\u003e\n\u003cli data-start=\"3265\" data-end=\"3289\"\u003e\n\u003cp data-start=\"3267\" data-end=\"3289\"\u003eLocal Port Mirroring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3292\" data-end=\"3309\"\u003e\n\u003cp data-start=\"3294\" data-end=\"3309\"\u003eN:1 Mirroring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3310\" data-end=\"3335\"\u003e\n\u003cp data-start=\"3312\" data-end=\"3335\"\u003e\u003cstrong data-start=\"3312\" data-end=\"3329\"\u003eLLDP Support:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3336\" data-end=\"3361\"\u003e\n\u003cp data-start=\"3338\" data-end=\"3361\"\u003e\u003cstrong data-start=\"3338\" data-end=\"3347\"\u003eDHCP:\u003c\/strong\u003e DHCP Client\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3362\" data-end=\"3394\"\u003e\n\u003cp data-start=\"3364\" data-end=\"3394\"\u003e\u003cstrong data-start=\"3364\" data-end=\"3377\"\u003eSecurity:\u003c\/strong\u003e Port Isolation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3396\" data-end=\"3399\"\u003e\n\u003ch2 data-start=\"3401\" data-end=\"3414\"\u003eManagement\u003c\/h2\u003e\n\u003cul data-start=\"3415\" data-end=\"3550\"\u003e\n\u003cli data-start=\"3415\" data-end=\"3486\"\u003e\n\u003cp data-start=\"3417\" data-end=\"3442\"\u003e\u003cstrong data-start=\"3417\" data-end=\"3440\"\u003eManagement Methods:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3445\" data-end=\"3486\"\u003e\n\u003cli data-start=\"3445\" data-end=\"3463\"\u003e\n\u003cp data-start=\"3447\" data-end=\"3463\"\u003eWeb Management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3466\" data-end=\"3486\"\u003e\n\u003cp data-start=\"3468\" data-end=\"3486\"\u003eCloud Management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3487\" data-end=\"3550\"\u003e\n\u003cp data-start=\"3489\" data-end=\"3520\"\u003e\u003cstrong data-start=\"3489\" data-end=\"3518\"\u003eMonitoring \u0026amp; Maintenance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3523\" data-end=\"3550\"\u003e\n\u003cli data-start=\"3523\" data-end=\"3531\"\u003e\n\u003cp data-start=\"3525\" data-end=\"3531\"\u003eLogs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3534\" data-end=\"3550\"\u003e\n\u003cp data-start=\"3536\" data-end=\"3550\"\u003eFault Alarms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3552\" data-end=\"3555\"\u003e\n\u003ch2 data-start=\"3557\" data-end=\"3570\"\u003eProtection\u003c\/h2\u003e\n\u003cul data-start=\"3571\" data-end=\"3734\"\u003e\n\u003cli data-start=\"3571\" data-end=\"3650\"\u003e\n\u003cp data-start=\"3573\" data-end=\"3594\"\u003e\u003cstrong data-start=\"3573\" data-end=\"3592\"\u003eESD Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3597\" data-end=\"3650\"\u003e\n\u003cli data-start=\"3597\" data-end=\"3620\"\u003e\n\u003cp data-start=\"3599\" data-end=\"3620\"\u003eAir Discharge: 8 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3623\" data-end=\"3650\"\u003e\n\u003cp data-start=\"3625\" data-end=\"3650\"\u003eContact Discharge: 6 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3651\" data-end=\"3734\"\u003e\n\u003cp data-start=\"3653\" data-end=\"3680\"\u003e\u003cstrong data-start=\"3653\" data-end=\"3678\"\u003eLightning Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3683\" data-end=\"3734\"\u003e\n\u003cli data-start=\"3683\" data-end=\"3704\"\u003e\n\u003cp data-start=\"3685\" data-end=\"3704\"\u003eCommon Mode: 6 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3707\" data-end=\"3734\"\u003e\n\u003cp data-start=\"3709\" data-end=\"3734\"\u003eDifferential Mode: 1 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3736\" data-end=\"3739\"\u003e\n\u003ch2 data-start=\"3741\" data-end=\"3767\"\u003ePhysical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"3768\" data-end=\"4041\"\u003e\n\u003cli data-start=\"3768\" data-end=\"3805\"\u003e\n\u003cp data-start=\"3770\" data-end=\"3805\"\u003e\u003cstrong data-start=\"3770\" data-end=\"3785\"\u003eNet Weight:\u003c\/strong\u003e 0.36 kg (0.79 lb)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3806\" data-end=\"3845\"\u003e\n\u003cp data-start=\"3808\" data-end=\"3845\"\u003e\u003cstrong data-start=\"3808\" data-end=\"3825\"\u003eGross Weight:\u003c\/strong\u003e 1.13 kg (2.49 lb)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3846\" data-end=\"3925\"\u003e\n\u003cp data-start=\"3848\" data-end=\"3873\"\u003e\u003cstrong data-start=\"3848\" data-end=\"3871\"\u003eProduct Dimensions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3876\" data-end=\"3925\"\u003e\n\u003cli data-start=\"3876\" data-end=\"3925\"\u003e\n\u003cp data-start=\"3878\" data-end=\"3925\"\u003e184.6 × 103.3 × 27 mm (7.27\" × 4.07\" × 1.06\")\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3926\" data-end=\"4004\"\u003e\n\u003cp data-start=\"3928\" data-end=\"3955\"\u003e\u003cstrong data-start=\"3928\" data-end=\"3953\"\u003ePackaging Dimensions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3958\" data-end=\"4004\"\u003e\n\u003cli data-start=\"3958\" data-end=\"4004\"\u003e\n\u003cp data-start=\"3960\" data-end=\"4004\"\u003e252 × 137 × 113 mm (9.92\" × 5.39\" × 4.45\")\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4005\" data-end=\"4041\"\u003e\n\u003cp data-start=\"4007\" data-end=\"4041\"\u003e\u003cstrong data-start=\"4007\" data-end=\"4027\"\u003eCasing Material:\u003c\/strong\u003e Sheet metal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4043\" data-end=\"4046\"\u003e\n\u003ch2 data-start=\"4048\" data-end=\"4063\"\u003eInstallation\u003c\/h2\u003e\n\u003cul data-start=\"4064\" data-end=\"4115\"\u003e\n\u003cli data-start=\"4064\" data-end=\"4115\"\u003e\n\u003cp data-start=\"4066\" data-end=\"4115\"\u003e\u003cstrong data-start=\"4066\" data-end=\"4087\"\u003eMounting Options:\u003c\/strong\u003e Desktop mount, Wall mount\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4117\" data-end=\"4120\"\u003e\n\u003ch2 data-start=\"4122\" data-end=\"4139\"\u003eCertifications\u003c\/h2\u003e\n\u003cul data-start=\"4140\" data-end=\"4148\"\u003e\n\u003cli data-start=\"4140\" data-end=\"4148\"\u003e\n\u003cp data-start=\"4142\" data-end=\"4148\"\u003e\u003cstrong data-start=\"4142\" data-end=\"4148\"\u003eCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4150\" data-end=\"4153\"\u003e\n\u003ch2 data-start=\"4155\" data-end=\"4170\"\u003ePacking List\u003c\/h2\u003e\n\u003cul data-start=\"4171\" data-end=\"4272\"\u003e\n\u003cli data-start=\"4171\" data-end=\"4190\"\u003e\n\u003cp data-start=\"4173\" data-end=\"4190\"\u003e1 × User Manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4191\" data-end=\"4231\"\u003e\n\u003cp data-start=\"4193\" data-end=\"4231\"\u003e1 × Legal and Regulatory Information\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4232\" data-end=\"4253\"\u003e\n\u003cp data-start=\"4234\" data-end=\"4253\"\u003e1 × Power Adapter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4254\" data-end=\"4272\"\u003e\n\u003cp data-start=\"4256\" data-end=\"4272\"\u003e1 × Power Cord\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 3 Year Dahua ANZ Manufacturer Warranty\u003c\/p\u003e","published_at":"2026-04-15T12:20:03+10:00","created_at":"2026-04-15T12:20:05+10:00","vendor":"Dahua","type":"Dahua PoE Switch","tags":["Australian Warranty","brand-Dahua","CCTV","Dahua","Dahua PoE Switch","DH-CS4010-8GT-110","Network Switch","PoE","PoE Switch","Security","Security Camera","Tekcart","type-Switch"],"price":23256,"price_min":23256,"price_max":23256,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":43221619703897,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"DH-CS4010-8GT-110","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Dahua CS4010-8GT-110 10-Port Cloud Managed Desktop Gigabit Switch with 8-Port POE","public_title":null,"options":["Default Title"],"price":23256,"weight":0,"compare_at_price":null,"inventory_management":"shopify","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/tekcart.com.au\/cdn\/shop\/files\/CS4010-8GT-110.png?v=1776219605"],"featured_image":"\/\/tekcart.com.au\/cdn\/shop\/files\/CS4010-8GT-110.png?v=1776219605","options":["Title"],"media":[{"alt":null,"id":28080822911065,"position":1,"preview_image":{"aspect_ratio":1.531,"height":1092,"width":1672,"src":"\/\/tekcart.com.au\/cdn\/shop\/files\/CS4010-8GT-110.png?v=1776219605"},"aspect_ratio":1.531,"height":1092,"media_type":"image","src":"\/\/tekcart.com.au\/cdn\/shop\/files\/CS4010-8GT-110.png?v=1776219605","width":1672}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch2 data-start=\"153\" data-end=\"220\"\u003e10-Port Cloud Managed Desktop \u003cstrong data-start=\"186\" data-end=\"197\"\u003eGigabit\u003c\/strong\u003e Switch with 8-Port PoE\u003c\/h2\u003e\n\u003ch3 data-start=\"222\" data-end=\"238\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"239\" data-end=\"804\"\u003e\n\u003cli data-start=\"239\" data-end=\"308\"\u003e\n\u003cp data-start=\"241\" data-end=\"308\"\u003e\u003cstrong data-start=\"241\" data-end=\"272\"\u003e8 × RJ-45 Gigabit PoE ports\u003c\/strong\u003e, \u003cstrong data-start=\"274\" data-end=\"308\"\u003e2 × RJ-45 Gigabit uplink ports\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"309\" data-end=\"432\"\u003e\n\u003cp data-start=\"311\" data-end=\"339\"\u003e\u003cstrong data-start=\"311\" data-end=\"337\"\u003e110 W total PoE budget\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"342\" data-end=\"432\"\u003e\n\u003cli data-start=\"342\" data-end=\"378\"\u003e\n\u003cp data-start=\"344\" data-end=\"378\"\u003eIEEE 802.3af\/at on all PoE ports\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"381\" data-end=\"432\"\u003e\n\u003cp data-start=\"383\" data-end=\"432\"\u003e\u003cstrong data-start=\"383\" data-end=\"432\"\u003eIEEE 802.3bt support on Ports 1–2 (red ports)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"433\" data-end=\"552\"\u003e\n\u003cp data-start=\"435\" data-end=\"474\"\u003e\u003cstrong data-start=\"435\" data-end=\"449\"\u003eDIP switch\u003c\/strong\u003e for fast mode switching:\u003c\/p\u003e\n\u003cul data-start=\"477\" data-end=\"552\"\u003e\n\u003cli data-start=\"477\" data-end=\"511\"\u003e\n\u003cp data-start=\"479\" data-end=\"511\"\u003eCloud-Managed \/ Unmanaged Mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"514\" data-end=\"530\"\u003e\n\u003cp data-start=\"516\" data-end=\"530\"\u003ePoE Watchdog\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"533\" data-end=\"552\"\u003e\n\u003cp data-start=\"535\" data-end=\"552\"\u003eLong-Distance PoE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"553\" data-end=\"603\"\u003e\n\u003cp data-start=\"555\" data-end=\"603\"\u003e\u003cstrong data-start=\"555\" data-end=\"586\"\u003eWide operating temperature:\u003c\/strong\u003e –10 °C to +55 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"604\" data-end=\"660\"\u003e\n\u003cp data-start=\"606\" data-end=\"660\"\u003eSupports \u003cstrong data-start=\"615\" data-end=\"634\"\u003eVLAN, STP, RSTP\u003c\/strong\u003e, and \u003cstrong data-start=\"640\" data-end=\"660\"\u003elink aggregation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"661\" data-end=\"734\"\u003e\n\u003cp data-start=\"663\" data-end=\"734\"\u003e\u003cstrong data-start=\"663\" data-end=\"678\"\u003eWeb-managed\u003c\/strong\u003e and \u003cstrong data-start=\"683\" data-end=\"715\"\u003ecentralised cloud management\u003c\/strong\u003e via \u003cstrong data-start=\"720\" data-end=\"734\"\u003eDoLynk App\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"735\" data-end=\"804\"\u003e\n\u003cp data-start=\"737\" data-end=\"804\"\u003eEasy configuration with \u003cstrong data-start=\"761\" data-end=\"804\"\u003eauto network detection and system setup\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"735\" data-end=\"804\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0047\/9510\/5391\/files\/DH-CS4010-8GT-110_V2_datasheet_20251104.pdf?v=1765923577\"\u003e\u003cstrong data-start=\"761\" data-end=\"804\"\u003eDatasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"806\" data-end=\"809\"\u003e\n\u003ch2 data-start=\"811\" data-end=\"834\"\u003eBasic Specifications\u003c\/h2\u003e\n\u003cul data-start=\"835\" data-end=\"946\"\u003e\n\u003cli data-start=\"835\" data-end=\"867\"\u003e\n\u003cp data-start=\"837\" data-end=\"867\"\u003e\u003cstrong data-start=\"837\" data-end=\"857\"\u003eSwitching Layer:\u003c\/strong\u003e Layer 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"868\" data-end=\"903\"\u003e\n\u003cp data-start=\"870\" data-end=\"903\"\u003e\u003cstrong data-start=\"870\" data-end=\"893\"\u003eSwitching Capacity:\u003c\/strong\u003e 20 Gbps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"904\" data-end=\"946\"\u003e\n\u003cp data-start=\"906\" data-end=\"946\"\u003e\u003cstrong data-start=\"906\" data-end=\"933\"\u003ePacket Forwarding Rate:\u003c\/strong\u003e 14.88 Mpps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"948\" data-end=\"951\"\u003e\n\u003ch2 data-start=\"953\" data-end=\"974\"\u003ePort Configuration\u003c\/h2\u003e\n\u003cul data-start=\"975\" data-end=\"1090\"\u003e\n\u003cli data-start=\"975\" data-end=\"1026\"\u003e\n\u003cp data-start=\"977\" data-end=\"1026\"\u003e\u003cstrong data-start=\"977\" data-end=\"991\"\u003ePorts 1–8:\u003c\/strong\u003e 8 × RJ-45 10\/100\/1000 Mbps (PoE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1027\" data-end=\"1090\"\u003e\n\u003cp data-start=\"1029\" data-end=\"1090\"\u003e\u003cstrong data-start=\"1029\" data-end=\"1044\"\u003ePorts 9–10:\u003c\/strong\u003e 2 × RJ-45 10\/100\/1000 Mbps (Gigabit uplink)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1092\" data-end=\"1095\"\u003e\n\u003ch2 data-start=\"1097\" data-end=\"1128\"\u003eEnvironmental Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1129\" data-end=\"1371\"\u003e\n\u003cli data-start=\"1129\" data-end=\"1196\"\u003e\n\u003cp data-start=\"1131\" data-end=\"1196\"\u003e\u003cstrong data-start=\"1131\" data-end=\"1157\"\u003eOperating Temperature:\u003c\/strong\u003e –10 °C to +55 °C (+14 °F to +131 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1197\" data-end=\"1252\"\u003e\n\u003cp data-start=\"1199\" data-end=\"1252\"\u003e\u003cstrong data-start=\"1199\" data-end=\"1222\"\u003eOperating Humidity:\u003c\/strong\u003e 10%–90% RH (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1253\" data-end=\"1318\"\u003e\n\u003cp data-start=\"1255\" data-end=\"1318\"\u003e\u003cstrong data-start=\"1255\" data-end=\"1279\"\u003eStorage Temperature:\u003c\/strong\u003e –40 °C to +75 °C (–40 °F to +167 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1319\" data-end=\"1371\"\u003e\n\u003cp data-start=\"1321\" data-end=\"1371\"\u003e\u003cstrong data-start=\"1321\" data-end=\"1342\"\u003eStorage Humidity:\u003c\/strong\u003e 5%–95% RH (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1373\" data-end=\"1376\"\u003e\n\u003ch2 data-start=\"1378\" data-end=\"1386\"\u003ePower\u003c\/h2\u003e\n\u003cul data-start=\"1387\" data-end=\"1516\"\u003e\n\u003cli data-start=\"1387\" data-end=\"1448\"\u003e\n\u003cp data-start=\"1389\" data-end=\"1448\"\u003e\u003cstrong data-start=\"1389\" data-end=\"1406\"\u003ePower Supply:\u003c\/strong\u003e External power adapter, 54 VDC \/ 2.22 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1449\" data-end=\"1516\"\u003e\n\u003cp data-start=\"1451\" data-end=\"1475\"\u003e\u003cstrong data-start=\"1451\" data-end=\"1473\"\u003ePower Consumption:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1478\" data-end=\"1516\"\u003e\n\u003cli data-start=\"1478\" data-end=\"1493\"\u003e\n\u003cp data-start=\"1480\" data-end=\"1493\"\u003eIdle: 5.7 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1496\" data-end=\"1516\"\u003e\n\u003cp data-start=\"1498\" data-end=\"1516\"\u003eFull Load: 115 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1518\" data-end=\"1521\"\u003e\n\u003ch2 data-start=\"1523\" data-end=\"1544\"\u003ePoE Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1545\" data-end=\"2096\"\u003e\n\u003cli data-start=\"1545\" data-end=\"1569\"\u003e\n\u003cp data-start=\"1547\" data-end=\"1569\"\u003e\u003cstrong data-start=\"1547\" data-end=\"1563\"\u003ePoE Support:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1570\" data-end=\"1644\"\u003e\n\u003cp data-start=\"1572\" data-end=\"1644\"\u003e\u003cstrong data-start=\"1572\" data-end=\"1590\"\u003ePoE Protocols:\u003c\/strong\u003e IEEE 802.3af \/ IEEE 802.3at \/ Hi-PoE \/ IEEE 802.3bt\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1645\" data-end=\"1772\"\u003e\n\u003cp data-start=\"1647\" data-end=\"1670\"\u003e\u003cstrong data-start=\"1647\" data-end=\"1668\"\u003ePoE Output Power:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1673\" data-end=\"1772\"\u003e\n\u003cli data-start=\"1673\" data-end=\"1703\"\u003e\n\u003cp data-start=\"1675\" data-end=\"1703\"\u003ePorts 1–2: ≤ 90 W per port\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1706\" data-end=\"1736\"\u003e\n\u003cp data-start=\"1708\" data-end=\"1736\"\u003ePorts 3–8: ≤ 30 W per port\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1739\" data-end=\"1772\"\u003e\n\u003cp data-start=\"1741\" data-end=\"1772\"\u003e\u003cstrong data-start=\"1741\" data-end=\"1762\"\u003eTotal PoE Budget:\u003c\/strong\u003e ≤ 110 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1773\" data-end=\"1915\"\u003e\n\u003cp data-start=\"1775\" data-end=\"1802\"\u003e\u003cstrong data-start=\"1775\" data-end=\"1800\"\u003ePoE Power Management:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1805\" data-end=\"1915\"\u003e\n\u003cli data-start=\"1805\" data-end=\"1841\"\u003e\n\u003cp data-start=\"1807\" data-end=\"1841\"\u003ePoE power consumption management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1844\" data-end=\"1864\"\u003e\n\u003cp data-start=\"1846\" data-end=\"1864\"\u003ePoE power on\/off\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1867\" data-end=\"1915\"\u003e\n\u003cp data-start=\"1869\" data-end=\"1915\"\u003eAutomatic PoE shutdown on overload detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1916\" data-end=\"2065\"\u003e\n\u003cp data-start=\"1918\" data-end=\"1943\"\u003e\u003cstrong data-start=\"1918\" data-end=\"1941\"\u003ePoE Pin Assignment:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1946\" data-end=\"2065\"\u003e\n\u003cli data-start=\"1946\" data-end=\"2010\"\u003e\n\u003cp data-start=\"1948\" data-end=\"1964\"\u003e\u003cstrong data-start=\"1948\" data-end=\"1962\"\u003ePorts 1–2:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1969\" data-end=\"2010\"\u003e\n\u003cli data-start=\"1969\" data-end=\"1987\"\u003e\n\u003cp data-start=\"1971\" data-end=\"1987\"\u003eV+: 1, 2, 4, 5\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1992\" data-end=\"2010\"\u003e\n\u003cp data-start=\"1994\" data-end=\"2010\"\u003eV–: 3, 6, 7, 8\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2013\" data-end=\"2065\"\u003e\n\u003cp data-start=\"2015\" data-end=\"2031\"\u003e\u003cstrong data-start=\"2015\" data-end=\"2029\"\u003ePorts 3–8:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2036\" data-end=\"2065\"\u003e\n\u003cli data-start=\"2036\" data-end=\"2048\"\u003e\n\u003cp data-start=\"2038\" data-end=\"2048\"\u003eV+: 1, 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2053\" data-end=\"2065\"\u003e\n\u003cp data-start=\"2055\" data-end=\"2065\"\u003eV–: 3, 6\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2066\" data-end=\"2096\"\u003e\n\u003cp data-start=\"2068\" data-end=\"2096\"\u003e\u003cstrong data-start=\"2068\" data-end=\"2090\"\u003eLong-Distance PoE:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2098\" data-end=\"2101\"\u003e\n\u003ch2 data-start=\"2103\" data-end=\"2123\"\u003eHardware Features\u003c\/h2\u003e\n\u003ch3 data-start=\"2124\" data-end=\"2148\"\u003eDIP Switch Functions\u003c\/h3\u003e\n\u003cul data-start=\"2149\" data-end=\"2563\"\u003e\n\u003cli data-start=\"2149\" data-end=\"2243\"\u003e\n\u003cp data-start=\"2151\" data-end=\"2170\"\u003e\u003cstrong data-start=\"2151\" data-end=\"2168\"\u003eManaged Mode:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2173\" data-end=\"2243\"\u003e\n\u003cli data-start=\"2173\" data-end=\"2219\"\u003e\n\u003cp data-start=\"2175\" data-end=\"2219\"\u003eON (default): Local web + cloud management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2222\" data-end=\"2243\"\u003e\n\u003cp data-start=\"2224\" data-end=\"2243\"\u003eOFF: Unmanaged mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2244\" data-end=\"2406\"\u003e\n\u003cp data-start=\"2246\" data-end=\"2265\"\u003e\u003cstrong data-start=\"2246\" data-end=\"2263\"\u003ePoE Watchdog:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2268\" data-end=\"2406\"\u003e\n\u003cli data-start=\"2268\" data-end=\"2290\"\u003e\n\u003cp data-start=\"2270\" data-end=\"2290\"\u003eMonitors ports 1–8\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2293\" data-end=\"2363\"\u003e\n\u003cp data-start=\"2295\" data-end=\"2363\"\u003eAutomatically restarts PoE if no traffic is detected for 2 minutes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2366\" data-end=\"2406\"\u003e\n\u003cp data-start=\"2368\" data-end=\"2406\"\u003e\u003cem data-start=\"2368\" data-end=\"2406\"\u003eOnly active when Managed Mode is OFF\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2407\" data-end=\"2538\"\u003e\n\u003cp data-start=\"2409\" data-end=\"2427\"\u003e\u003cstrong data-start=\"2409\" data-end=\"2425\"\u003eExtend Mode:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2430\" data-end=\"2538\"\u003e\n\u003cli data-start=\"2430\" data-end=\"2495\"\u003e\n\u003cp data-start=\"2432\" data-end=\"2495\"\u003ePorts 1–8 support up to \u003cstrong data-start=\"2456\" data-end=\"2465\"\u003e250 m\u003c\/strong\u003e transmission at \u003cstrong data-start=\"2482\" data-end=\"2493\"\u003e10 Mbps\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2498\" data-end=\"2538\"\u003e\n\u003cp data-start=\"2500\" data-end=\"2538\"\u003e\u003cem data-start=\"2500\" data-end=\"2538\"\u003eOnly active when Managed Mode is OFF\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2540\" data-end=\"2563\"\u003e\n\u003cp data-start=\"2542\" data-end=\"2563\"\u003e\u003cstrong data-start=\"2542\" data-end=\"2559\"\u003eReset Button:\u003c\/strong\u003e 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2565\" data-end=\"2568\"\u003e\n\u003ch2 data-start=\"2570\" data-end=\"2584\"\u003ePerformance\u003c\/h2\u003e\n\u003cul data-start=\"2585\" data-end=\"2736\"\u003e\n\u003cli data-start=\"2585\" data-end=\"2614\"\u003e\n\u003cp data-start=\"2587\" data-end=\"2614\"\u003e\u003cstrong data-start=\"2587\" data-end=\"2596\"\u003eMTBF:\u003c\/strong\u003e 2,482,955 hours\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2615\" data-end=\"2644\"\u003e\n\u003cp data-start=\"2617\" data-end=\"2644\"\u003e\u003cstrong data-start=\"2617\" data-end=\"2635\"\u003ePacket Buffer:\u003c\/strong\u003e 4 Mbit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2645\" data-end=\"2678\"\u003e\n\u003cp data-start=\"2647\" data-end=\"2678\"\u003e\u003cstrong data-start=\"2647\" data-end=\"2663\"\u003eJumbo Frame:\u003c\/strong\u003e 15,360 Bytes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2679\" data-end=\"2708\"\u003e\n\u003cp data-start=\"2681\" data-end=\"2708\"\u003e\u003cstrong data-start=\"2681\" data-end=\"2703\"\u003eMAC Address Table:\u003c\/strong\u003e 8K\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2709\" data-end=\"2736\"\u003e\n\u003cp data-start=\"2711\" data-end=\"2736\"\u003e\u003cstrong data-start=\"2711\" data-end=\"2731\"\u003eSupported VLANs:\u003c\/strong\u003e 32\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2738\" data-end=\"2741\"\u003e\n\u003ch2 data-start=\"2743\" data-end=\"2763\"\u003eNetwork Standards\u003c\/h2\u003e\n\u003cul data-start=\"2764\" data-end=\"2897\"\u003e\n\u003cli data-start=\"2764\" data-end=\"2897\"\u003e\n\u003cp data-start=\"2766\" data-end=\"2787\"\u003e\u003cstrong data-start=\"2766\" data-end=\"2785\"\u003eIEEE Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2790\" data-end=\"2897\"\u003e\n\u003cli data-start=\"2790\" data-end=\"2804\"\u003e\n\u003cp data-start=\"2792\" data-end=\"2804\"\u003eIEEE 802.3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2807\" data-end=\"2822\"\u003e\n\u003cp data-start=\"2809\" data-end=\"2822\"\u003eIEEE 802.3u\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2825\" data-end=\"2840\"\u003e\n\u003cp data-start=\"2827\" data-end=\"2840\"\u003eIEEE 802.3x\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2843\" data-end=\"2859\"\u003e\n\u003cp data-start=\"2845\" data-end=\"2859\"\u003eIEEE 802.3ab\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2862\" data-end=\"2878\"\u003e\n\u003cp data-start=\"2864\" data-end=\"2878\"\u003eIEEE 802.3az\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2881\" data-end=\"2897\"\u003e\n\u003cp data-start=\"2883\" data-end=\"2897\"\u003eIEEE 802.3ad\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2899\" data-end=\"2902\"\u003e\n\u003ch2 data-start=\"2904\" data-end=\"2923\"\u003eNetwork Features\u003c\/h2\u003e\n\u003cul data-start=\"2924\" data-end=\"3394\"\u003e\n\u003cli data-start=\"2924\" data-end=\"2967\"\u003e\n\u003cp data-start=\"2926\" data-end=\"2967\"\u003e\u003cstrong data-start=\"2926\" data-end=\"2955\"\u003eEthernet Loop Protection:\u003c\/strong\u003e STP, RSTP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2968\" data-end=\"2998\"\u003e\n\u003cp data-start=\"2970\" data-end=\"2998\"\u003e\u003cstrong data-start=\"2970\" data-end=\"2979\"\u003eVLAN:\u003c\/strong\u003e IEEE 802.1Q VLAN\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2999\" data-end=\"3043\"\u003e\n\u003cp data-start=\"3001\" data-end=\"3043\"\u003e\u003cstrong data-start=\"3001\" data-end=\"3022\"\u003eLink Aggregation:\u003c\/strong\u003e Static aggregation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3044\" data-end=\"3238\"\u003e\n\u003cp data-start=\"3046\" data-end=\"3066\"\u003e\u003cstrong data-start=\"3046\" data-end=\"3064\"\u003ePort Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3069\" data-end=\"3238\"\u003e\n\u003cli data-start=\"3069\" data-end=\"3097\"\u003e\n\u003cp data-start=\"3071\" data-end=\"3097\"\u003eIEEE 802.3x Flow Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3100\" data-end=\"3131\"\u003e\n\u003cp data-start=\"3102\" data-end=\"3131\"\u003eUnknown Unicast Suppression\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3134\" data-end=\"3161\"\u003e\n\u003cp data-start=\"3136\" data-end=\"3161\"\u003eMulticast Storm Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3164\" data-end=\"3191\"\u003e\n\u003cp data-start=\"3166\" data-end=\"3191\"\u003eBroadcast Storm Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3194\" data-end=\"3216\"\u003e\n\u003cp data-start=\"3196\" data-end=\"3216\"\u003eMAC + Port Binding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3219\" data-end=\"3238\"\u003e\n\u003cp data-start=\"3221\" data-end=\"3238\"\u003eLoop Prevention\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3239\" data-end=\"3309\"\u003e\n\u003cp data-start=\"3241\" data-end=\"3262\"\u003e\u003cstrong data-start=\"3241\" data-end=\"3260\"\u003ePort Mirroring:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3265\" data-end=\"3309\"\u003e\n\u003cli data-start=\"3265\" data-end=\"3289\"\u003e\n\u003cp data-start=\"3267\" data-end=\"3289\"\u003eLocal Port Mirroring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3292\" data-end=\"3309\"\u003e\n\u003cp data-start=\"3294\" data-end=\"3309\"\u003eN:1 Mirroring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3310\" data-end=\"3335\"\u003e\n\u003cp data-start=\"3312\" data-end=\"3335\"\u003e\u003cstrong data-start=\"3312\" data-end=\"3329\"\u003eLLDP Support:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3336\" data-end=\"3361\"\u003e\n\u003cp data-start=\"3338\" data-end=\"3361\"\u003e\u003cstrong data-start=\"3338\" data-end=\"3347\"\u003eDHCP:\u003c\/strong\u003e DHCP Client\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3362\" data-end=\"3394\"\u003e\n\u003cp data-start=\"3364\" data-end=\"3394\"\u003e\u003cstrong data-start=\"3364\" data-end=\"3377\"\u003eSecurity:\u003c\/strong\u003e Port Isolation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3396\" data-end=\"3399\"\u003e\n\u003ch2 data-start=\"3401\" data-end=\"3414\"\u003eManagement\u003c\/h2\u003e\n\u003cul data-start=\"3415\" data-end=\"3550\"\u003e\n\u003cli data-start=\"3415\" data-end=\"3486\"\u003e\n\u003cp data-start=\"3417\" data-end=\"3442\"\u003e\u003cstrong data-start=\"3417\" data-end=\"3440\"\u003eManagement Methods:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3445\" data-end=\"3486\"\u003e\n\u003cli data-start=\"3445\" data-end=\"3463\"\u003e\n\u003cp data-start=\"3447\" data-end=\"3463\"\u003eWeb Management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3466\" data-end=\"3486\"\u003e\n\u003cp data-start=\"3468\" data-end=\"3486\"\u003eCloud Management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3487\" data-end=\"3550\"\u003e\n\u003cp data-start=\"3489\" data-end=\"3520\"\u003e\u003cstrong data-start=\"3489\" data-end=\"3518\"\u003eMonitoring \u0026amp; Maintenance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3523\" data-end=\"3550\"\u003e\n\u003cli data-start=\"3523\" data-end=\"3531\"\u003e\n\u003cp data-start=\"3525\" data-end=\"3531\"\u003eLogs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3534\" data-end=\"3550\"\u003e\n\u003cp data-start=\"3536\" data-end=\"3550\"\u003eFault Alarms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3552\" data-end=\"3555\"\u003e\n\u003ch2 data-start=\"3557\" data-end=\"3570\"\u003eProtection\u003c\/h2\u003e\n\u003cul data-start=\"3571\" data-end=\"3734\"\u003e\n\u003cli data-start=\"3571\" data-end=\"3650\"\u003e\n\u003cp data-start=\"3573\" data-end=\"3594\"\u003e\u003cstrong data-start=\"3573\" data-end=\"3592\"\u003eESD Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3597\" data-end=\"3650\"\u003e\n\u003cli data-start=\"3597\" data-end=\"3620\"\u003e\n\u003cp data-start=\"3599\" data-end=\"3620\"\u003eAir Discharge: 8 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3623\" data-end=\"3650\"\u003e\n\u003cp data-start=\"3625\" data-end=\"3650\"\u003eContact Discharge: 6 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3651\" data-end=\"3734\"\u003e\n\u003cp data-start=\"3653\" data-end=\"3680\"\u003e\u003cstrong data-start=\"3653\" data-end=\"3678\"\u003eLightning Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3683\" data-end=\"3734\"\u003e\n\u003cli data-start=\"3683\" data-end=\"3704\"\u003e\n\u003cp data-start=\"3685\" data-end=\"3704\"\u003eCommon Mode: 6 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3707\" data-end=\"3734\"\u003e\n\u003cp data-start=\"3709\" data-end=\"3734\"\u003eDifferential Mode: 1 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3736\" data-end=\"3739\"\u003e\n\u003ch2 data-start=\"3741\" data-end=\"3767\"\u003ePhysical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"3768\" data-end=\"4041\"\u003e\n\u003cli data-start=\"3768\" data-end=\"3805\"\u003e\n\u003cp data-start=\"3770\" data-end=\"3805\"\u003e\u003cstrong data-start=\"3770\" data-end=\"3785\"\u003eNet Weight:\u003c\/strong\u003e 0.36 kg (0.79 lb)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3806\" data-end=\"3845\"\u003e\n\u003cp data-start=\"3808\" data-end=\"3845\"\u003e\u003cstrong data-start=\"3808\" data-end=\"3825\"\u003eGross Weight:\u003c\/strong\u003e 1.13 kg (2.49 lb)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3846\" data-end=\"3925\"\u003e\n\u003cp data-start=\"3848\" data-end=\"3873\"\u003e\u003cstrong data-start=\"3848\" data-end=\"3871\"\u003eProduct Dimensions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3876\" data-end=\"3925\"\u003e\n\u003cli data-start=\"3876\" data-end=\"3925\"\u003e\n\u003cp data-start=\"3878\" data-end=\"3925\"\u003e184.6 × 103.3 × 27 mm (7.27\" × 4.07\" × 1.06\")\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3926\" data-end=\"4004\"\u003e\n\u003cp data-start=\"3928\" data-end=\"3955\"\u003e\u003cstrong data-start=\"3928\" data-end=\"3953\"\u003ePackaging Dimensions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3958\" data-end=\"4004\"\u003e\n\u003cli data-start=\"3958\" data-end=\"4004\"\u003e\n\u003cp data-start=\"3960\" data-end=\"4004\"\u003e252 × 137 × 113 mm (9.92\" × 5.39\" × 4.45\")\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4005\" data-end=\"4041\"\u003e\n\u003cp data-start=\"4007\" data-end=\"4041\"\u003e\u003cstrong data-start=\"4007\" data-end=\"4027\"\u003eCasing Material:\u003c\/strong\u003e Sheet metal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4043\" data-end=\"4046\"\u003e\n\u003ch2 data-start=\"4048\" data-end=\"4063\"\u003eInstallation\u003c\/h2\u003e\n\u003cul data-start=\"4064\" data-end=\"4115\"\u003e\n\u003cli data-start=\"4064\" data-end=\"4115\"\u003e\n\u003cp data-start=\"4066\" data-end=\"4115\"\u003e\u003cstrong data-start=\"4066\" data-end=\"4087\"\u003eMounting Options:\u003c\/strong\u003e Desktop mount, Wall mount\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4117\" data-end=\"4120\"\u003e\n\u003ch2 data-start=\"4122\" data-end=\"4139\"\u003eCertifications\u003c\/h2\u003e\n\u003cul data-start=\"4140\" data-end=\"4148\"\u003e\n\u003cli data-start=\"4140\" data-end=\"4148\"\u003e\n\u003cp data-start=\"4142\" data-end=\"4148\"\u003e\u003cstrong data-start=\"4142\" data-end=\"4148\"\u003eCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4150\" data-end=\"4153\"\u003e\n\u003ch2 data-start=\"4155\" data-end=\"4170\"\u003ePacking List\u003c\/h2\u003e\n\u003cul data-start=\"4171\" data-end=\"4272\"\u003e\n\u003cli data-start=\"4171\" data-end=\"4190\"\u003e\n\u003cp data-start=\"4173\" data-end=\"4190\"\u003e1 × User Manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4191\" data-end=\"4231\"\u003e\n\u003cp data-start=\"4193\" data-end=\"4231\"\u003e1 × Legal and Regulatory Information\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4232\" data-end=\"4253\"\u003e\n\u003cp data-start=\"4234\" data-end=\"4253\"\u003e1 × Power Adapter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4254\" data-end=\"4272\"\u003e\n\u003cp data-start=\"4256\" data-end=\"4272\"\u003e1 × Power Cord\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 3 Year Dahua ANZ Manufacturer Warranty\u003c\/p\u003e"}
Translation missing: en.products.product.regular_price $249.00 -
-
{"id":8191822069849,"title":"Dahua CS4010-8GT-110 10-Port Cloud Managed Desktop Gigabit Switch with 8-Port POE","handle":"cs4010-8gt-110-dahua-10-port-cloud-managed-desktop-gigabit-switch-with-8-port-poe","description":"\u003ch2 data-start=\"153\" data-end=\"220\"\u003e10-Port Cloud Managed Desktop \u003cstrong data-start=\"186\" data-end=\"197\"\u003eGigabit\u003c\/strong\u003e Switch with 8-Port PoE\u003c\/h2\u003e\n\u003ch3 data-start=\"222\" data-end=\"238\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"239\" data-end=\"804\"\u003e\n\u003cli data-start=\"239\" data-end=\"308\"\u003e\n\u003cp data-start=\"241\" data-end=\"308\"\u003e\u003cstrong data-start=\"241\" data-end=\"272\"\u003e8 × RJ-45 Gigabit PoE ports\u003c\/strong\u003e, \u003cstrong data-start=\"274\" data-end=\"308\"\u003e2 × RJ-45 Gigabit uplink ports\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"309\" data-end=\"432\"\u003e\n\u003cp data-start=\"311\" data-end=\"339\"\u003e\u003cstrong data-start=\"311\" data-end=\"337\"\u003e110 W total PoE budget\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"342\" data-end=\"432\"\u003e\n\u003cli data-start=\"342\" data-end=\"378\"\u003e\n\u003cp data-start=\"344\" data-end=\"378\"\u003eIEEE 802.3af\/at on all PoE ports\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"381\" data-end=\"432\"\u003e\n\u003cp data-start=\"383\" data-end=\"432\"\u003e\u003cstrong data-start=\"383\" data-end=\"432\"\u003eIEEE 802.3bt support on Ports 1–2 (red ports)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"433\" data-end=\"552\"\u003e\n\u003cp data-start=\"435\" data-end=\"474\"\u003e\u003cstrong data-start=\"435\" data-end=\"449\"\u003eDIP switch\u003c\/strong\u003e for fast mode switching:\u003c\/p\u003e\n\u003cul data-start=\"477\" data-end=\"552\"\u003e\n\u003cli data-start=\"477\" data-end=\"511\"\u003e\n\u003cp data-start=\"479\" data-end=\"511\"\u003eCloud-Managed \/ Unmanaged Mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"514\" data-end=\"530\"\u003e\n\u003cp data-start=\"516\" data-end=\"530\"\u003ePoE Watchdog\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"533\" data-end=\"552\"\u003e\n\u003cp data-start=\"535\" data-end=\"552\"\u003eLong-Distance PoE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"553\" data-end=\"603\"\u003e\n\u003cp data-start=\"555\" data-end=\"603\"\u003e\u003cstrong data-start=\"555\" data-end=\"586\"\u003eWide operating temperature:\u003c\/strong\u003e –10 °C to +55 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"604\" data-end=\"660\"\u003e\n\u003cp data-start=\"606\" data-end=\"660\"\u003eSupports \u003cstrong data-start=\"615\" data-end=\"634\"\u003eVLAN, STP, RSTP\u003c\/strong\u003e, and \u003cstrong data-start=\"640\" data-end=\"660\"\u003elink aggregation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"661\" data-end=\"734\"\u003e\n\u003cp data-start=\"663\" data-end=\"734\"\u003e\u003cstrong data-start=\"663\" data-end=\"678\"\u003eWeb-managed\u003c\/strong\u003e and \u003cstrong data-start=\"683\" data-end=\"715\"\u003ecentralised cloud management\u003c\/strong\u003e via \u003cstrong data-start=\"720\" data-end=\"734\"\u003eDoLynk App\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"735\" data-end=\"804\"\u003e\n\u003cp data-start=\"737\" data-end=\"804\"\u003eEasy configuration with \u003cstrong data-start=\"761\" data-end=\"804\"\u003eauto network detection and system setup\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"735\" data-end=\"804\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0047\/9510\/5391\/files\/DH-CS4010-8GT-110_V2_datasheet_20251104.pdf?v=1765923577\"\u003e\u003cstrong data-start=\"761\" data-end=\"804\"\u003eDatasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"806\" data-end=\"809\"\u003e\n\u003ch2 data-start=\"811\" data-end=\"834\"\u003eBasic Specifications\u003c\/h2\u003e\n\u003cul data-start=\"835\" data-end=\"946\"\u003e\n\u003cli data-start=\"835\" data-end=\"867\"\u003e\n\u003cp data-start=\"837\" data-end=\"867\"\u003e\u003cstrong data-start=\"837\" data-end=\"857\"\u003eSwitching Layer:\u003c\/strong\u003e Layer 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"868\" data-end=\"903\"\u003e\n\u003cp data-start=\"870\" data-end=\"903\"\u003e\u003cstrong data-start=\"870\" data-end=\"893\"\u003eSwitching Capacity:\u003c\/strong\u003e 20 Gbps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"904\" data-end=\"946\"\u003e\n\u003cp data-start=\"906\" data-end=\"946\"\u003e\u003cstrong data-start=\"906\" data-end=\"933\"\u003ePacket Forwarding Rate:\u003c\/strong\u003e 14.88 Mpps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"948\" data-end=\"951\"\u003e\n\u003ch2 data-start=\"953\" data-end=\"974\"\u003ePort Configuration\u003c\/h2\u003e\n\u003cul data-start=\"975\" data-end=\"1090\"\u003e\n\u003cli data-start=\"975\" data-end=\"1026\"\u003e\n\u003cp data-start=\"977\" data-end=\"1026\"\u003e\u003cstrong data-start=\"977\" data-end=\"991\"\u003ePorts 1–8:\u003c\/strong\u003e 8 × RJ-45 10\/100\/1000 Mbps (PoE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1027\" data-end=\"1090\"\u003e\n\u003cp data-start=\"1029\" data-end=\"1090\"\u003e\u003cstrong data-start=\"1029\" data-end=\"1044\"\u003ePorts 9–10:\u003c\/strong\u003e 2 × RJ-45 10\/100\/1000 Mbps (Gigabit uplink)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1092\" data-end=\"1095\"\u003e\n\u003ch2 data-start=\"1097\" data-end=\"1128\"\u003eEnvironmental Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1129\" data-end=\"1371\"\u003e\n\u003cli data-start=\"1129\" data-end=\"1196\"\u003e\n\u003cp data-start=\"1131\" data-end=\"1196\"\u003e\u003cstrong data-start=\"1131\" data-end=\"1157\"\u003eOperating Temperature:\u003c\/strong\u003e –10 °C to +55 °C (+14 °F to +131 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1197\" data-end=\"1252\"\u003e\n\u003cp data-start=\"1199\" data-end=\"1252\"\u003e\u003cstrong data-start=\"1199\" data-end=\"1222\"\u003eOperating Humidity:\u003c\/strong\u003e 10%–90% RH (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1253\" data-end=\"1318\"\u003e\n\u003cp data-start=\"1255\" data-end=\"1318\"\u003e\u003cstrong data-start=\"1255\" data-end=\"1279\"\u003eStorage Temperature:\u003c\/strong\u003e –40 °C to +75 °C (–40 °F to +167 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1319\" data-end=\"1371\"\u003e\n\u003cp data-start=\"1321\" data-end=\"1371\"\u003e\u003cstrong data-start=\"1321\" data-end=\"1342\"\u003eStorage Humidity:\u003c\/strong\u003e 5%–95% RH (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1373\" data-end=\"1376\"\u003e\n\u003ch2 data-start=\"1378\" data-end=\"1386\"\u003ePower\u003c\/h2\u003e\n\u003cul data-start=\"1387\" data-end=\"1516\"\u003e\n\u003cli data-start=\"1387\" data-end=\"1448\"\u003e\n\u003cp data-start=\"1389\" data-end=\"1448\"\u003e\u003cstrong data-start=\"1389\" data-end=\"1406\"\u003ePower Supply:\u003c\/strong\u003e External power adapter, 54 VDC \/ 2.22 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1449\" data-end=\"1516\"\u003e\n\u003cp data-start=\"1451\" data-end=\"1475\"\u003e\u003cstrong data-start=\"1451\" data-end=\"1473\"\u003ePower Consumption:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1478\" data-end=\"1516\"\u003e\n\u003cli data-start=\"1478\" data-end=\"1493\"\u003e\n\u003cp data-start=\"1480\" data-end=\"1493\"\u003eIdle: 5.7 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1496\" data-end=\"1516\"\u003e\n\u003cp data-start=\"1498\" data-end=\"1516\"\u003eFull Load: 115 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1518\" data-end=\"1521\"\u003e\n\u003ch2 data-start=\"1523\" data-end=\"1544\"\u003ePoE Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1545\" data-end=\"2096\"\u003e\n\u003cli data-start=\"1545\" data-end=\"1569\"\u003e\n\u003cp data-start=\"1547\" data-end=\"1569\"\u003e\u003cstrong data-start=\"1547\" data-end=\"1563\"\u003ePoE Support:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1570\" data-end=\"1644\"\u003e\n\u003cp data-start=\"1572\" data-end=\"1644\"\u003e\u003cstrong data-start=\"1572\" data-end=\"1590\"\u003ePoE Protocols:\u003c\/strong\u003e IEEE 802.3af \/ IEEE 802.3at \/ Hi-PoE \/ IEEE 802.3bt\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1645\" data-end=\"1772\"\u003e\n\u003cp data-start=\"1647\" data-end=\"1670\"\u003e\u003cstrong data-start=\"1647\" data-end=\"1668\"\u003ePoE Output Power:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1673\" data-end=\"1772\"\u003e\n\u003cli data-start=\"1673\" data-end=\"1703\"\u003e\n\u003cp data-start=\"1675\" data-end=\"1703\"\u003ePorts 1–2: ≤ 90 W per port\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1706\" data-end=\"1736\"\u003e\n\u003cp data-start=\"1708\" data-end=\"1736\"\u003ePorts 3–8: ≤ 30 W per port\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1739\" data-end=\"1772\"\u003e\n\u003cp data-start=\"1741\" data-end=\"1772\"\u003e\u003cstrong data-start=\"1741\" data-end=\"1762\"\u003eTotal PoE Budget:\u003c\/strong\u003e ≤ 110 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1773\" data-end=\"1915\"\u003e\n\u003cp data-start=\"1775\" data-end=\"1802\"\u003e\u003cstrong data-start=\"1775\" data-end=\"1800\"\u003ePoE Power Management:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1805\" data-end=\"1915\"\u003e\n\u003cli data-start=\"1805\" data-end=\"1841\"\u003e\n\u003cp data-start=\"1807\" data-end=\"1841\"\u003ePoE power consumption management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1844\" data-end=\"1864\"\u003e\n\u003cp data-start=\"1846\" data-end=\"1864\"\u003ePoE power on\/off\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1867\" data-end=\"1915\"\u003e\n\u003cp data-start=\"1869\" data-end=\"1915\"\u003eAutomatic PoE shutdown on overload detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1916\" data-end=\"2065\"\u003e\n\u003cp data-start=\"1918\" data-end=\"1943\"\u003e\u003cstrong data-start=\"1918\" data-end=\"1941\"\u003ePoE Pin Assignment:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1946\" data-end=\"2065\"\u003e\n\u003cli data-start=\"1946\" data-end=\"2010\"\u003e\n\u003cp data-start=\"1948\" data-end=\"1964\"\u003e\u003cstrong data-start=\"1948\" data-end=\"1962\"\u003ePorts 1–2:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1969\" data-end=\"2010\"\u003e\n\u003cli data-start=\"1969\" data-end=\"1987\"\u003e\n\u003cp data-start=\"1971\" data-end=\"1987\"\u003eV+: 1, 2, 4, 5\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1992\" data-end=\"2010\"\u003e\n\u003cp data-start=\"1994\" data-end=\"2010\"\u003eV–: 3, 6, 7, 8\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2013\" data-end=\"2065\"\u003e\n\u003cp data-start=\"2015\" data-end=\"2031\"\u003e\u003cstrong data-start=\"2015\" data-end=\"2029\"\u003ePorts 3–8:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2036\" data-end=\"2065\"\u003e\n\u003cli data-start=\"2036\" data-end=\"2048\"\u003e\n\u003cp data-start=\"2038\" data-end=\"2048\"\u003eV+: 1, 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2053\" data-end=\"2065\"\u003e\n\u003cp data-start=\"2055\" data-end=\"2065\"\u003eV–: 3, 6\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2066\" data-end=\"2096\"\u003e\n\u003cp data-start=\"2068\" data-end=\"2096\"\u003e\u003cstrong data-start=\"2068\" data-end=\"2090\"\u003eLong-Distance PoE:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2098\" data-end=\"2101\"\u003e\n\u003ch2 data-start=\"2103\" data-end=\"2123\"\u003eHardware Features\u003c\/h2\u003e\n\u003ch3 data-start=\"2124\" data-end=\"2148\"\u003eDIP Switch Functions\u003c\/h3\u003e\n\u003cul data-start=\"2149\" data-end=\"2563\"\u003e\n\u003cli data-start=\"2149\" data-end=\"2243\"\u003e\n\u003cp data-start=\"2151\" data-end=\"2170\"\u003e\u003cstrong data-start=\"2151\" data-end=\"2168\"\u003eManaged Mode:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2173\" data-end=\"2243\"\u003e\n\u003cli data-start=\"2173\" data-end=\"2219\"\u003e\n\u003cp data-start=\"2175\" data-end=\"2219\"\u003eON (default): Local web + cloud management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2222\" data-end=\"2243\"\u003e\n\u003cp data-start=\"2224\" data-end=\"2243\"\u003eOFF: Unmanaged mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2244\" data-end=\"2406\"\u003e\n\u003cp data-start=\"2246\" data-end=\"2265\"\u003e\u003cstrong data-start=\"2246\" data-end=\"2263\"\u003ePoE Watchdog:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2268\" data-end=\"2406\"\u003e\n\u003cli data-start=\"2268\" data-end=\"2290\"\u003e\n\u003cp data-start=\"2270\" data-end=\"2290\"\u003eMonitors ports 1–8\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2293\" data-end=\"2363\"\u003e\n\u003cp data-start=\"2295\" data-end=\"2363\"\u003eAutomatically restarts PoE if no traffic is detected for 2 minutes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2366\" data-end=\"2406\"\u003e\n\u003cp data-start=\"2368\" data-end=\"2406\"\u003e\u003cem data-start=\"2368\" data-end=\"2406\"\u003eOnly active when Managed Mode is OFF\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2407\" data-end=\"2538\"\u003e\n\u003cp data-start=\"2409\" data-end=\"2427\"\u003e\u003cstrong data-start=\"2409\" data-end=\"2425\"\u003eExtend Mode:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2430\" data-end=\"2538\"\u003e\n\u003cli data-start=\"2430\" data-end=\"2495\"\u003e\n\u003cp data-start=\"2432\" data-end=\"2495\"\u003ePorts 1–8 support up to \u003cstrong data-start=\"2456\" data-end=\"2465\"\u003e250 m\u003c\/strong\u003e transmission at \u003cstrong data-start=\"2482\" data-end=\"2493\"\u003e10 Mbps\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2498\" data-end=\"2538\"\u003e\n\u003cp data-start=\"2500\" data-end=\"2538\"\u003e\u003cem data-start=\"2500\" data-end=\"2538\"\u003eOnly active when Managed Mode is OFF\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2540\" data-end=\"2563\"\u003e\n\u003cp data-start=\"2542\" data-end=\"2563\"\u003e\u003cstrong data-start=\"2542\" data-end=\"2559\"\u003eReset Button:\u003c\/strong\u003e 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2565\" data-end=\"2568\"\u003e\n\u003ch2 data-start=\"2570\" data-end=\"2584\"\u003ePerformance\u003c\/h2\u003e\n\u003cul data-start=\"2585\" data-end=\"2736\"\u003e\n\u003cli data-start=\"2585\" data-end=\"2614\"\u003e\n\u003cp data-start=\"2587\" data-end=\"2614\"\u003e\u003cstrong data-start=\"2587\" data-end=\"2596\"\u003eMTBF:\u003c\/strong\u003e 2,482,955 hours\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2615\" data-end=\"2644\"\u003e\n\u003cp data-start=\"2617\" data-end=\"2644\"\u003e\u003cstrong data-start=\"2617\" data-end=\"2635\"\u003ePacket Buffer:\u003c\/strong\u003e 4 Mbit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2645\" data-end=\"2678\"\u003e\n\u003cp data-start=\"2647\" data-end=\"2678\"\u003e\u003cstrong data-start=\"2647\" data-end=\"2663\"\u003eJumbo Frame:\u003c\/strong\u003e 15,360 Bytes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2679\" data-end=\"2708\"\u003e\n\u003cp data-start=\"2681\" data-end=\"2708\"\u003e\u003cstrong data-start=\"2681\" data-end=\"2703\"\u003eMAC Address Table:\u003c\/strong\u003e 8K\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2709\" data-end=\"2736\"\u003e\n\u003cp data-start=\"2711\" data-end=\"2736\"\u003e\u003cstrong data-start=\"2711\" data-end=\"2731\"\u003eSupported VLANs:\u003c\/strong\u003e 32\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2738\" data-end=\"2741\"\u003e\n\u003ch2 data-start=\"2743\" data-end=\"2763\"\u003eNetwork Standards\u003c\/h2\u003e\n\u003cul data-start=\"2764\" data-end=\"2897\"\u003e\n\u003cli data-start=\"2764\" data-end=\"2897\"\u003e\n\u003cp data-start=\"2766\" data-end=\"2787\"\u003e\u003cstrong data-start=\"2766\" data-end=\"2785\"\u003eIEEE Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2790\" data-end=\"2897\"\u003e\n\u003cli data-start=\"2790\" data-end=\"2804\"\u003e\n\u003cp data-start=\"2792\" data-end=\"2804\"\u003eIEEE 802.3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2807\" data-end=\"2822\"\u003e\n\u003cp data-start=\"2809\" data-end=\"2822\"\u003eIEEE 802.3u\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2825\" data-end=\"2840\"\u003e\n\u003cp data-start=\"2827\" data-end=\"2840\"\u003eIEEE 802.3x\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2843\" data-end=\"2859\"\u003e\n\u003cp data-start=\"2845\" data-end=\"2859\"\u003eIEEE 802.3ab\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2862\" data-end=\"2878\"\u003e\n\u003cp data-start=\"2864\" data-end=\"2878\"\u003eIEEE 802.3az\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2881\" data-end=\"2897\"\u003e\n\u003cp data-start=\"2883\" data-end=\"2897\"\u003eIEEE 802.3ad\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2899\" data-end=\"2902\"\u003e\n\u003ch2 data-start=\"2904\" data-end=\"2923\"\u003eNetwork Features\u003c\/h2\u003e\n\u003cul data-start=\"2924\" data-end=\"3394\"\u003e\n\u003cli data-start=\"2924\" data-end=\"2967\"\u003e\n\u003cp data-start=\"2926\" data-end=\"2967\"\u003e\u003cstrong data-start=\"2926\" data-end=\"2955\"\u003eEthernet Loop Protection:\u003c\/strong\u003e STP, RSTP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2968\" data-end=\"2998\"\u003e\n\u003cp data-start=\"2970\" data-end=\"2998\"\u003e\u003cstrong data-start=\"2970\" data-end=\"2979\"\u003eVLAN:\u003c\/strong\u003e IEEE 802.1Q VLAN\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2999\" data-end=\"3043\"\u003e\n\u003cp data-start=\"3001\" data-end=\"3043\"\u003e\u003cstrong data-start=\"3001\" data-end=\"3022\"\u003eLink Aggregation:\u003c\/strong\u003e Static aggregation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3044\" data-end=\"3238\"\u003e\n\u003cp data-start=\"3046\" data-end=\"3066\"\u003e\u003cstrong data-start=\"3046\" data-end=\"3064\"\u003ePort Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3069\" data-end=\"3238\"\u003e\n\u003cli data-start=\"3069\" data-end=\"3097\"\u003e\n\u003cp data-start=\"3071\" data-end=\"3097\"\u003eIEEE 802.3x Flow Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3100\" data-end=\"3131\"\u003e\n\u003cp data-start=\"3102\" data-end=\"3131\"\u003eUnknown Unicast Suppression\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3134\" data-end=\"3161\"\u003e\n\u003cp data-start=\"3136\" data-end=\"3161\"\u003eMulticast Storm Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3164\" data-end=\"3191\"\u003e\n\u003cp data-start=\"3166\" data-end=\"3191\"\u003eBroadcast Storm Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3194\" data-end=\"3216\"\u003e\n\u003cp data-start=\"3196\" data-end=\"3216\"\u003eMAC + Port Binding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3219\" data-end=\"3238\"\u003e\n\u003cp data-start=\"3221\" data-end=\"3238\"\u003eLoop Prevention\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3239\" data-end=\"3309\"\u003e\n\u003cp data-start=\"3241\" data-end=\"3262\"\u003e\u003cstrong data-start=\"3241\" data-end=\"3260\"\u003ePort Mirroring:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3265\" data-end=\"3309\"\u003e\n\u003cli data-start=\"3265\" data-end=\"3289\"\u003e\n\u003cp data-start=\"3267\" data-end=\"3289\"\u003eLocal Port Mirroring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3292\" data-end=\"3309\"\u003e\n\u003cp data-start=\"3294\" data-end=\"3309\"\u003eN:1 Mirroring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3310\" data-end=\"3335\"\u003e\n\u003cp data-start=\"3312\" data-end=\"3335\"\u003e\u003cstrong data-start=\"3312\" data-end=\"3329\"\u003eLLDP Support:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3336\" data-end=\"3361\"\u003e\n\u003cp data-start=\"3338\" data-end=\"3361\"\u003e\u003cstrong data-start=\"3338\" data-end=\"3347\"\u003eDHCP:\u003c\/strong\u003e DHCP Client\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3362\" data-end=\"3394\"\u003e\n\u003cp data-start=\"3364\" data-end=\"3394\"\u003e\u003cstrong data-start=\"3364\" data-end=\"3377\"\u003eSecurity:\u003c\/strong\u003e Port Isolation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3396\" data-end=\"3399\"\u003e\n\u003ch2 data-start=\"3401\" data-end=\"3414\"\u003eManagement\u003c\/h2\u003e\n\u003cul data-start=\"3415\" data-end=\"3550\"\u003e\n\u003cli data-start=\"3415\" data-end=\"3486\"\u003e\n\u003cp data-start=\"3417\" data-end=\"3442\"\u003e\u003cstrong data-start=\"3417\" data-end=\"3440\"\u003eManagement Methods:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3445\" data-end=\"3486\"\u003e\n\u003cli data-start=\"3445\" data-end=\"3463\"\u003e\n\u003cp data-start=\"3447\" data-end=\"3463\"\u003eWeb Management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3466\" data-end=\"3486\"\u003e\n\u003cp data-start=\"3468\" data-end=\"3486\"\u003eCloud Management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3487\" data-end=\"3550\"\u003e\n\u003cp data-start=\"3489\" data-end=\"3520\"\u003e\u003cstrong data-start=\"3489\" data-end=\"3518\"\u003eMonitoring \u0026amp; Maintenance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3523\" data-end=\"3550\"\u003e\n\u003cli data-start=\"3523\" data-end=\"3531\"\u003e\n\u003cp data-start=\"3525\" data-end=\"3531\"\u003eLogs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3534\" data-end=\"3550\"\u003e\n\u003cp data-start=\"3536\" data-end=\"3550\"\u003eFault Alarms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3552\" data-end=\"3555\"\u003e\n\u003ch2 data-start=\"3557\" data-end=\"3570\"\u003eProtection\u003c\/h2\u003e\n\u003cul data-start=\"3571\" data-end=\"3734\"\u003e\n\u003cli data-start=\"3571\" data-end=\"3650\"\u003e\n\u003cp data-start=\"3573\" data-end=\"3594\"\u003e\u003cstrong data-start=\"3573\" data-end=\"3592\"\u003eESD Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3597\" data-end=\"3650\"\u003e\n\u003cli data-start=\"3597\" data-end=\"3620\"\u003e\n\u003cp data-start=\"3599\" data-end=\"3620\"\u003eAir Discharge: 8 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3623\" data-end=\"3650\"\u003e\n\u003cp data-start=\"3625\" data-end=\"3650\"\u003eContact Discharge: 6 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3651\" data-end=\"3734\"\u003e\n\u003cp data-start=\"3653\" data-end=\"3680\"\u003e\u003cstrong data-start=\"3653\" data-end=\"3678\"\u003eLightning Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3683\" data-end=\"3734\"\u003e\n\u003cli data-start=\"3683\" data-end=\"3704\"\u003e\n\u003cp data-start=\"3685\" data-end=\"3704\"\u003eCommon Mode: 6 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3707\" data-end=\"3734\"\u003e\n\u003cp data-start=\"3709\" data-end=\"3734\"\u003eDifferential Mode: 1 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3736\" data-end=\"3739\"\u003e\n\u003ch2 data-start=\"3741\" data-end=\"3767\"\u003ePhysical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"3768\" data-end=\"4041\"\u003e\n\u003cli data-start=\"3768\" data-end=\"3805\"\u003e\n\u003cp data-start=\"3770\" data-end=\"3805\"\u003e\u003cstrong data-start=\"3770\" data-end=\"3785\"\u003eNet Weight:\u003c\/strong\u003e 0.36 kg (0.79 lb)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3806\" data-end=\"3845\"\u003e\n\u003cp data-start=\"3808\" data-end=\"3845\"\u003e\u003cstrong data-start=\"3808\" data-end=\"3825\"\u003eGross Weight:\u003c\/strong\u003e 1.13 kg (2.49 lb)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3846\" data-end=\"3925\"\u003e\n\u003cp data-start=\"3848\" data-end=\"3873\"\u003e\u003cstrong data-start=\"3848\" data-end=\"3871\"\u003eProduct Dimensions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3876\" data-end=\"3925\"\u003e\n\u003cli data-start=\"3876\" data-end=\"3925\"\u003e\n\u003cp data-start=\"3878\" data-end=\"3925\"\u003e184.6 × 103.3 × 27 mm (7.27\" × 4.07\" × 1.06\")\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3926\" data-end=\"4004\"\u003e\n\u003cp data-start=\"3928\" data-end=\"3955\"\u003e\u003cstrong data-start=\"3928\" data-end=\"3953\"\u003ePackaging Dimensions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3958\" data-end=\"4004\"\u003e\n\u003cli data-start=\"3958\" data-end=\"4004\"\u003e\n\u003cp data-start=\"3960\" data-end=\"4004\"\u003e252 × 137 × 113 mm (9.92\" × 5.39\" × 4.45\")\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4005\" data-end=\"4041\"\u003e\n\u003cp data-start=\"4007\" data-end=\"4041\"\u003e\u003cstrong data-start=\"4007\" data-end=\"4027\"\u003eCasing Material:\u003c\/strong\u003e Sheet metal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4043\" data-end=\"4046\"\u003e\n\u003ch2 data-start=\"4048\" data-end=\"4063\"\u003eInstallation\u003c\/h2\u003e\n\u003cul data-start=\"4064\" data-end=\"4115\"\u003e\n\u003cli data-start=\"4064\" data-end=\"4115\"\u003e\n\u003cp data-start=\"4066\" data-end=\"4115\"\u003e\u003cstrong data-start=\"4066\" data-end=\"4087\"\u003eMounting Options:\u003c\/strong\u003e Desktop mount, Wall mount\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4117\" data-end=\"4120\"\u003e\n\u003ch2 data-start=\"4122\" data-end=\"4139\"\u003eCertifications\u003c\/h2\u003e\n\u003cul data-start=\"4140\" data-end=\"4148\"\u003e\n\u003cli data-start=\"4140\" data-end=\"4148\"\u003e\n\u003cp data-start=\"4142\" data-end=\"4148\"\u003e\u003cstrong data-start=\"4142\" data-end=\"4148\"\u003eCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4150\" data-end=\"4153\"\u003e\n\u003ch2 data-start=\"4155\" data-end=\"4170\"\u003ePacking List\u003c\/h2\u003e\n\u003cul data-start=\"4171\" data-end=\"4272\"\u003e\n\u003cli data-start=\"4171\" data-end=\"4190\"\u003e\n\u003cp data-start=\"4173\" data-end=\"4190\"\u003e1 × User Manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4191\" data-end=\"4231\"\u003e\n\u003cp data-start=\"4193\" data-end=\"4231\"\u003e1 × Legal and Regulatory Information\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4232\" data-end=\"4253\"\u003e\n\u003cp data-start=\"4234\" data-end=\"4253\"\u003e1 × Power Adapter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4254\" data-end=\"4272\"\u003e\n\u003cp data-start=\"4256\" data-end=\"4272\"\u003e1 × Power Cord\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 3 Year Dahua ANZ Manufacturer Warranty\u003c\/p\u003e","published_at":"2026-04-15T12:20:03+10:00","created_at":"2026-04-15T12:20:05+10:00","vendor":"Dahua","type":"Dahua PoE Switch","tags":["Australian Warranty","brand-Dahua","CCTV","Dahua","Dahua PoE Switch","DH-CS4010-8GT-110","Network Switch","PoE","PoE Switch","Security","Security Camera","Tekcart","type-Switch"],"price":23256,"price_min":23256,"price_max":23256,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":43221619703897,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"DH-CS4010-8GT-110","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Dahua CS4010-8GT-110 10-Port Cloud Managed Desktop Gigabit Switch with 8-Port POE","public_title":null,"options":["Default Title"],"price":23256,"weight":0,"compare_at_price":null,"inventory_management":"shopify","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/tekcart.com.au\/cdn\/shop\/files\/CS4010-8GT-110.png?v=1776219605"],"featured_image":"\/\/tekcart.com.au\/cdn\/shop\/files\/CS4010-8GT-110.png?v=1776219605","options":["Title"],"media":[{"alt":null,"id":28080822911065,"position":1,"preview_image":{"aspect_ratio":1.531,"height":1092,"width":1672,"src":"\/\/tekcart.com.au\/cdn\/shop\/files\/CS4010-8GT-110.png?v=1776219605"},"aspect_ratio":1.531,"height":1092,"media_type":"image","src":"\/\/tekcart.com.au\/cdn\/shop\/files\/CS4010-8GT-110.png?v=1776219605","width":1672}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch2 data-start=\"153\" data-end=\"220\"\u003e10-Port Cloud Managed Desktop \u003cstrong data-start=\"186\" data-end=\"197\"\u003eGigabit\u003c\/strong\u003e Switch with 8-Port PoE\u003c\/h2\u003e\n\u003ch3 data-start=\"222\" data-end=\"238\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"239\" data-end=\"804\"\u003e\n\u003cli data-start=\"239\" data-end=\"308\"\u003e\n\u003cp data-start=\"241\" data-end=\"308\"\u003e\u003cstrong data-start=\"241\" data-end=\"272\"\u003e8 × RJ-45 Gigabit PoE ports\u003c\/strong\u003e, \u003cstrong data-start=\"274\" data-end=\"308\"\u003e2 × RJ-45 Gigabit uplink ports\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"309\" data-end=\"432\"\u003e\n\u003cp data-start=\"311\" data-end=\"339\"\u003e\u003cstrong data-start=\"311\" data-end=\"337\"\u003e110 W total PoE budget\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"342\" data-end=\"432\"\u003e\n\u003cli data-start=\"342\" data-end=\"378\"\u003e\n\u003cp data-start=\"344\" data-end=\"378\"\u003eIEEE 802.3af\/at on all PoE ports\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"381\" data-end=\"432\"\u003e\n\u003cp data-start=\"383\" data-end=\"432\"\u003e\u003cstrong data-start=\"383\" data-end=\"432\"\u003eIEEE 802.3bt support on Ports 1–2 (red ports)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"433\" data-end=\"552\"\u003e\n\u003cp data-start=\"435\" data-end=\"474\"\u003e\u003cstrong data-start=\"435\" data-end=\"449\"\u003eDIP switch\u003c\/strong\u003e for fast mode switching:\u003c\/p\u003e\n\u003cul data-start=\"477\" data-end=\"552\"\u003e\n\u003cli data-start=\"477\" data-end=\"511\"\u003e\n\u003cp data-start=\"479\" data-end=\"511\"\u003eCloud-Managed \/ Unmanaged Mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"514\" data-end=\"530\"\u003e\n\u003cp data-start=\"516\" data-end=\"530\"\u003ePoE Watchdog\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"533\" data-end=\"552\"\u003e\n\u003cp data-start=\"535\" data-end=\"552\"\u003eLong-Distance PoE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"553\" data-end=\"603\"\u003e\n\u003cp data-start=\"555\" data-end=\"603\"\u003e\u003cstrong data-start=\"555\" data-end=\"586\"\u003eWide operating temperature:\u003c\/strong\u003e –10 °C to +55 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"604\" data-end=\"660\"\u003e\n\u003cp data-start=\"606\" data-end=\"660\"\u003eSupports \u003cstrong data-start=\"615\" data-end=\"634\"\u003eVLAN, STP, RSTP\u003c\/strong\u003e, and \u003cstrong data-start=\"640\" data-end=\"660\"\u003elink aggregation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"661\" data-end=\"734\"\u003e\n\u003cp data-start=\"663\" data-end=\"734\"\u003e\u003cstrong data-start=\"663\" data-end=\"678\"\u003eWeb-managed\u003c\/strong\u003e and \u003cstrong data-start=\"683\" data-end=\"715\"\u003ecentralised cloud management\u003c\/strong\u003e via \u003cstrong data-start=\"720\" data-end=\"734\"\u003eDoLynk App\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"735\" data-end=\"804\"\u003e\n\u003cp data-start=\"737\" data-end=\"804\"\u003eEasy configuration with \u003cstrong data-start=\"761\" data-end=\"804\"\u003eauto network detection and system setup\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"735\" data-end=\"804\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0047\/9510\/5391\/files\/DH-CS4010-8GT-110_V2_datasheet_20251104.pdf?v=1765923577\"\u003e\u003cstrong data-start=\"761\" data-end=\"804\"\u003eDatasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"806\" data-end=\"809\"\u003e\n\u003ch2 data-start=\"811\" data-end=\"834\"\u003eBasic Specifications\u003c\/h2\u003e\n\u003cul data-start=\"835\" data-end=\"946\"\u003e\n\u003cli data-start=\"835\" data-end=\"867\"\u003e\n\u003cp data-start=\"837\" data-end=\"867\"\u003e\u003cstrong data-start=\"837\" data-end=\"857\"\u003eSwitching Layer:\u003c\/strong\u003e Layer 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"868\" data-end=\"903\"\u003e\n\u003cp data-start=\"870\" data-end=\"903\"\u003e\u003cstrong data-start=\"870\" data-end=\"893\"\u003eSwitching Capacity:\u003c\/strong\u003e 20 Gbps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"904\" data-end=\"946\"\u003e\n\u003cp data-start=\"906\" data-end=\"946\"\u003e\u003cstrong data-start=\"906\" data-end=\"933\"\u003ePacket Forwarding Rate:\u003c\/strong\u003e 14.88 Mpps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"948\" data-end=\"951\"\u003e\n\u003ch2 data-start=\"953\" data-end=\"974\"\u003ePort Configuration\u003c\/h2\u003e\n\u003cul data-start=\"975\" data-end=\"1090\"\u003e\n\u003cli data-start=\"975\" data-end=\"1026\"\u003e\n\u003cp data-start=\"977\" data-end=\"1026\"\u003e\u003cstrong data-start=\"977\" data-end=\"991\"\u003ePorts 1–8:\u003c\/strong\u003e 8 × RJ-45 10\/100\/1000 Mbps (PoE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1027\" data-end=\"1090\"\u003e\n\u003cp data-start=\"1029\" data-end=\"1090\"\u003e\u003cstrong data-start=\"1029\" data-end=\"1044\"\u003ePorts 9–10:\u003c\/strong\u003e 2 × RJ-45 10\/100\/1000 Mbps (Gigabit uplink)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1092\" data-end=\"1095\"\u003e\n\u003ch2 data-start=\"1097\" data-end=\"1128\"\u003eEnvironmental Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1129\" data-end=\"1371\"\u003e\n\u003cli data-start=\"1129\" data-end=\"1196\"\u003e\n\u003cp data-start=\"1131\" data-end=\"1196\"\u003e\u003cstrong data-start=\"1131\" data-end=\"1157\"\u003eOperating Temperature:\u003c\/strong\u003e –10 °C to +55 °C (+14 °F to +131 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1197\" data-end=\"1252\"\u003e\n\u003cp data-start=\"1199\" data-end=\"1252\"\u003e\u003cstrong data-start=\"1199\" data-end=\"1222\"\u003eOperating Humidity:\u003c\/strong\u003e 10%–90% RH (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1253\" data-end=\"1318\"\u003e\n\u003cp data-start=\"1255\" data-end=\"1318\"\u003e\u003cstrong data-start=\"1255\" data-end=\"1279\"\u003eStorage Temperature:\u003c\/strong\u003e –40 °C to +75 °C (–40 °F to +167 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1319\" data-end=\"1371\"\u003e\n\u003cp data-start=\"1321\" data-end=\"1371\"\u003e\u003cstrong data-start=\"1321\" data-end=\"1342\"\u003eStorage Humidity:\u003c\/strong\u003e 5%–95% RH (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1373\" data-end=\"1376\"\u003e\n\u003ch2 data-start=\"1378\" data-end=\"1386\"\u003ePower\u003c\/h2\u003e\n\u003cul data-start=\"1387\" data-end=\"1516\"\u003e\n\u003cli data-start=\"1387\" data-end=\"1448\"\u003e\n\u003cp data-start=\"1389\" data-end=\"1448\"\u003e\u003cstrong data-start=\"1389\" data-end=\"1406\"\u003ePower Supply:\u003c\/strong\u003e External power adapter, 54 VDC \/ 2.22 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1449\" data-end=\"1516\"\u003e\n\u003cp data-start=\"1451\" data-end=\"1475\"\u003e\u003cstrong data-start=\"1451\" data-end=\"1473\"\u003ePower Consumption:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1478\" data-end=\"1516\"\u003e\n\u003cli data-start=\"1478\" data-end=\"1493\"\u003e\n\u003cp data-start=\"1480\" data-end=\"1493\"\u003eIdle: 5.7 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1496\" data-end=\"1516\"\u003e\n\u003cp data-start=\"1498\" data-end=\"1516\"\u003eFull Load: 115 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1518\" data-end=\"1521\"\u003e\n\u003ch2 data-start=\"1523\" data-end=\"1544\"\u003ePoE Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1545\" data-end=\"2096\"\u003e\n\u003cli data-start=\"1545\" data-end=\"1569\"\u003e\n\u003cp data-start=\"1547\" data-end=\"1569\"\u003e\u003cstrong data-start=\"1547\" data-end=\"1563\"\u003ePoE Support:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1570\" data-end=\"1644\"\u003e\n\u003cp data-start=\"1572\" data-end=\"1644\"\u003e\u003cstrong data-start=\"1572\" data-end=\"1590\"\u003ePoE Protocols:\u003c\/strong\u003e IEEE 802.3af \/ IEEE 802.3at \/ Hi-PoE \/ IEEE 802.3bt\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1645\" data-end=\"1772\"\u003e\n\u003cp data-start=\"1647\" data-end=\"1670\"\u003e\u003cstrong data-start=\"1647\" data-end=\"1668\"\u003ePoE Output Power:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1673\" data-end=\"1772\"\u003e\n\u003cli data-start=\"1673\" data-end=\"1703\"\u003e\n\u003cp data-start=\"1675\" data-end=\"1703\"\u003ePorts 1–2: ≤ 90 W per port\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1706\" data-end=\"1736\"\u003e\n\u003cp data-start=\"1708\" data-end=\"1736\"\u003ePorts 3–8: ≤ 30 W per port\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1739\" data-end=\"1772\"\u003e\n\u003cp data-start=\"1741\" data-end=\"1772\"\u003e\u003cstrong data-start=\"1741\" data-end=\"1762\"\u003eTotal PoE Budget:\u003c\/strong\u003e ≤ 110 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1773\" data-end=\"1915\"\u003e\n\u003cp data-start=\"1775\" data-end=\"1802\"\u003e\u003cstrong data-start=\"1775\" data-end=\"1800\"\u003ePoE Power Management:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1805\" data-end=\"1915\"\u003e\n\u003cli data-start=\"1805\" data-end=\"1841\"\u003e\n\u003cp data-start=\"1807\" data-end=\"1841\"\u003ePoE power consumption management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1844\" data-end=\"1864\"\u003e\n\u003cp data-start=\"1846\" data-end=\"1864\"\u003ePoE power on\/off\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1867\" data-end=\"1915\"\u003e\n\u003cp data-start=\"1869\" data-end=\"1915\"\u003eAutomatic PoE shutdown on overload detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1916\" data-end=\"2065\"\u003e\n\u003cp data-start=\"1918\" data-end=\"1943\"\u003e\u003cstrong data-start=\"1918\" data-end=\"1941\"\u003ePoE Pin Assignment:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1946\" data-end=\"2065\"\u003e\n\u003cli data-start=\"1946\" data-end=\"2010\"\u003e\n\u003cp data-start=\"1948\" data-end=\"1964\"\u003e\u003cstrong data-start=\"1948\" data-end=\"1962\"\u003ePorts 1–2:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1969\" data-end=\"2010\"\u003e\n\u003cli data-start=\"1969\" data-end=\"1987\"\u003e\n\u003cp data-start=\"1971\" data-end=\"1987\"\u003eV+: 1, 2, 4, 5\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1992\" data-end=\"2010\"\u003e\n\u003cp data-start=\"1994\" data-end=\"2010\"\u003eV–: 3, 6, 7, 8\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2013\" data-end=\"2065\"\u003e\n\u003cp data-start=\"2015\" data-end=\"2031\"\u003e\u003cstrong data-start=\"2015\" data-end=\"2029\"\u003ePorts 3–8:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2036\" data-end=\"2065\"\u003e\n\u003cli data-start=\"2036\" data-end=\"2048\"\u003e\n\u003cp data-start=\"2038\" data-end=\"2048\"\u003eV+: 1, 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2053\" data-end=\"2065\"\u003e\n\u003cp data-start=\"2055\" data-end=\"2065\"\u003eV–: 3, 6\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2066\" data-end=\"2096\"\u003e\n\u003cp data-start=\"2068\" data-end=\"2096\"\u003e\u003cstrong data-start=\"2068\" data-end=\"2090\"\u003eLong-Distance PoE:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2098\" data-end=\"2101\"\u003e\n\u003ch2 data-start=\"2103\" data-end=\"2123\"\u003eHardware Features\u003c\/h2\u003e\n\u003ch3 data-start=\"2124\" data-end=\"2148\"\u003eDIP Switch Functions\u003c\/h3\u003e\n\u003cul data-start=\"2149\" data-end=\"2563\"\u003e\n\u003cli data-start=\"2149\" data-end=\"2243\"\u003e\n\u003cp data-start=\"2151\" data-end=\"2170\"\u003e\u003cstrong data-start=\"2151\" data-end=\"2168\"\u003eManaged Mode:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2173\" data-end=\"2243\"\u003e\n\u003cli data-start=\"2173\" data-end=\"2219\"\u003e\n\u003cp data-start=\"2175\" data-end=\"2219\"\u003eON (default): Local web + cloud management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2222\" data-end=\"2243\"\u003e\n\u003cp data-start=\"2224\" data-end=\"2243\"\u003eOFF: Unmanaged mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2244\" data-end=\"2406\"\u003e\n\u003cp data-start=\"2246\" data-end=\"2265\"\u003e\u003cstrong data-start=\"2246\" data-end=\"2263\"\u003ePoE Watchdog:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2268\" data-end=\"2406\"\u003e\n\u003cli data-start=\"2268\" data-end=\"2290\"\u003e\n\u003cp data-start=\"2270\" data-end=\"2290\"\u003eMonitors ports 1–8\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2293\" data-end=\"2363\"\u003e\n\u003cp data-start=\"2295\" data-end=\"2363\"\u003eAutomatically restarts PoE if no traffic is detected for 2 minutes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2366\" data-end=\"2406\"\u003e\n\u003cp data-start=\"2368\" data-end=\"2406\"\u003e\u003cem data-start=\"2368\" data-end=\"2406\"\u003eOnly active when Managed Mode is OFF\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2407\" data-end=\"2538\"\u003e\n\u003cp data-start=\"2409\" data-end=\"2427\"\u003e\u003cstrong data-start=\"2409\" data-end=\"2425\"\u003eExtend Mode:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2430\" data-end=\"2538\"\u003e\n\u003cli data-start=\"2430\" data-end=\"2495\"\u003e\n\u003cp data-start=\"2432\" data-end=\"2495\"\u003ePorts 1–8 support up to \u003cstrong data-start=\"2456\" data-end=\"2465\"\u003e250 m\u003c\/strong\u003e transmission at \u003cstrong data-start=\"2482\" data-end=\"2493\"\u003e10 Mbps\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2498\" data-end=\"2538\"\u003e\n\u003cp data-start=\"2500\" data-end=\"2538\"\u003e\u003cem data-start=\"2500\" data-end=\"2538\"\u003eOnly active when Managed Mode is OFF\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2540\" data-end=\"2563\"\u003e\n\u003cp data-start=\"2542\" data-end=\"2563\"\u003e\u003cstrong data-start=\"2542\" data-end=\"2559\"\u003eReset Button:\u003c\/strong\u003e 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2565\" data-end=\"2568\"\u003e\n\u003ch2 data-start=\"2570\" data-end=\"2584\"\u003ePerformance\u003c\/h2\u003e\n\u003cul data-start=\"2585\" data-end=\"2736\"\u003e\n\u003cli data-start=\"2585\" data-end=\"2614\"\u003e\n\u003cp data-start=\"2587\" data-end=\"2614\"\u003e\u003cstrong data-start=\"2587\" data-end=\"2596\"\u003eMTBF:\u003c\/strong\u003e 2,482,955 hours\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2615\" data-end=\"2644\"\u003e\n\u003cp data-start=\"2617\" data-end=\"2644\"\u003e\u003cstrong data-start=\"2617\" data-end=\"2635\"\u003ePacket Buffer:\u003c\/strong\u003e 4 Mbit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2645\" data-end=\"2678\"\u003e\n\u003cp data-start=\"2647\" data-end=\"2678\"\u003e\u003cstrong data-start=\"2647\" data-end=\"2663\"\u003eJumbo Frame:\u003c\/strong\u003e 15,360 Bytes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2679\" data-end=\"2708\"\u003e\n\u003cp data-start=\"2681\" data-end=\"2708\"\u003e\u003cstrong data-start=\"2681\" data-end=\"2703\"\u003eMAC Address Table:\u003c\/strong\u003e 8K\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2709\" data-end=\"2736\"\u003e\n\u003cp data-start=\"2711\" data-end=\"2736\"\u003e\u003cstrong data-start=\"2711\" data-end=\"2731\"\u003eSupported VLANs:\u003c\/strong\u003e 32\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2738\" data-end=\"2741\"\u003e\n\u003ch2 data-start=\"2743\" data-end=\"2763\"\u003eNetwork Standards\u003c\/h2\u003e\n\u003cul data-start=\"2764\" data-end=\"2897\"\u003e\n\u003cli data-start=\"2764\" data-end=\"2897\"\u003e\n\u003cp data-start=\"2766\" data-end=\"2787\"\u003e\u003cstrong data-start=\"2766\" data-end=\"2785\"\u003eIEEE Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2790\" data-end=\"2897\"\u003e\n\u003cli data-start=\"2790\" data-end=\"2804\"\u003e\n\u003cp data-start=\"2792\" data-end=\"2804\"\u003eIEEE 802.3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2807\" data-end=\"2822\"\u003e\n\u003cp data-start=\"2809\" data-end=\"2822\"\u003eIEEE 802.3u\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2825\" data-end=\"2840\"\u003e\n\u003cp data-start=\"2827\" data-end=\"2840\"\u003eIEEE 802.3x\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2843\" data-end=\"2859\"\u003e\n\u003cp data-start=\"2845\" data-end=\"2859\"\u003eIEEE 802.3ab\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2862\" data-end=\"2878\"\u003e\n\u003cp data-start=\"2864\" data-end=\"2878\"\u003eIEEE 802.3az\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2881\" data-end=\"2897\"\u003e\n\u003cp data-start=\"2883\" data-end=\"2897\"\u003eIEEE 802.3ad\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2899\" data-end=\"2902\"\u003e\n\u003ch2 data-start=\"2904\" data-end=\"2923\"\u003eNetwork Features\u003c\/h2\u003e\n\u003cul data-start=\"2924\" data-end=\"3394\"\u003e\n\u003cli data-start=\"2924\" data-end=\"2967\"\u003e\n\u003cp data-start=\"2926\" data-end=\"2967\"\u003e\u003cstrong data-start=\"2926\" data-end=\"2955\"\u003eEthernet Loop Protection:\u003c\/strong\u003e STP, RSTP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2968\" data-end=\"2998\"\u003e\n\u003cp data-start=\"2970\" data-end=\"2998\"\u003e\u003cstrong data-start=\"2970\" data-end=\"2979\"\u003eVLAN:\u003c\/strong\u003e IEEE 802.1Q VLAN\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2999\" data-end=\"3043\"\u003e\n\u003cp data-start=\"3001\" data-end=\"3043\"\u003e\u003cstrong data-start=\"3001\" data-end=\"3022\"\u003eLink Aggregation:\u003c\/strong\u003e Static aggregation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3044\" data-end=\"3238\"\u003e\n\u003cp data-start=\"3046\" data-end=\"3066\"\u003e\u003cstrong data-start=\"3046\" data-end=\"3064\"\u003ePort Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3069\" data-end=\"3238\"\u003e\n\u003cli data-start=\"3069\" data-end=\"3097\"\u003e\n\u003cp data-start=\"3071\" data-end=\"3097\"\u003eIEEE 802.3x Flow Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3100\" data-end=\"3131\"\u003e\n\u003cp data-start=\"3102\" data-end=\"3131\"\u003eUnknown Unicast Suppression\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3134\" data-end=\"3161\"\u003e\n\u003cp data-start=\"3136\" data-end=\"3161\"\u003eMulticast Storm Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3164\" data-end=\"3191\"\u003e\n\u003cp data-start=\"3166\" data-end=\"3191\"\u003eBroadcast Storm Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3194\" data-end=\"3216\"\u003e\n\u003cp data-start=\"3196\" data-end=\"3216\"\u003eMAC + Port Binding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3219\" data-end=\"3238\"\u003e\n\u003cp data-start=\"3221\" data-end=\"3238\"\u003eLoop Prevention\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3239\" data-end=\"3309\"\u003e\n\u003cp data-start=\"3241\" data-end=\"3262\"\u003e\u003cstrong data-start=\"3241\" data-end=\"3260\"\u003ePort Mirroring:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3265\" data-end=\"3309\"\u003e\n\u003cli data-start=\"3265\" data-end=\"3289\"\u003e\n\u003cp data-start=\"3267\" data-end=\"3289\"\u003eLocal Port Mirroring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3292\" data-end=\"3309\"\u003e\n\u003cp data-start=\"3294\" data-end=\"3309\"\u003eN:1 Mirroring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3310\" data-end=\"3335\"\u003e\n\u003cp data-start=\"3312\" data-end=\"3335\"\u003e\u003cstrong data-start=\"3312\" data-end=\"3329\"\u003eLLDP Support:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3336\" data-end=\"3361\"\u003e\n\u003cp data-start=\"3338\" data-end=\"3361\"\u003e\u003cstrong data-start=\"3338\" data-end=\"3347\"\u003eDHCP:\u003c\/strong\u003e DHCP Client\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3362\" data-end=\"3394\"\u003e\n\u003cp data-start=\"3364\" data-end=\"3394\"\u003e\u003cstrong data-start=\"3364\" data-end=\"3377\"\u003eSecurity:\u003c\/strong\u003e Port Isolation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3396\" data-end=\"3399\"\u003e\n\u003ch2 data-start=\"3401\" data-end=\"3414\"\u003eManagement\u003c\/h2\u003e\n\u003cul data-start=\"3415\" data-end=\"3550\"\u003e\n\u003cli data-start=\"3415\" data-end=\"3486\"\u003e\n\u003cp data-start=\"3417\" data-end=\"3442\"\u003e\u003cstrong data-start=\"3417\" data-end=\"3440\"\u003eManagement Methods:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3445\" data-end=\"3486\"\u003e\n\u003cli data-start=\"3445\" data-end=\"3463\"\u003e\n\u003cp data-start=\"3447\" data-end=\"3463\"\u003eWeb Management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3466\" data-end=\"3486\"\u003e\n\u003cp data-start=\"3468\" data-end=\"3486\"\u003eCloud Management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3487\" data-end=\"3550\"\u003e\n\u003cp data-start=\"3489\" data-end=\"3520\"\u003e\u003cstrong data-start=\"3489\" data-end=\"3518\"\u003eMonitoring \u0026amp; Maintenance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3523\" data-end=\"3550\"\u003e\n\u003cli data-start=\"3523\" data-end=\"3531\"\u003e\n\u003cp data-start=\"3525\" data-end=\"3531\"\u003eLogs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3534\" data-end=\"3550\"\u003e\n\u003cp data-start=\"3536\" data-end=\"3550\"\u003eFault Alarms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3552\" data-end=\"3555\"\u003e\n\u003ch2 data-start=\"3557\" data-end=\"3570\"\u003eProtection\u003c\/h2\u003e\n\u003cul data-start=\"3571\" data-end=\"3734\"\u003e\n\u003cli data-start=\"3571\" data-end=\"3650\"\u003e\n\u003cp data-start=\"3573\" data-end=\"3594\"\u003e\u003cstrong data-start=\"3573\" data-end=\"3592\"\u003eESD Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3597\" data-end=\"3650\"\u003e\n\u003cli data-start=\"3597\" data-end=\"3620\"\u003e\n\u003cp data-start=\"3599\" data-end=\"3620\"\u003eAir Discharge: 8 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3623\" data-end=\"3650\"\u003e\n\u003cp data-start=\"3625\" data-end=\"3650\"\u003eContact Discharge: 6 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3651\" data-end=\"3734\"\u003e\n\u003cp data-start=\"3653\" data-end=\"3680\"\u003e\u003cstrong data-start=\"3653\" data-end=\"3678\"\u003eLightning Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3683\" data-end=\"3734\"\u003e\n\u003cli data-start=\"3683\" data-end=\"3704\"\u003e\n\u003cp data-start=\"3685\" data-end=\"3704\"\u003eCommon Mode: 6 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3707\" data-end=\"3734\"\u003e\n\u003cp data-start=\"3709\" data-end=\"3734\"\u003eDifferential Mode: 1 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3736\" data-end=\"3739\"\u003e\n\u003ch2 data-start=\"3741\" data-end=\"3767\"\u003ePhysical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"3768\" data-end=\"4041\"\u003e\n\u003cli data-start=\"3768\" data-end=\"3805\"\u003e\n\u003cp data-start=\"3770\" data-end=\"3805\"\u003e\u003cstrong data-start=\"3770\" data-end=\"3785\"\u003eNet Weight:\u003c\/strong\u003e 0.36 kg (0.79 lb)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3806\" data-end=\"3845\"\u003e\n\u003cp data-start=\"3808\" data-end=\"3845\"\u003e\u003cstrong data-start=\"3808\" data-end=\"3825\"\u003eGross Weight:\u003c\/strong\u003e 1.13 kg (2.49 lb)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3846\" data-end=\"3925\"\u003e\n\u003cp data-start=\"3848\" data-end=\"3873\"\u003e\u003cstrong data-start=\"3848\" data-end=\"3871\"\u003eProduct Dimensions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3876\" data-end=\"3925\"\u003e\n\u003cli data-start=\"3876\" data-end=\"3925\"\u003e\n\u003cp data-start=\"3878\" data-end=\"3925\"\u003e184.6 × 103.3 × 27 mm (7.27\" × 4.07\" × 1.06\")\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3926\" data-end=\"4004\"\u003e\n\u003cp data-start=\"3928\" data-end=\"3955\"\u003e\u003cstrong data-start=\"3928\" data-end=\"3953\"\u003ePackaging Dimensions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3958\" data-end=\"4004\"\u003e\n\u003cli data-start=\"3958\" data-end=\"4004\"\u003e\n\u003cp data-start=\"3960\" data-end=\"4004\"\u003e252 × 137 × 113 mm (9.92\" × 5.39\" × 4.45\")\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4005\" data-end=\"4041\"\u003e\n\u003cp data-start=\"4007\" data-end=\"4041\"\u003e\u003cstrong data-start=\"4007\" data-end=\"4027\"\u003eCasing Material:\u003c\/strong\u003e Sheet metal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4043\" data-end=\"4046\"\u003e\n\u003ch2 data-start=\"4048\" data-end=\"4063\"\u003eInstallation\u003c\/h2\u003e\n\u003cul data-start=\"4064\" data-end=\"4115\"\u003e\n\u003cli data-start=\"4064\" data-end=\"4115\"\u003e\n\u003cp data-start=\"4066\" data-end=\"4115\"\u003e\u003cstrong data-start=\"4066\" data-end=\"4087\"\u003eMounting Options:\u003c\/strong\u003e Desktop mount, Wall mount\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4117\" data-end=\"4120\"\u003e\n\u003ch2 data-start=\"4122\" data-end=\"4139\"\u003eCertifications\u003c\/h2\u003e\n\u003cul data-start=\"4140\" data-end=\"4148\"\u003e\n\u003cli data-start=\"4140\" data-end=\"4148\"\u003e\n\u003cp data-start=\"4142\" data-end=\"4148\"\u003e\u003cstrong data-start=\"4142\" data-end=\"4148\"\u003eCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4150\" data-end=\"4153\"\u003e\n\u003ch2 data-start=\"4155\" data-end=\"4170\"\u003ePacking List\u003c\/h2\u003e\n\u003cul data-start=\"4171\" data-end=\"4272\"\u003e\n\u003cli data-start=\"4171\" data-end=\"4190\"\u003e\n\u003cp data-start=\"4173\" data-end=\"4190\"\u003e1 × User Manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4191\" data-end=\"4231\"\u003e\n\u003cp data-start=\"4193\" data-end=\"4231\"\u003e1 × Legal and Regulatory Information\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4232\" data-end=\"4253\"\u003e\n\u003cp data-start=\"4234\" data-end=\"4253\"\u003e1 × Power Adapter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4254\" data-end=\"4272\"\u003e\n\u003cp data-start=\"4256\" data-end=\"4272\"\u003e1 × Power Cord\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 3 Year Dahua ANZ Manufacturer Warranty\u003c\/p\u003e"}
Translation missing: en.products.product.regular_price $162.76